SHARP simulation of discontinuities in highly convective steady flow

For steady multidimesional convection, the Quadratic Upstream Interpolation for Convective Kinematics (QUICK) scheme has several attractive properties. However, for highly convective simulation of step profiles, QUICK produces unphysical overshoots and a few oscillations, and this may cause serious problems in nonlinear flows. Fortunately, it is possible to modify the convective flux by writing the normalized convected control-volume face value as a function of the normalized adjacent upstream node value, developing criteria for monotonic resolution without sacrificing formal accuracy. This results in a nonlinear functional relationship between the normalized variables, whereas standard methods are all linear in this sense. The resulting Simple High Accuracy Resolution Program (SHARP) can be applied to steady multidimensional flows containing thin shear or mixing layers, shock waves, and other frontal phenomena. This represents a significant advance in modeling highly convective flows of engineering and geophysical importance. SHARP is based on an explicit, conservative, control-volume flux formation, equally applicable to one, two, or three dimensional elliptic, parabolic, hyperbolic, or mixed-flow regimes. Results are given for the bench-mark purely convective first-order results and the nonmonotonic predictions of second- and third-order upwinding.

Leonard, B. P.

Pressure difference-flow rate variation in a femoral artery branch casting of man for steady flow

In-vitro, steady flow in a casting of the profunda femoris branch of the femoral artery of man was studied by measuring pressure differences in the main lumen and also in the branch over a large Reynolds number range from 200 to 1600. Effects of viscous and inviscid flows in this femoral artery branch were demonstrated quantitatively. The critical ratio of the flow rate in the branch to the upstream main lumen in this casting was found to be 0.4, above which the inviscid flow analysis indicated a pressure rise and below which it yielded a pressure drop in the main lumen across the branch junction. Pressure rises were experimentally found to occur both in the main lumen and in the branch for certain ranges of the aforementioned ratio.

Cho, Y. I.

Fluid dynamic study in a femoral artery branch casting of man with upstream main lumen curvature for steady flow

An in-vitro, steady flow investigation was conducted in a hollow, transparent vascular replica of the profunda femoris branch of man for a range of physiological flow conditions. The replica casting tested was obtained from a human cadaver and indicated some plague formation along the main lumen and branch. The flow visualization observations and measured pressure distributions indicated the highly three-dimensional flow characteristics with arterial curvature and branching, and the important role of centrifugal effects in fluid transport mechanisms.

Cho, Y. I.

Steady flow approximations to the helium r-process

A steady flow approximation to the r-process is presented and used for numerical experiments with physical quantities to determine the sensitivity of the process to variations in those quantities. The effect of neutron capture cross sections along the capture path and of recently available improved beta decay rates on the r-process are discussed. The peaks in the observed r-process yield curve near mass numbers 80 and 130 are roughly characterized by a neutron number density of 10 to the 20th per cu/cm; the mean beta decay rates are about 10/s, and the freezing time is comparable to or less than 0.1 s. The peak near mass number 195 is roughly characterized by a neutron number density of 10 to the 21st/cm, the mean beta decay rates are about 100/s, and the freezing time is comparable to or less than 0.01 s. The flow path of the steady state r-process is sensitively dependent upon the neutron capture cross sections in the flow network and on the values of the beta decay rates.

Cameron, A. G. W.

Steady flows at the top of the core from geomagnetic field models - The steady motions theorem

It is demonstrated that the steady tangential velocity at the closed surface of a perfect-fluid conductor bounded by a rigid impenetrable exterior can be uniquely determined from knowledge of the normal component of the time-varying magnetic-flux density on the surface. In the context of a simple earth model consisting of an electrically insulating mantle surrounding a perfectly conducting core, the assumption of steady flow provides enough extra information to eliminate the toroidal ambiguity and to allow derivation of a unique global flow at the top of the core from a model of the geomagnetic field.

Voorhies, C. V.

Steady flows in the solar transition region observed with SMM

Steady flows in the quiet solar transition region have been observed with the Ultraviolet Spectrometer and Polarimeter experiment on the Solar Maximum Mission (SMM) satellite. The persistent vertical motions seen at disk center have spatial rms amplitudes of 1.4 km/s in the C II line, 3.9 km/s in Si IV, and 4.2 km/s in C IV. The amplitudes of the more horizontal flows seen toward the limb tend to be somewhat higher. Plots of steady vertical velocity versus intensity seen at disk center in Si IV and C IV show two distinct branches.

Gebbie, K. B.

A spherical harmonic decomposition technique for analysing steady photospheric flows

Steady flows in the photosphere, including differential rotation, meridional circulation and convection, can be represented by a spectrum of modes. A technique is described in which the spherical harmonic functions are used to determine the characteristics of this spectrum and the nature of these flows. Some information about the spectrum is lost because only one hemisphere is seen, only the line of sight velocity is measured and the measurements contain noise. This produces an apparent mixing between spectral modes. By analyzing synthetic data it is found that, in spite of this mixing, differential rotation can be accurately measured, meridional circulations with small amplitudes can be extracted from the data and giant cells might be separated from supergranules.

Hathaway, David H.

A technique for measurement of instantaneous heat transfer in steady-flow ambient-temperature facilities

An experimental technique is described for obtaining time-resolved heat flux measurements with high-frequency response (up to 100 kHz) in a steady-flow ambient-temperature facility. The heat transfer test object is preheated and suddenly injected into an established steady flow. Thin-film gages deposited on the test surface detect the unsteady substrate surface temperature. Analog circuitry designed for use in short-duration facilities and based on one-dimensional semiinfinite heat conduction is used to perform the temperature/heat flux transformation. A detailed description of substrate properties, instrumentation, experimental procedure, and data reduction is given, along with representative results obtained in the stagnation region of a circular cylinder subjected to a wake-dominated unsteady flow. An in-depth discussion of related work is also provided.

O'Brien, James E.

A simple apparatus for the experimental study of non-steady flow thrust-augmenter ejector configurations

A flexible, and easily modified, test rig is described which allows a one dimensional nonsteady flow stream to be generated, economically from a steady flow source of compressed air. This nonsteady flow is used as the primary stream in a nonsteady flow ejector constituting part of the test equipment. Standard piezo-electric pressure transducers etc. allow local pressures to be studied, as functions of time, in both the primary and secondary (mixed) flow portions of the apparatus. Provision is also made for measuring the primary and secondary mass flows and the thrust generated. Sample results obtained with the equipment are presented.

Khare, J. M.

Calculation of three-dimensional, inviscid supersonic, steady flows

A numerical technique is described for the calculation of three dimensional, inviscid, supersonic, steady flows over wing-body configurations. A high degree of accuracy without increasing the number of computational nodes is obtained by means of a powerful conformal mapping technique. Results are presented for some simple body configurations and for a more complex arrow wing airframe. The numerical results show good agreement with experimental measurements.

Moretti, G.

Transport of energy by disturbances in arbitrary steady flows

An exact equation governing the transport of energy associated with disturbances in an arbitrary steady flow is derived. The result is a generalization of the familiar concept of acoustic energy and is suggested by a perturbation expansion of the general energy equation of fluid mechanics. A disturbance energy density and flux are defined and identified as exact fluid dynamic quantities whose leading-order regular perturbation representations reduce in various special cases to previously known results. The exact equation on disturbance energy is applied to a simple example of nonlinear wave propagation as an illustration of its general utility in situations where a linear description of the disturbance is inadequate.

Myers, M. K.

Calculation of three-dimensional, inviscid, supersonic, steady flows

A detailed description of a computational program for the evaluation of three dimensional supersonic, inviscid, steady flow past airplanes is presented. Emphasis was put on how a powerful, automatic mapping technique is coupled to the fluid mechanical analysis. Each of the three constituents of the analysis (body geometry, mapping technique, and gas dynamical effects) was carefully coded and described. Results of computations based on sample geometrics and discussions are also presented.

Moretti, G.