Simulation of a main steam line break with steam generator tube rupture using trace

A simulation of the OECD/NEA ROSA-2 Project Test 5 was made with the thermal-hydraulic code TRACE5. Test 5 performed in the Large Scale Test Facility (LSTF) reproduced a Main Steam Line Break (MSLB) with a Steam Generator Tube Rupture (SGTR) in a Pressurized Water Reactor (PWR). The result of these simultaneous breaks is a depressurization in the secondary and primary system in loop B because both systems are connected through the SGTR. Good approximation was obtained between TRACE5 results and experimental data. TRACE5 reproduces qualitatively the phenomena that occur in this transient: primary pressure falls after the break, stagnation of the pressure after the opening of the relief valve of the intact steam generator, the pressure falls after the two openings of the PORV and the recovery of the liquid level in the pressurizer after each closure of the PORV. Furthermore, a sensitivity analysis has been performed to know the effect of varying the High Pressure Injection (HPI) flow rate in both loops on the system pressures evolution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental study on the guillotine break accident of the main steam line with Atlas

A main steam line break (MSLB) accident is defined as a pipe break in the main steam system of a nuclear power plant. The MSLB accident is characterized as cool-down event due to the increased steam flow rate, which causes excessive energy removal from the steam generators and eventually reactor coolant system. This results in a decrease in reactor coolant temperature. The cool-down causes an increase in core reactivity due to the negative moderator and Doppler reactivity coefficients. The thermalhydraulic integral effect test was performed to simulate a double-ended guillotine break accident of the main steam line of a pressurized water reactor. With an aim of simulating the MSLB accident as realistically as possible, a pertinent scaling approach was taken, especially focusing on a break flow. The main objectives of this test were not only to provide physical insight into the system response of a nuclear power plant during the MSLB accident but also to produce an integral effect test data to validate the safety analysis codes. In the present test, asymmetric thermal-hydraulic behavior was clearly observed between the loops. In the cold leg-1A and -1B where the affected steam generator is connected, the flow rates were higher and the fluid temperatures were lower than those in the cold leg-2A and -2B. This could be attributed to the excessive heat removal in the cold leg-1A and -1B through the affected steam generator. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes. Furthermore, this data can be utilized to identify any code deficiency for a MSLB simulation, especially for DVI-adapted plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DNB evaluation of PWR steam-line break event using Westinghouse and CASL coupled code systems

ANCKVIPRE and the VERA-CS code systems have been successfully applied to predicting PWR core response with respect to departure from nucleate boiling (DNB) at the limiting time step of a postulated hot zero power (HZP) main steam-line break (MSLB) event with and without offsite power available. ANCKVIPRE links the ANC code with the VIPRE-W code. ANC is Westinghouse's multi-dimensional nodal diffusion code for all nuclear core design calculations. It predicts core reactivity, assembly power, rod power, detector thimble flux, and other relevant core characteristics. VIPRE-W is the Westinghouse version of a thermalhydraulic subchannel code developed for light water reactor core design applications. The reactor core simulation was based on input of the core boundary conditions from RETRAN system transient and STAR-CCM+ CFD core inlet distribution calculations. To account for the asymmetric power distribution in the reactor core due to the broken steam pipe in one loop and the stuck RCCA, both ANCKVIPRE and the VERA-CS models were set up for the whole reactor core. The advanced modeling and simulations confirmed that the HZP MSLB high-flow case with offsite power available is more limiting with respect to the DNB acceptance criterion, consistent with the limiting case analyzed in the 4-loop plant Safety Analysis Report (SAR). The results also demonstrated that the currently NRC-approved Westinghouse coupled code system such as ANCKVIPRE remains conservative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Best estimate plus uncertainty analysis of departure from nucleate boiling limiting case with CASL core simulator VERA-CS in response to PWR main steam line break event

VERA-CS (Virtual Environment for Reactor Applications, Core Simulator) is a coupled neutron transport and thermal-hydraulics subchannel code under development by the Consortium for Advanced Simulation of Light Water Reactors (CASL). VERA-CS was used to simulate a typical pressurized water reactor (PWR) full core response with 17x17 fuel assemblies for a main steam line break (MSLB) accident scenario with the most reactive rod cluster control assembly stuck out of the core. The accident scenario was initiated at the hot zero power (HZP) at the end of the first fuel cycle with return to power state points that were determined by a system analysis code and the most limiting state point was chosen for core analysis. The best estimate plus uncertainty (BEPU) analysis method was applied using Wilks’ nonparametric statistical approach. In this way, 59 full core simulations were performed to provide the minimum departure from nucleate boiling ratio (MDNBR) at the 95/95 (95% probability with 95% confidence level) tolerance limit. The results show that this typical PWR core remains within MDNBR safety limits for the MSLB accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

VERA-CS Modeling and Simulation of PWR Main Steam Line Break Core Response to DNB

The Virtual Environment for Reactor Applications core simulator (VERA-CS) being developed by the Consortium for the Advanced Simulation of Light Water Reactors (CASL) includes coupled neutronics, thermal-hydraulics, and fuel temperature components with an isotopic depletion capability. The neutronics capability employed is based on MPACT, a three-dimensional (3-D) whole core transport code. The thermal-hydraulics and fuel temperature models are provided by the COBRA-TF (CTF) subchannel code. As part of the CASL development program, the VERA-CS (MPACT/CTF) code system was applied to model and simulate reactor core response with respect to departure from nucleate boiling ratio (DNBR) at the limiting time step of a postulated pressurized water reactor (PWR) main steamline break (MSLB) event initiated at the hot zero power (HZP), either with offsite power available and the reactor coolant pumps in operation (high-flow case) or without offsite power where the reactor core is cooled through natural circulation (low-flow case). The VERA-CS simulation was based on core boundary conditions from the RETRAN-02 system transient calculations and STAR-CCM+ computational fluid dynamics (CFD) core inlet distribution calculations. The evaluation indicated that the VERA-CS code system is capable of modeling and simulating quasi-steady state reactor core response under the steamline break (SLB) accident condition, the results are insensitive to uncertainties in the inlet flow distributions from the CFD simulations, and the high-flow case is more DNB limiting than the low-flow case.

CTF↗

Experimental validation on the operational and cooling performance of the passive safety system with Atlas

After the Fukushima accident, passive safety systems are considered as the most promising alternatives to reinforce the safety and reliability of an ultimate heat removal system without any operator actions. In Korea, a passive auxiliary feedwater system (PAFS) was developed and adopted to a GEN-III+ nuclear power plant, APR+ to completely replace the conventional auxiliary feedwater system. The integral effect tests were performed to validate the cooling and operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. The representative design basis accidents (DBAs) such as a feedwater line break, a steam line break, and a steam generator tube rupture transients were experimentally simulated in this study. In addition, an integral effect test was performed for simulating a station blackout transient as a limiting beyond DBA. From the integral effect test results, it could be concluded that the APR+ has the capability of coping with the hypothetical DBA and bDBA by adopting PAFS and proper set-points of its operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Evaluation of Radioactive Aerosol Precipitation on the Inner Surfaces of Steam-Water Lines in Beyond Design Basis Accidents at NPP with RBMK

The results of modeling performed with the MELCOR code of the transport and precipitation of fission product aerosols in the steam-water lines of RBMK during beyond design basis accidents are presented. It is shown that the precipitation of fission product aerosols on the inner surfaces of steam-water lines depends on the course of the accident and can be an effective mechanism for lowering their atmospheric emissions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wireless Sensing, Monitoring and Optimization for Campus-Wide Steam Distribution

The US Congress has passed legislation dictating that all government agencies establish a plan and process for improving energy efficiencies at their sites. In response to this legislation, Oak Ridge National Laboratory (ORNL) has recently conducted a pilot study to explore the deployment of a wireless sensor system for a real-time measurement-based energy efficiency optimization. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize energy delivery within the steam distribution system. Our approach leverages an integrated wireless sensor and real-time monitoring capability. We make real time state assessment on the steam trap health and steam flow estimate of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observing measurements of these sensors with state estimators for system health. Our assessments are based on a spectral-based energy signature scheme that interprets acoustic vibration sensor data to estimate steam flow rates and assess steam traps status. Experimental results show that the energy signature scheme has the potential to identify different steam trap states and it has sufficient sensitivity to estimate flow rate. Moreover, results indicate a nearly quadratic relationship over the test region between the overall energy signature factor and flow rate in the pipe. We are able to present the steam flow and steam trap status, sensor readings, and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. The goal is to achieve significant energy-saving in steam lines by monitoring and acting on leaking steam pipes/traps/valves. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Steam distribution and energy delivery optimization using wireless sensors

The Extreme Measurement Communications Center at Oak Ridge National Laboratory (ORNL) explores the deployment of a wireless sensor system with a real-time measurement-based energy efficiency optimization framework in the ORNL campus. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize the energy delivery within the steam distribution system. We address the goal of achieving significant energy-saving in steam lines by monitoring and acting on leaking steam valves/traps. Our approach leverages an integrated wireless sensor and real-time monitoring capabilities. We make assessments on the real-time status of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observe the state measurements of these sensors. Our assessments are based on analysis of the wireless sensor measurements. We describe Fourier-spectrum based algorithms that interpret acoustic vibration sensor data to characterize flows and classify the steam system status. We are able to present the sensor readings, steam flow, steam trap status and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗

An Energy Signature Scheme for Steam Trap Assessment and Flow Rate Estimation Using Pipe-Induced Acoustic Measurements

The US Congress has passed legislation dictating that all government agencies establish a plan and process for improving energy efficiencies at their sites. In response to this legislation, Oak Ridge National Laboratory (ORNL) has recently conducted a pilot study to explore the deployment of a wireless sensor system for a real-time measurement-based energy efficiency optimization framework within the steam distribution system within the ORNL campus. We make assessments on the real-time status of the distribution system by observing the state measurements of acoustic sensors mounted on the steam pipes/traps/valves. In this paper, we describe a spectral-based energy signature scheme that interprets acoustic vibration sensor data to estimate steam flow rates and assess steam traps health status. Experimental results show that the energy signature scheme has the potential to identify different steam trap health status and it has sufficient sensitivity to estimate steam flow rate. Moreover, results indicate a nearly quadratic relationship over the test region between the overall energy signature factor and flow rate in the pipe. The analysis based on estimated steam flow and steam trap status helps generate alerts that enable operators and maintenance personnel to take remedial action. The goal is to achieve significant energy-saving in steam lines by monitoring and acting on leaking steam pipes/traps/valves.

54 ENVIRONMENTAL SCIENCES↗

A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES

The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoid overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety system components such as the safety relief valve (SRV), the RCIC system, the wet well, and the dry well. The results show reasonable system behaviors while exhibiting rich dynamics such as variable flow rates through RCIC turbine and pump during the SBO transient. The model has the potential to resolve the Fukushima RCIC mystery after adding the off-design two-phase turbine operation model and other additional improvements.

RCIC↗

Molecular phosphorus ion source for semiconductor technology

This paper presents results on the generation of molecular phosphorus ion beams in a hot filament ion source. Solid red phosphorous is evaporated mainly as tetra-atomic molecules up to a temperature of 800 deg. C. Thus, one of the main conditions for producing maximum P{sub 4}{sup +} fraction in the beam is to keep the temperature of the phosphorous oven, the steam line and the discharge chamber walls no greater than 800 deg. C. The prior version of our ion source was equipped with a discharge chamber cooling system. The modified source ensured a P{sub 4}{sup +} ion beam current greater than 30% of the total beam current.

43 PARTICLE ACCELERATORS↗

TRACE Analysis of Loss of Flow for the APR1400

The APR1400 is a pressurized water reactor (PWR). The APR1400 nuclear steam supply system consists of a reactor pressure vessel (RPV), which contains the reactor core, and two primary reactor coolant system loops connected in parallel to the RPV. Each coolant loop consists of a hot leg (HL), a u-tube steam generator (SG), two reactor coolant pumps (RCPs) and two cold legs (CLs). A pressurizer is connected to the hot leg on one of the coolant loops. During normal operation, the RCPs circulate high pressure water through the reactor core to remove the heat. The heated water exits the RPV and passes through the hot legs into the steam generator tubes. Heat is transferred through the walls of the steam generator tubes into a lower pressure secondary coolant system. Cooled primary system water from the steam generators is returned through the RCPs and cold legs to the RPV. The RCPs operate at constant speed; the primary coolant system is designed to provide a prescribed rate of coolant flow through the reactor core. The APR1400 SG secondary coolant system pressure is controlled through modulation of valves in the steam lines to maintain a prescribed turbine inlet pressure. The SG secondary coolant inventory is controlled by using a feedwater control system to maintain a prescribed liquid level in the steam generator downcomer. This water inventory level is sufficient to cover the outer surfaces of the steam generator tubes while preventing overfill that would cause liquid to pass from the steam generators through the steam lines into the turbine system. In the current work, the Nuclear Regulatory Commission's reactor systems analysis code, TRACE?2 was used to perform an analysis of a loss of flow anticipated operational occurrence (AOO). The loss of flow is initiated by a loss of off-site power (LOOP), resulting in a trip of the RCPs. The regulatory purpose of the current work is to confirm safety analyses documented in the APR1400 Design Control Document (DCD)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Release Fractions in Non-LOCA Accidents in Draft Regulatory Guide 1.183, DG-1199

In this note, an argument is made that the non-loss of coolant accident (LOCA) fractions of fission product inventory found within the gap is too high for alkali metals as currently specified within Regulatory Position 3.2 of Draft Regulatory Guide 1.183 rev.1 (DG-1199). This assertion extends to the enthalpy-dependent transient fission product release component used in reactivity initiated accidents. Regulatory Position 3.2 of Draft Regulatory Guide 1.183 rev. 1, which is presented below, details the release fractions of fission product inventory for postulated accident scenarios including both LOCAs and non-LOCA accidents. Relevant non-LOCA accidents include fuel handling accidents, boiling water reactor (BWR) rod drop accidents, pressurized water reactor (PWR) rod ejection accidents, BWR/PWR main steam line breaks, PWR steam generator tube ruptures and PWR locked rotor accidents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗