SEARCH · Search NASA
Results for “STEM (scanning electron emission microscope)”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Advanced Test Reactor National Scientific User Facility: Addressing advanced nuclear materials research
The Advanced Test Reactor National Scientific User Facility (ATR NSUF), based at the Idaho National Laboratory in the United States, is supporting Department of Energy and industry research efforts to ensure the properties of materials in light water reactors are well understood. The ATR NSUF is providing this support through three main efforts: establishing unique infrastructure necessary to conduct research on highly radioactive materials, conducting research in conjunction with industry partners on life extension relevant topics, and providing training courses to encourage more U.S. researchers to understand and address LWR materials issues. In 2010 and 2011, several advanced instruments with capability focused on resolving nuclear material performance issues through analysis on the micro (10-6 m) to atomic (10-10 m) scales were installed primarily at the Center for Advanced Energy Studies (CAES) in Idaho Falls, Idaho. These instruments included a local electrode atom probe (LEAP), a field-emission gun scanning transmission electron microscope (FEG-STEM), a focused ion beam (FIB) system, a Raman spectrometer, and an nanoindentor/atomic force microscope. Ongoing capability enhancements intended to support industry efforts include completion of two shielded, irradiation assisted stress corrosion cracking (IASCC) test loops, the first of which will come online in early calendar year 2013, a pressurized and controlled chemistry water loop for the ATR center flux trap, and a dedicated facility intended to house post irradiation examination equipment. In addition to capability enhancements at the main site in Idaho, the ATR NSUF also welcomed two new partner facilities in 2011 and two new partner facilities in 2012; the Oak Ridge National Laboratory, High Flux Isotope Reactor (HFIR) and associated hot cells and the University California Berkeley capabilities in irradiated materials analysis were added in 2011. In 2012, Purdue University’s Interaction of Materials with Particles and Components Testing (IMPACT) facility and the Pacific Northwest Nuclear Laboratory (PNNL) Radiochemistry Processing Laboratory (RPL) and PIE facilities were added. The ATR NSUF annually hosts a weeklong event called User’s Week in which students and faculty from universities as well as other interested parties from regulatory agencies or industry convene in Idaho Falls, Idaho to see presentations from ATR NSUF staff as well as select researchers from the materials research field. User’s week provides an overview of current materials research topics of interest and an opportunity for young researchers to understand the process of performing work through ATR NSUF. Additionally, to increase the number of researchers engaged in LWR materials issues, a series of workshops are in progress to introduce research staff to stress corrosion cracking, zirconium alloy degradation, and uranium dioxide degradation during in-reactor use.
Method to measure spatial coherence of subangstrom electron beams
A method is described for measuring the intensity distribution of the electron source in a scanning transmission electron microscope (STEM) fitted with an objective lens aberration corrector. The method is applied to a C{sub s}-corrected 300 kV field emission gun TEM/STEM, which is found to have an effective source size of 0.56 A full width at half maximum (FWHM) under optical conditions suitable for high resolution STEM imaging. This corresponds to a probe intensity distribution at the specimen plane of 0.72 A FWHM using a probe-forming aperture of 25 mrad and including the measured residual lens aberrations.
Scanning Electron Microscopy (SEM) Procedure for HE Powders on a Zeiss Sigma HD VP SEM
This method describes the characterization of inert and HE materials by the Zeiss Sigma HD VP field emission Scanning Electron Microscope (SEM). The SEM uses an accelerated electron beam to generate high-magnification images of explosives and other materials. It is fitted with five detectors (SE, Inlens, STEM, VPSE, HDBSD) to enable imaging of the sample via different secondary electron signatures, angles, and energies. In addition to imaging through electron detection, the microscope is also fitted with two Oxford Instrument Energy Dispersive Spectrometer (EDS) 80 mm detectors to generate elemental constituent spectra and two-dimensional maps of the material being scanned.
Characterization of carbon silica hybrid fillers obtained by pyrolysis of waste green tires by the STEM–EDX method
Dual phase carbon–silica hybrid fillers obtained by pyrolysis-cum-water vapor of waste green tires have been characterized by energy dispersive X-ray spectroscopy in a scanning transmission electron microscope, silicate analysis, weight analysis, atomic absorption spectroscopy and by inductively coupled plasma–optical emission spectroscopy. The results achieved have shown that the location and distribution of the phases in the carbon silica hybrid fillers as well as their most essential characteristics are influenced by the pyrolysis conditions. The carbon phase of the filler thus obtained is located predominantly in the space among silica aggregates which have already been existing while it has been formed by elastomer destruction in the course of pyrolysis. The presence of ZnS also has been found in the hybrid fillers investigated. - Highlights: • Dual phase fillers obtained by pyrolysis of waste green tires have been characterized. • The STEM–EDX method was used for characterization. • The phase distributions in the fillers are influenced by the pyrolysis conditions.
Evidence of nanoscale Anderson localization induced by intrinsic compositional disorder in InGaN/GaN quantum wells by scanning tunneling luminescence spectroscopy
We present direct experimental evidence of Anderson localization induced by the intrinsic alloy compositional disorder of InGaN/GaN quantum wells. Our approach relies on the measurement of the luminescence spectrum under local injection of electrons from a scanning tunneling microscope tip into a near-surface single quantum well. Fluctuations in the emission line shape are observed on a few-nanometer scale. Narrow emission peaks characteristic of single localized states are resolved. Calculations in the framework of the localization landscape theory provide the effective confining potential map stemming from composition fluctuations. This theory explains well the observed nanometer scale carrier localization and the energies of these Anderson-type localized states. In conclusion, the energy spreading of the emission from localized states is consistent with the usually observed very broad photo- or electroluminescence spectra of InGaN/GaN quantum well structures.
Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging
Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.
Single atom visibility in STEM optical depth sectioning
The continuing development of aberration correctors for the scanning transmission electron microscope (STEM) offers the possibility of locating single atoms in crystals in 3D via optical depth sectioning. The main factors that determine the feasibility of such an approach are visibility and dose requirements. In this paper, we show how Poisson's statistics can be quantitatively incorporated into STEM image simulations and demonstrate that the 3D location of single cerium atoms in wurtzite-type aluminum nitride is indeed feasible under large-angle illumination conditions with a relatively low dose. We also show that chromatic aberration does not presently represent a limitation provided a cold field emission source is used. Finally, these results suggest efforts into improved aberration corrector designs for larger illumination angles that offer significant potential for 3D structure determination of materials.
Two-dimensional PdSe 2 -Pd 2 Se 3 junctions can serve as nanowires
While the exfoliation of almost all layered materials results in a monolayer with the same atomic geometry as its bulk counterpart, the exfoliation of PdSe 2 results in a monolayer with a different atomic geometry and a new stoichiometry, Pd 2 Se 3 , which is a fusion of two PdSe 2 monolayers mediated by Se emission. Here we first report first-principles calculations of lateral junctions between a PdSe 2 bilayer and a Pd 2 Se 3 monolayer. In this work, we find that, while several distinct junction geometries are possible, they all exhibit empty interface states below the conduction band. As a result, light n-type doping of either or both sides, e.g. by halogen atoms replacing Se atoms, leads to a remotely-doped interface, i.e. a 1D conducting nanowire that runs along the junction, in between the two semiconductors. We have fabricated such junctions inside a scanning transmission electron microscope (STEM), but doping and transport measurements are not currently practical.
Recent Advances in Analytical Electron Microscopy for Irradiated Materials
Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)
Single Particle Cathodoluminescence Spectroscopy with Sub-20 nm, Electron-Stable Phosphors
Lanthanide-doped nanophosphors have emerged as promising optical labels for high-resolution, "multicolor"electron microscopy. Here, we develop a library of 11 unique lanthanide-doped nanophosphors with average edge lengths of 15.2 ± 2.0 nm (N = 4284). These nanophosphors consist of an electron-stable BaYF5 host lattice doped at 25% atomic concentration with the lanthanides Pr 3+ , Nd 3+ , Sm 3+ , Eu 3+ , Tb 3+ , Dy 3+ , Ce 3+ , Ho 3+ , Er 3+ , Tm 3+ , and Yb 3+ . Under ~100 pA/nm 2 beam beam current in a transmission electron microscope, each nanophosphor species exhibits strong cathodoluminescence spectra with sharp characteristic emission lines for each lanthanide. The bright emission and stability of these nanoparticles enable not only ensemble, but also single-particle cathodoluminescence spectroscopy, which we demonstrate with BaYF 5 :Ln 3+ , where Ln 3+ = Tb 3+ , Ho 3+ , Er 3+ , Sm 3+ , Eu 3+ , or Pr 3+ . Single-particle cathodoluminescence corresponds directly with HAADF intensity across nanoparticles, confirming high spatial localization of the measured cathodoluminescence signal of lanthanide-doped nanophosphors. Furthermore, our synthesis and characterization of sub-20 nm, electron-stable nanophosphors provides a robust material platform to achieve single-molecule labeled correlative cathodoluminescence electron microscopy, a critical foundation for high-resolution correlation of single molecules within the context of cellular ultrastructure.