Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUBCOOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of PVD-coated chromium on the subcooled flow boiling performance of nuclear reactor cladding materials

Here we elucidate the separate effect of a thin Cr coating deposited by physical vapor deposition (PVD) on the subcooled flow boiling performance of zircaloy-4. First, we run flow boiling experiments on prototypical zircaloy-4 surfaces mimicking the scratch pattern and surface roughness of nuclear reactor claddings. Then, we PVD-coat a 0.3 µm thick chromium layer on the same exact surface and repeat the same flow boiling investigations. All experiments are run using deionized water at atmospheric pressure, flowing on a 1 × 3 cm 2 rectangular cross section channel at a rate of 1000 kg/m 2 /s and a subcooling of 10 K. We measure the average temperature of the boiling surface at increasing surface heat fluxes, covering a wide range of heat transfer regimes, from single-phase forced convection to the boiling crisis. We also record high-speed videos of the boiling process, which we postprocess to measure bubble nucleation site density, growth time, departure diameter and frequency. The surface analysis reveals that, while the chromium coating does not seem change the surface roughness and morphology, it improves surface wettability. However, it decreases the critical heat flux. The chromium coating causes an increase of nucleation temperature, bubble departure diameter and growth time, and a reduction of the nucleation site density. The concurrence of these observations indicates that a size reduction of the nucleation sites, conformally covered by the chromium coating, may be the cause of the boiling performance deterioration. We confirm this hypothesis repeating the same analysis on a FeCrAl sample prepared and tested using the same protocol as the zircaloy-4 sample, but with a different initial surface texture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Tree-Based Ensemble Learning Models for Wall Temperature Predictions in Post-Critical Heat Flux Flow Regimes at Subcooled and Low-Quality Conditions

Accurately predicting post-critical heat flux (CHF) heat transfer is an important but challenging task in water-cooled reactor design and safety analysis. Although numerous heat transfer correlations have been developed to predict post-CHF heat transfer, these correlations are only applicable to relatively narrow ranges of flow conditions due to the complex physical nature of the post-CHF heat transfer regimes. In this paper, a large quantity of experimental data is collected and summarized from the literature for steady-state subcooled and low-quality film boiling regimes with water as the working fluid in vertical tubular test sections. In addition, a low-quality water film boiling (LWFB) database is consolidated with a total of 22,813 experimental data points, which cover a wide flow range of the system pressure from 0.1 to 9.0 MPa, mass flux from 25 to 2750 kg/m 2 s, and inlet subcooling from 1 to 70 °C. Two machine learning (ML) models, based on random forest (RF) and gradient boosted decision tree (GBDT), are trained and validated to predict wall temperatures in post-CHF flow regimes. The trained ML models demonstrate significantly improved accuracies compared to conventional empirical correlations. To further evaluate the performance of these two ML models from a statistical perspective, three criteria are investigated and three metrics are calculated to quantitatively assess the accuracy of these two ML models. For the full LWFB database, the root-mean-square errors between the measured and predicted wall temperatures by the GBDT and RF models are 5.7% and 6.2%, respectively, confirming the accuracy of the two ML models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Separate Effects Validation for Subcooled Boiling in CTF

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which is focused on developing high-fidelity and high-resolution modeling and simulation (M&S) tools for modeling of light water reactors (LWRs). This hub, the Consortium for Advanced Simulation of LWRs (CASL), has developed an LWR simulation tool called the Virtual Environment for Reactor Applications (VERA). The multi-physics capability of VERA is achieved through the coupling of single-physics codes, including CTF (the CASL version of Coolant Boiling in Rod Arrays— Three Field (COBRA-TF)), Michigan Parallel Characteristics Transport (MPACT), BISON, and Materials Performance and Optimization (MPO) Advanced Model for Boron Analysis (MAMBA). As part of its M&S efforts, CASL has identified various challenge problems, including Crud Induced Power Shift (CIPS), Crud-Induced Localized Corrosion (CILC), Pellet-Cladding Interaction (PCI), and Departure from Nucleate Boiling (DNB). This work addresses CASL milestone L2:VVI.P19.03, which focuses on uncertainty quantification of crud, which is relevant to both CIPS and CILC. This is achieved through an analysis and separate effects validation of the thermal hydraulic phenomenon known as subcooled boiling. As part of this work, various sources of experimental data are examined and compared to different options for empirical modeling of subcooled boiling. Through this analysis, a complete understanding of the underlying models and their implementation details are understood. A subset of these data are incorporated into a separate effects validation study of CTF. The Westinghouse Advanced Loop Tester (WALT) and Rohsenow experiments are modeled, and it is shown that the newly-implemented Gorenflo correlation is more accurate than the existing Chen and Thom correlations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Force Balance Model Assessment for Mechanistic Prediction of Sliding Bubble Velocity in Vertical Subcooled Boiling Flow

The bubble sliding after departing from nucleation site is frequently observed in flow boiling systems and, the crucial impact on wall heat transfer has been evidenced through many experiments. As a result, the heat transfer modeling associated with sliding bubble has become one of the subjects of great attention in CFD boiling heat transfer community. The modeling efforts are primarily aimed at improving the existing Heat Flux Partitioning (HFP) model via the implementation of sliding bubble-induced heat transfer. The performance of HFP model depends inherently on the fidelity of sub-models used to predict the fundamental bubble parameters (e.g., bubble departure/lift-off diameter). In the same context, the accurate prediction of sliding bubble parameters (e.g., sliding bubble growth, sliding bubble velocity) is essential to achieving the successful heat transfer modeling associated with sliding bubble. Of many sliding bubble parameters, this paper deals with the sliding bubble velocity. Specifically, the force balance model was assessed in view of the sliding bubble velocity prediction. The parametric effect of key sub-models (e.g., drag force, bubble growth models) used in the force balance equation was investigated. The experimental data from Maity (2000) and Yoo et al. (2016) were used for demonstrating the model predictive performance. It was found that the force balance model proposed in this study was able to predict well the bubble sliding velocity based on the accurate prediction of bubble growth during sliding. The predictive performance was proven with the experimental data measured under various subcooled boiling conditions of both water and refrigerant (NOVEC-7000) flowing upward in vertical channels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Refrigeration system

In one aspect, a refrigeration system is provided. The refrigeration system includes a refrigeration circuit configured to condition an air supply, a subcooling circuit configured to cool the refrigeration circuit, the subcooling circuit including a subcooling condenser, a subcooling heat exchanger, and at least one adsorption bed, and a heat generation system thermally coupled to the subcooling circuit.

42 ENGINEERING↗

Progress Toward Simulating Departure from Nucleate Boiling at High-Pressure Applications with Selected Wall Boiling Closures

Recently, a Eulerian-based two-fluid computational fluid dynamics (CFD) framework with a wall heat flux partitioning approach has been intensively investigated for departure from nucleate boiling (DNB) simulation under the U.S. Department of Energy–funded Consortium for Advanced Simulation of Light Water Reactors (CASL) program. Understanding of the DNB characteristics over a range of pressurized water reactor–like operating conditions and accurate prediction of boiling crisis in the nuclear power system have been grand challenges because of the large impact of DNB on reactor safety and operational economics. The ultimate goal of this task in the CASL program is to introduce a robust multiphase CFD–based DNB modeling framework that is capable of characterizing an entire boiling history in which the wall boiling mode experiences the following through multiple stages of heat transfer mode: (1) single-phase convective heat transfer, (2) nucleate boiling heat transfer, and (3) identification of the departure of nucleate boiling. To validate the CASL boiling model, we have benchmarked simulated DNB over three different flow channel configurations (pipe flow, 5 × 5 fuel bundle with mixing vane tests, and 5 × 5 fuel bundle without mixing vane tests) against experimental measurements, and the validation result with open literature is reported. The DNB detection criteria in the simulation are checked by monitoring the peak wall temperature, wall dryout factor, and net energy balance. In addition to the DNB performance test, some preliminary sensitivity results on closure model selection are reported to address the prediction capability of local void profile against measurements. The boiling simulation tested in this study exhibits a maximum deviation of 24% from the measured DNB value in a high-pressure (i.e., 138 bars) subcooled pipe flow test. The ranges of operating conditions are as follows: 1650 to 2650 kg/m 2 ·s for mass flux and 8.5 to 96 K for subcooled inlet temperature. The deviation is even reduced to 7% when the subcooled temperature is less than 40 K. Besides accuracy, base practice guidelines for DNB detection criteria are tested by monitoring three simulation variables: (1) maximum wall temperature, (2) wall dryout factor (i.e., K-value), and (3) energy balance. Numerical robustness of DNB simulation is largely achieved in most of the validation test except for a few high subcooled test cases.

42 ENGINEERING↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗