Search NASA⌕ Search

SEARCH · Search NASA

Results for “SURFACE IONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimation of mean electron energy in helium surface ionization waves on dielectric substrates

Abstract The determination of basic plasma parameters in atmospheric pressure discharges is critical to advancing their use in applications. Atmospheric pressure plasma jets have found use in the fields of medicine, agriculture, material modification and others. Atmospheric pressure plasma jets often generate plasma surface ionization waves (SIW) which interact with and propagate over surfaces. Electrical diagnostics are challenging in SIW due to high collision frequencies and small scale of the plasma discharge. This work employs a passive optical emission line ratio technique to estimate the mean electron energy in SIW over planar dielectric substrates. The method uses an intensity ratio of two helium triplet lines: He( 3 3 S ) at 706.5 nm and He( 3 3 D ) at 587.56 nm. A collisional-radiative model is used to correlate line ratio to mean electron energy and determine dependencies on electron density and He/air gas mixture. Mean electron energies ranging from 3–8 eV are determined in He/air mixtures and are found to remain constant as the surface wave propagates radially. This work provides a 2D, time-resolved, mean electron energy diagnostic for surface ionization wave propagation and validation of numerical modeling in atmospheric pressure systems with spatially varying He/air gas mixtures. The model in question is designed for use with any He line ratio in the n = 3 excitation level.

Morsell, Joshua (ORCID:0000000331073002)↗

Permanent Nanobubbles in Water: Liquefied Hollow Carbon Spheres Break the Limiting Diffusion Current of Oxygen Reduction Reaction

Porous liquids have traditionally been designed with sterically hindered solvents. Alternatively, recent efforts rely on dispersing microporous frameworks in simpler solvents like water. Here we report a unique strategy to construct macroporous water by selectively incorporating hydrophilicity on the surfaces of hydrophobic hollow carbon spheres (HCS). Specifically, we show that the stable dispersion surface ionized HCS in water while retaining the inherent porosity. The electrocatalytic conversion of small gas molecules in aqueous electrolytes is limited by the concentration and diffusion rates of gas molecules in water. In this case, macroporous water exhibited 6 times gas uptake compared to nonporous (pure) water. Furthermore, by leveraging the high gas capacity and enhanced diffusion kinetics, the limiting diffusion current of oxygen reduction reaction (ORR) in macroporous water is 2 times that in nonporous water, offering promising prospects for sustainable energy conversion technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electromagnetic Radioisotope Separator for Methods Development, Testing, and Training

The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.

07 ISOTOPE AND RADIATION SOURCES↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

Seshadria, Arunkumar↗

Modeled sensitivity of multi-MA accelerator performance to electrode contaminant inventory

Significant particle-in-cell code development has enabled simulations of power flow in multi-MA accelerators to include the desorption of surface contaminants, their ionization into surface plasmas, and the impact of these plasmas on efficiency. The simulations base desorption on an Arrhenius equation, whose most significant unknown is the surface contaminant inventory. The sensitivity of power-flow simulations to this inventory is studied here using Sandia National Laboratories' Z accelerator with a 7-nH MagLIF load [Phys. Plasmas 17, 056303 (2010)]. Simulations are conducted in 3D cylindrical coordinates for the current-adder, or “convolute,” region of Z and in 2D for the final feed only. Simulated contaminant inventories are varied from 1 to 32 monolayers (MLs) in 2D, and 2 to 4 ML in 3D. The results reveal sensitivities to the local ratio of E/B⁠. The high B-field, low E-field region near the short-circuit load is insensitive to the contaminant inventory, where assumed values of 4–32 ML change the load current by ≤ 2%, and agree with experiment to within 2% at peak current. A 1-ML value is the outlier, increasing the load current by 5%, but still within measurement uncertainty. In contrast, the relatively higher E-field, lower B-field convolute region has slower contaminant desorption and higher-magnitude E-field penetration of the surface plasmas. The current loss in the convolute region does increase with contaminant inventory. The loss assuming 4 ML is 12% larger than for 2 ML, with 4 ML being the better match to experiment.

Arrhenius equation↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

General kinetic ion-induced electron emission model for metallic walls applied to biased Z-pinch electrodes

A kinetic ion-induced electron emission (IIEE) model for general applications is developed to obtain the emitted electron energy spectrum for a distribution of ion impacts on a metallic surface. We assume an ionization cascade mechanism and use empirical models for the ion and electron stopping powers. The emission spectrum and the secondary electron yield (SEY) are validated for a variety of materials. The IIEE model is used to study the effect of IIEE on the plasma-material interactions of Z-pinch electrodes. Un-magnetized Boltzmann-Poisson simulations are performed for a Z-pinch plasma doubly bounded by two biased copper electrodes with and without IIEE at bias potentials from 0 to 9 kV. At the anode, the SEY decreases from 0 to 1 kV, but then increases at higher bias potentials. At the cathode, the SEY is much larger due to higher energy ion bombardment and grows with bias potential. As the bias potential increases, the emitted cathode electrons are accelerated to higher energies into the domain, collisionally heating the plasma. Above 1 kV, the heating is strong enough to increase the plasma potential. Despite SEY greater than 1, only a classical sheath forms as opposed to a space-charge limited or inverse sheath due to the emitted electron flux not reaching the space charge current saturation limits. Furthermore, the current in the emissionless cases saturates to a value lower than experiment. With IIEE, the current does not saturate and continues to increase with the 4 kV case, matching most closely with the experiment.

Carbon based materials↗

Fragmentation dynamics of CS 2 dications and trications following S 2p ionization

Here, we present the results from a detailed study of the fragmentation dynamics of CS$_2^{2+}$ and CS$_2^{3+}$, formed in intense femtosecond soft x-ray pulses above the sulfur 2p edge, primarily through single core photoionization from the S 2p site, and subsequent Auger–Meitner decay(s). By combining three-dimensional velocity map imaging with covariance analysis, we determine the relative momenta of the ions produced in each two- and three-body fragmentation channel, at significantly higher ion count rates than conventional coincidence measurements. We shed new light on the wide range of fragmentation channels observed from the CS 2 dication and trication, including channels that involve ionization-induced bond formation and fragmentations producing undetected neutral cofragments. In the latter case, a “native frames” approach is used to isolate contributions from concerted and sequential fragmentations and extract dynamical information about each step of a concerted fragmentation process. While dications often fragment sequentially, the trication is dominated by concerted fragmentation. The main trication fragmentation channel into S + + C + + S + can be well-approximated by classical Coulombic simulations of the ground-state geometry distribution, reflecting both the nature of the trication potential energy surface and the rapid multiple ionization prior to substantial structural dynamics. This study demonstrates ways in which fundamental insights into the fragmentation dynamics of polycations following x-ray ionization may be extracted, which will be beneficial to future studies that employ time-resolved x-ray Coulomb explosion imaging to study ultrafast photochemistry.

Allum, Felix [Deutsches Elektronen-Synchrotron (DE↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

An Exceptionally Powerful, Radiatively Driven Ultrafast Outflow in the Rapidly Accreting AGN RE J1034+396

We report the analysis of ∼1 Ms of XMM-Newton observations of the rapidly accreting active galactic nucleus RE J1034+396. The 0.3–9 keV EPIC-pn spectra are well described by a model consisting of steep continuum emission from the corona accompanied by relativistically blurred reflection from a highly ionized accretion disk. The source is known to exhibit strong excess soft X-ray emission, which we show is well represented by thermal disk photons Comptonized by a warm plasma spanning the inner accretion flow. Additionally, the EPIC-pn data provide compelling evidence (ΔC ∼ 60 for four additional parameters) for the presence of an ultrafast outflow (UFO) with a line-of-sight velocity v/c = 0.307$^{+0.001}_{-0.005}$, and an emission signature consistent with reflection of the corona from modestly ionized, outflowing gas. The simultaneous 0.5–2.5 keV RGS spectra show clear absorption lines. Modelling of these data confirms the presence of the UFO and constrains its equivalent hydrogen column density, log N H /(atom cm −2 ) = 21.7$^{+0.1}_{-0.2}$. The RGS data also reveal at least two warm absorber components with a modest outflow velocity (1680$^{+40}_{-50}$ km s -1 ). The measured properties and time evolution of the UFO in RE J1034+396 suggest that it is formed from collisionally ionized plasma, launched from the disk surface and accelerated by radiation pressure. The high terminal velocity and substantial absorbing column density imply that the outflow carries sufficient momentum and energy to transform its environment, being capable of driving out essentially all dust and gas it interacts with along the line of sight, even if the AGN were initially surrounded by a Compton-thick absorber.

79 ASTRONOMY AND ASTROPHYSICS↗

FIREFLY: heat load and particle exhaust approximations for rapid evaluation of divertor designs

The divertor in a magnetic confinement fusion reactor is an essential component for power dissipation and particle removal. The FIREFLY package for rapid evaluation of divertor designs is presented as an extension of the FLARE code for field line reconstruction from a flux tube mesh. First, divertor loads are approximated with a simplified heat transport model. Neutralized particles are then sampled from the resulting load distribution, and the EIRENE code is used to track molecules and atoms in a plasma background while accounting for dissociation, charge exchange and ionization. Particles are removed on pumping surfaces in order to estimate the exhaust efficiency for a given divertor geometry. Optimization of the divertor geometry for more efficient particle exhaust is explored by using W7-X as an example, and the sensitivity to model parameters for the plasma background in the proxy calculations is evaluated.

mesh generation, magnetic field lines, scrape-off ↗

Determining star formation rates in AGN hosts from strong optical emission lines

ABSTRACT The influence of Active Galactic Nuclei (AGN) on star formation within their host galaxies remains a topic of intense debate. One of the primary challenges in quantifying the star formation rate (SFR) within AGN hosts arises from the prevalent assumption in most methodologies, which attribute gas excitation to young stars alone. However, this assumption does not consider the contribution of the AGN to the ionization of the gas in their environment. To address this issue, we evaluate the use of strong optical emission lines to obtain the SFR surface density ($\Sigma {{\rm SFR_{AGN}}}$) in regions predominantly ionized by an AGN, using a sample of 293 AGN hosts from the MaNGA survey, with SFR measurements available through stellar population fitting. We propose calibrations involving the H$\alpha$ and [O iii]$\lambda$5007 emission lines, which can be used to determine $\Sigma {{\rm SFR_{AGN}}}$, resulting in values consistent with those estimated through stellar population fitting.

de Mellos, Maitê S. Z. (ORCID:0009000821841403)↗