Search NASA⌕ Search

SEARCH · Search NASA

Results for “SWITCHING CIRCUIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low cost switching circuit for van der Pauw resistivity and Hall measurements at various temperatures

The electrical characterization of materials, particularly superconductors, semiconductors, and those undergoing metal-insulator transitions (MITs), relies significantly on resistivity and Hall measurements as a function of temperature. The van der Pauw four-point probe method is commonly used for such measurements, which involves resistance measurements for different circuit configurations connected to sample contacts. However, repeating these measurements at different temperatures is challenging and time consuming. Here, this study introduces a novel approach utilizing a switching circuit controlled by an Arduino device and a LabVIEW program to automate resistance measurements for different electrical configurations. The effectiveness of this setup was demonstrated by testing V 2 O 3 thin film samples deposited on Al 2 O 3 (001) substrates using DC magnetron sputtering. The MIT temperature of the sample was 115 K during heating and 100 K during cooling. The sample exhibited p-type charge carriers with a Hall coefficient of 1.3 ± 0.1 x 10 -4 cm 3 /C and Hall mobility of 1.7 x 10 -1 cm 2 /V∙s, which is consistent with findings from other studies employing commercial equipment.

36 MATERIALS SCIENCE↗

Wide bandgap optical switch circuit breaker

A high-voltage switch is adapted for use as a medium-voltage direct current circuit breaker, which provides a low-cost, small-footprint device to mitigate system faults. In one example, a method for operating a wideband optical device includes illuminating the wide bandgap optical device with a light within a first range of wavelengths and a first average intensity, allowing a current to propagate therethrough without substantial absorption of the current, illuminating the wide bandgap optical device with light within the first range of wavelengths and a second average intensity that is lower than the first average intensity to allow a sustained current flow though the wide bandgap optical device, and illuminating the wide bandgap optical device with light within a second range of wavelengths to stop or substantially restrict propagation of the current through the wide gap material.

Voss, Lars F.↗

Wide bandgap optical switch circuit breaker for controlling propagation of current therethrough a wide bandgap optical device

A high-voltage switch is adapted for use as a medium-voltage direct current circuit breaker, which provides a low-cost, small-footprint device to mitigate system faults. In one example, a method for operating a wideband optical device includes illuminating the wide bandgap optical device with a light within a first range of wavelengths and a first average intensity, allowing a current to propagate therethrough without substantial absorption of the current, illuminating the wide bandgap optical device with light within the first range of wavelengths and a second average intensity that is lower than the first average intensity to allow a sustained current flow though the wide bandgap optical device, and illuminating the wide bandgap optical device with light within a second range of wavelengths to stop or substantially restrict propagation of the current through the wide gap material.

Voss, Lars F.↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ripple canceling in power conversions circuits

A power circuit substantially canceling ripples at the source. The power circuit includes a switching circuit configured to control a power flow between an input and an output, a main storage element electrically connected in series with the switching circuit, and a resonant tank electrically coupled to the switching circuit and configured to compensate for switching ripples in the main storage element. Aspects of the invention can be applied to a converter circuit or to an inverter circuit.

Shamsi, Pourya↗

Systems and methods of delivering rectified voltage to a load

A solid state light source driver circuit that operates in either a buck convertor or a boost convertor configuration is provided. The driver circuit includes a controller, a boost switch circuit and a buck switch circuit, each coupled to the controller, and a feedback circuit, coupled to the light source. The feedback circuit provides feedback to the controller, representing a DC output of the driver circuit. The controller controls the boost switch circuit and the buck switch circuit in response to the feedback signal, to regulate current to the light source. The controller places the driver circuit in its boost converter configuration when the DC output is less than a rectified AC voltage coupled to the driver circuit at an input node. The controller places the driver circuit in its buck converter configuration when the DC output is greater than the rectified AC voltage at the input node.

Palmer, Fred↗

A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch

Fast optical circuit switching has great potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. In this work we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Surge-Energy and Overvoltage Ruggedness of P-Gate GaN HEMTs

An essential ruggedness of power devices is the capability of safely withstanding the surge energy. The surge ruggedness of the GaN high-electron-mobility transistor (HEMT), a power transistor with no or minimal avalanche capability, has not been fully understood. This article unveils the comprehensive physics associated with the surge-energy withstand process and the failure mechanisms of p-gate GaN HEMTs. Two commercial p-gate GaN HEMTs with Ohmic- and Schottky-type gate contacts are studied. Two circuits are developed to study the device surge ruggedness: an unclamped inductive switching circuit is first used to identify the withstand dynamics and failure mechanisms, and a clamped inductive switching circuit with a controllable parasitic inductance is then designed to mimic the surge energy in converter-like switching events. The p-gate GaN HEMT is found to withstand the surge energy through a resonant energy transfer between the device capacitance and the load/parasitic inductance rather than a resistive energy dissipation as occurred in the avalanche. If the device resonant voltage goes below zero, the device reversely turns on and the inductor is discharged. The device failure occurs at the transient of peak resonant voltage and is limited by the device overvoltage capability rather than the surge energy, dV/dt , or overvoltage duration. Almost no energy is dissipated in the resonant withstand process and the device failure is dominated by an electric field rather than a thermal runaway. Furthermore, these results provide critical understandings on the ruggedness of GaN HEMTs and important references for their qualifications and applications.

42 ENGINEERING↗

Optics Enabled Networks and Architectures for Data Center Cost and Power Efficiency

Bandwidth demand for datacenter networks continues as performance increases and is further fueled by the exploding demand for AI and new HPC workloads. Managing power and costs will require a range of solutions including new networking and workload specialized architectures, composable systems and optical circuit switching. In this study we focus primarily on two topics, examining the benefits of flatter networks (enabled mainly by means of co-packaged-optics-enabled switches) and the utilization improvement potential for composable (disaggregated) systems, while discussing specialized hardware and networks, and optical circuit switching more briefly.

99 GENERAL AND MISCELLANEOUS↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

Performance trade-offs in reconfigurable networks for HPC

Designing efficient interconnects to support high-bandwidth and low-latency communication is critical toward realizing high performance computing (HPC) and data center (DC) systems in the exascale era. At extreme computing scales, providing the requisite bandwidth through overprovisioning becomes impractical. These challenges have motivated studies exploring reconfigurable network architectures that can adapt to traffic patterns at runtime using optical circuit switching. Despite the plethora of proposed architectures, surprisingly little is known about the relative performances and trade-offs among different reconfigurable network designs. We aim to bridge this gap by tackling two key issues in reconfigurable network design. First, we study how cost, power consumption, network performance, and scalability vary based on optical circuit switch (OCS) placement in the physical topology. Specifically, we consider two classes of reconfigurable architectures: one that places OCSs between top-of-rack (ToR) switches—ToR-reconfigurable networks (TRNs)—and one that places OCSs between pods of racks—pod-reconfigurable networks (PRNs). Second, we tackle the effects of reconfiguration frequency on network performance. Our results, based on network simulations driven by real HPC and DC workloads, show that while TRNs are optimized for low fan-out communication patterns, they are less suited for carrying high fan-out workloads. PRNs exhibit better overall trade-off, capable of performing comparably to a fully non-blocking fat tree for low fan-out workloads, and significantly outperform TRNs for high fan-out communication patterns.

Teh, Min Yee↗

Current source inverter with bi-directional switches

A switching circuit includes a diode, a semiconductor switch, and a first bidirectional switch. The semiconductor switch is configured to conduct a first current from a second terminal to a third terminal of the semiconductor switch when a first on-state signal is sent to a first terminal of the semiconductor switch. An anode of the diode is connected to the second terminal of the semiconductor switch, and a cathode of the diode is connected to the third terminal of the semiconductor switch. The first bidirectional switch includes a first terminal, a second terminal connected to the anode of the diode, and a third terminal and is configured to conduct a second current from the second terminal to the third terminal or from the third terminal to the second terminal when a second on-state signal is sent to the first terminal of the first bidirectional switch.

Dai, Hang↗

Plant-Enhanced Degradation Of Munitions by Engineered TERrestrial microbes (PEDOMETER) (Final Report)

LLNL led two major Technical Areas (TAs) within the PEDOMETER program: TA3 focused on biocontainment and TA4 focused on developing electrochemical TNT degradation sensors and testbeds. A key takeaway from our work is the importance of chassis host strain choice for kill switch design and actuator choice. Genetic instability of the kill switch circuit is a major barrier toward establishing a kill switch, which is host dependent. Addition of a host down-selection step to regulator and actuator screening stages would be beneficial to hasten kill switch development.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid power circuit having switch-mode power transformer and methods

A fluid power circuit with a switch-mode power transformer used to transfer power while keeping the pressure of power source and reverse osmosis processes relatively decoupled. The switch-mode power transformer uses the inertia of a hydraulic motor driven electric generator and switching of a hydraulic motor inlet between high and low-pressure ends to decrease the pressure at which power is being transmitted to a reverse osmosis process.

Simmons, II, Jeremy W.↗

Prolonging genetic circuit stability through adaptive evolution of overlapping genes

Abstract The development of synthetic biological circuits that maintain functionality over application-relevant time scales remains a significant challenge. Here, we employed synthetic overlapping sequences in which one gene is encoded or ‘entangled’ entirely within an alternative reading frame of another gene. In this design, the toxin-encoding relE was entangled within ilvA, which encodes threonine deaminase, an enzyme essential for isoleucine biosynthesis. A functional entanglement construct was obtained upon modification of the ribosome-binding site of the internal relE gene. Using this optimized design, we found that the selection pressure to maintain functional IlvA stabilized the production of burdensome RelE for >130 generations, which compares favorably with the most stable kill-switch circuits developed to date. This stabilizing effect was achieved through a complete alteration of the allowable landscape of mutations such that mutations inactivating the entangled genes were disfavored. Instead, the majority of lineages accumulated mutations within the regulatory region of ilvA. By reducing baseline relE expression, these more ‘benign’ mutations lowered circuit burden, which suppressed the accumulation of relE-inactivating mutations, thereby prolonging kill-switch function. Overall, this work demonstrates the utility of sequence entanglement paired with an adaptive laboratory evolution campaign to increase the evolutionary stability of burdensome synthetic circuits.

59 BASIC BIOLOGICAL SCIENCES↗

Phasor-Based Control for Scalable Solar PV Integration

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

14 SOLAR ENERGY↗