Search NASA⌕ Search

SEARCH · Search NASA

Results for “Safety Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Differentiable Predictive Control with Safety Guarantees: A Control Barrier Function Approach

In this paper, we develop a novel form of differentiable predictive control (DPC) with safety and robustness guarantees. DPC is a form of approximate model predictive control (MPC), wherein the control policy is a neural network that learns a receding horizon, optimal control law. The proposed approach exploits a new form of sampled-data barrier function to enforce safety, while only interrupting the neural network-based controller near the boundary of the safe set. The effectiveness of the proposed approach is demonstrated in simulation.

Shaw Cortez, Wenceslao E.↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Nonlinear control of safety factor gradient in tokamaks using spatially variable electron cyclotron current drives

Active control of plasma properties may be necessary to achieve stable operation of next-generation tokamaks over large time scales. Such control algorithms can regulate the plasma properties to avoid the onset of magnetohydrodynamic (MHD) instabilities. For instance, the global and local properties of the safety factor profile are linked to the onset of neoclassical tearing modes (NTMs). This work proposes a model-based control approach for deterring/delaying NTMs through active modulation of one of the safety factor properties - the gradient of the safety factor profile at a particular rational safety factor surface. In particular, a novel control-oriented model for the local safety factor gradient is developed. The nonlinear control model is governed by a nonautonomous ordinary differential equation that accounts for a given rational safety factor surface’s spatial variation over time. Further, to improve the controllability of the spatially evolving parameter, the control model treats ECH&CD positions, along with noninductive powers, as controllable variables. A nonlinear control algorithm based on feedback linearization with optimization is synthesized to achieve the objective of regulating the safety factor gradient around a given target. The proposed algorithm allocates optimal ECH&CD positions, in addition to auxiliary powers, at each time instant as the rational safety factor surface drifts to locations with a low control authority. Stability guarantees of the proposed control law are also discussed in this work. The proposed algorithm is tested for a DIII-D tokamak scenario in nonlinear simulations carried out using the Control Oriented Transport SIMulator (COTSIM). Both fixed and moving ECH&CD cases are studied, and their outcomes are compared. Simulation results demonstrate that enthusiastic regulation of the safety factor gradient can be achieved during the ramp-up and flat-top phases of tokamak operation in both fixed and moving ECH&CD cases. However, real-time updates of ECH&CD positions can prevent the saturation of auxiliary powers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN

The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coordinated frequency regulation among asynchronous AC grids with an MTDC system

With the increasing penetration level of renewable power, the power systems’ inertias are decreasing. To ensure that the frequency is above the threshold of the under frequency load shedding, one effective way is to share the spinning reserves among asynchronous AC grids through HVDC systems. In this paper, a coordinated frequency regulation scheme that enables spinning reserves sharing is proposed for such hybrid AC/DC grids. This scheme is a communication-free method that consists of the droop control, the inertia emulation control and the frequency safety control. The combined response of the three controls can increase not only the frequency nadir but also the settled frequency of the disturbed grid. In addition, the hysteresis comparators and the power injection limits are adopted in the frequency regulation scheme to reduce the coupling effect among AC grids. Thus, under small and harmless disturbance, the frequency regulation scheme will be inactive; the disturbance in strong AC grids would not affect the weak AC systems. The frequency regulation scheme coordinates well with the automatic generation control of the grids. Furthermore, the feasibility and effectiveness of the proposed frequency regulation scheme are verified through simulation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SNS Credited Beam Power Limit System Preliminary Design

The Controls Group at the Spallation Neutron Source (SNS) is designing a programmable signal processor based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge. The system must reliably shut off the beam if the average power exceeds 2.145 MW averaged over 60 seconds. This paper discusses architecture and design choices needed to develop the system under the auspices of a programmable radiation-safety credit control.

Deibele, Craig↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

2020 Transportation Research Board Workshop: Infrastructure Spatial Sensing at Intersections: The Potential to Enhance Safety and Enable Automation

The sensing technology that is enabling vehicle automation also can revolutionize traffic intersection safety, control, and efficiency. Infrastructure spatial sensing technology refers to the deployment of sensors that can detect and track all objects in the field of view - for example, mounting lidar sensors, radar, and video imaging at an intersection and fusing the data to produce a three-dimensional dynamic operational awareness. Combining such sensing capability with fail-safe vehicle communications can facilitate applications such as eco-approach and departure, optimizing efficient vehicle-signal coordination, and reducing traffic accidents through increasing safety. Furthermore, evidence is mounting suggesting that infrastructure-based sensing is needed in order to safely deploy automated public mobility alongside the normal vehicle and pedestrian traffic in our cities. Six speakers were invited to present their work from various aspects (safety, efficiency, and automation) addressing infrastructure-based sensing at the workshop on Infrastructure Spatial Sensing hosted in Washington DC as part of the Transportation Research Board Annual Meeting in January 12, 2019. A summary of the presentation are included herein.

47 OTHER INSTRUMENTATION↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concept of Operations of Next-Generation Traffic Control Utilizing Infrastructure-Based Cooperative Perception: Preprint

This paper puts forth a system architecture for an infrastructure-based cooperative perception (CP) fusion engine, to provide a complete state-space digital representation, with measurable accuracy, to support a wide-range of applications. The architecture includes the inputs, functional flow, data standardization recommendations, outputs and supported applications. The CP engine addresses critical needs with respect to accelerating the benefits of automation through intelligent roadway infrastructure (IRI), that complements and accelerates connected and automated vehicle (CAV) technology. that the CP acquires and fuses information from sensors (radar, LiDAR, and cameras), and CAVs to intelligently perceive roadway traffic states of all moving objects, create a complete three-dimensional digital representation of that state-space, and communicate it to downstream application such as intelligent signal control, safety and energy applications, and cooperate driving applications for CAVs as examples. The IRI approach, as opposed to a vehicle centric approach, is found to be more scalable in that it can deployed to the roughly 300,000 signalized intersections more readily than the over 300 million vehicles in the US, and accrues early-stage benefits equitable to all roadway users addressing safety, equity, fuel efficiency, and GHG reduction.

ADVANCED PROPULSION SYSTEMS↗

Concept of Operations of Next-Generation Traffic Control Utilizing Infrastructure-Based Cooperative Perception

This paper provides a system architecture for an infrastructure-based cooperative perception fusion engine for next-generation traffic control. This engine will provide a complete state-space digital representation with measurable accuracy to support a wide-range of applications. The architecture includes inputs, functional flow, data standardization recommendations, outputs, and supported applications. The cooperative perception engine addresses critical needs with respect to accelerating the benefits of automation through intelligent roadway infrastructure, which complements and accelerates connected and automated vehicle (CAV) technology. The cooperative perception acquires and fuses information from sensors (radar, LiDAR, and cameras) and CAVs to perceive roadway traffic states of moving objects, creates a complete 3D digital representation of that state-space, and communicates it to downstream application such as intelligent signal control, safety and energy applications, and cooperate driving applications. The intelligent roadway infrastructure approach, as opposed to a vehicle-centric approach, is more scalable because it can be deployed to the roughly 300,000 signalized intersections more readily than over 300 million vehicles in the United States, and accrues early-stage benefits equitable to all roadway users addressing safety, equity, fuel efficiency, and greenhouse gas reduction.

ADVANCED PROPULSION SYSTEMS↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗

Grid-scale Energy Storage Hazard Analysis & Design Objectives for System Safety

Battery based energy storage systems are becoming a critical part of a modernized, resilient power system. However, batteries have a unique combination of hazards that can make design and engineering of battery systems difficult. This report presents a systematic hazard analysis of a hypothetical, grid scale lithium-ion battery powerplant to produce sociotechnical "design objectives" for system safety. We applied system's theoretic process analysis (STPA) for the hazard analysis which is broken into four steps: purpose definition, modeling the safety control structure, identifying unsafe control actions, and identifying loss scenarios. The purpose of the analysis was defined as to prevent event outcomes that can result in loss of battery assets due to fires and explosions, loss of health or life due to battery fires and explosions, and loss of energy storage services due to non- operational battery assets. The STPA analysis resulted in identification of six loss scenarios, and their constituent unsafe control actions, which were used to define a series of design objectives that can be applied to reduce the likelihood and severity of thermal events in battery systems. These design objectives, in all or any subset, can be utilized by utilities and other industry stakeholders as "design requirements" in their storage request for proposals (RFPs) and for evaluation of proposals. Further, these design objectives can help to protect firefighters and bring a system back to full functionality after a thermal event. We also comment on the hazards of flow battery technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers - Phase 3

Several Department of Energy (DOE) facilities have materials stored in robust, welded, stainless - steel containers with presumed fire - induced pressure response behaviors. Lack of test data related to fire exposure requires conservative safety analysis assumptions for container response at these facilities. This conservatism can in turn result in the implementation of challenging operational restrictions with costly nuclear safety controls. To help address this issue for sites that store DOE 3013 stainless - steel containers, a series of ten tests were undertaken at Sandia National Laboratories. The goal of this test series was to obtain the response behavior for various configurations of DOE 3013 containers with various payload compositions when exposed to one of two ASTM fire conditions. Key parameters measured in the test series included identification of failure - specific characteristics such as pressure, temperature, and whether or not a vessel was breached during a test . Numerous failure - specific characteristics were identified from the ten tests. This report describes the implementation and execution of the test series performed to identify these failure - specific characteristics. Discussions on the test configurations, payload compositions, thermal insults, and experimental setups are presented. Test results in terms of pressurization and vessel breach (or no - breach) are presented along with corresponding discussions for each test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ray-Tracing Simulations Characterising the Performance of the Proposed 2024 HFIR HB4 Main Shutter

The Main Shutter at HB4 will serve two purposes after the HFIR Beryllium Reflector Replacement planned to take place in 2024. First as the primary certified safety control controlling the passage of neutrons from the cold source in the HFIR pressure vessel into the cold guide hall, and second as the first set of reflecting surfaces used to guide neutrons from the source and into the individual guide starts for each instrument in the cold guide hall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗