Effects of Sample Geometry and Loading Rate onTensile Ductility of TRIP800 Steel

The effects of sample geometry and loading rate on the tensile ductility of a commercial grade Transformation Induced Plasticity (TRIP) steel are examined in this paper. Quasistatic tensile tests were performed for the 1.2mm gauge TRIP800 steel sheets with two geometries: sub-sized ASTM E-8 and a custom designed miniature tensile sample. Sample geometry effects on post-uniform elongation are discussed together with other experimental data reported in the open literature. Further discussions on the effects of sample geometry are cast in the context of mesh-size dependent ductility in finite element-based engineering simulations. The quasi-static tensile curve for the miniature sample is then compared with the split Hopkinson bar results at the loading rates of 1700-S-1 and 2650-S-1 with the same sample design. In contrary to the typical strain rate sensitivity results for mild steel where the dynamic strength increase at high strain rate usually occurs at the price of ductility reduction, our results show that the TRIP800 under examination has positive strain rate sensitivity on both strength and ductility. Images of the deformation process captured by high speed camera together with scanning electron microscopy (SEM) near the fracture zone are also used to elucidate the different deformation modes at different loading rates.

36 MATERIALS SCIENCE↗

Effect of sample geometry on the phase boundary of a mesoscopic superconducting loop.

We studied the effect of sample geometry on the evolution of the superconducting state in nanoscale Nb circular and square loops by transport measurements. A multistage resistive transition with temperature is found for both samples, which is related to the effect of contact leads made from the same superconducting material. The H-T phase diagrams close to T{sub c0} show clear periodic oscillations on top of a parabolic background, i.e., Little-Parks effect. However, the amplitude of the oscillations decreases faster in the circular loop compared to the one in the square sample. Numerical simulations are conducted within the nonlinear Ginzburg-Landau theory to show the effect of sample geometry on the nucleation of superconductivity in superconducting loop structures.

36 MATERIALS SCIENCE↗

Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV

Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of {epsilon} = A{Epsilon}{sup a}+B{Epsilon}{sup b}, where {epsilon} is efficiency, {Epsilon} is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a ''knee'' at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of temperature, humidity, sample geometry, and other variables on Bruceton type 12 impact initiation of HMX-based high explosives

The drop weight impact test, developed at Bruceton Naval Research Laboratory 60 years ago, is still the most commonly used configuration for evaluating sensitivity of explosives to non-shock ignition. The standard drop weight impact test is performed under ambient conditions for temperature and humidity - variations in which are known to significantly affect the probability of reaction. We have performed a series of impact tests in an attempt to characterize the effect of temperature, humidity, sample geometry (height, mass, L/d, and pressed density), sample confinement, and impact surface properties (strength and coefficient of friction) on the probability of reaction in a drop weight impact test. Differences in the probability of reaction have been determined across a range of drop heights for each configuration. The results clearly show significant shifts in the probability of reaction and in the slope of the reaction probability curve for several of the variables.

66↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the Effect of Sample Geometry on Temperature Distribution during Optical Floating Zone Crystal Growth in Vacuum Environment through Heat Transfer Modeling

Optical floating zone furnaces (OFZ) have had a transformative impact on fundamental science due to their ability to rapidly produce large single crystals of a wide variety of complex materials. However, a quantitative understanding of the OFZ growth environment is generally lacking due to the difficulty of measuring the local sample temperatures during OFZ growth, as well as to the general lack of information about the temperature-dependent physical parameters needed to model heat transfer. To overcome these challenges, we apply a physics-based heat transfer model, parametrized by measurements from synchrotron experiments and a machine-learning (ML) algorithm, to simulate the temperature distributions of samples heated in an OFZ furnace in a vacuum environment. This model is used to quantitatively understand how the sample maximum temperature and temperature gradient (key parameters that influence the success of crystal growth) are affected by the rod size, rod shape, and heat-zone position on the rod. The results of this study can be applied to make informed decisions on how crystal growth parameters can be tuned to modify temperature profiles and to optimize crystal growth outcomes even when data on internal sample temperature profiles (e.g., those obtained through in situ synchrotron experiments) are not accessible.

36 MATERIALS SCIENCE↗

Microfabrication of controlled-geometry samples for the laser-heated diamond-anvil cell using focused ion beam technology

The pioneering of x-ray diffraction with in situ laser heating in the diamond-anvil cell has revolutionized the field of high-pressure mineral physics, expanding the ability to determine high-pressure, high-temperature phase boundaries and equations of state. Accurate determination of high-pressure, high-temperature phases and densities in the diamond-anvil cell rely upon collinearity of the x-ray beam with the center of the laser-heated spot. We present the development of microfabricated samples that, by nature of their design, will have the sample of interest in the hottest portion of the sample. We report initial successes with a simplified design using a Pt sample with dimensions smaller than the synchrotron-based x-ray spot such that it is the only part of the sample that absorbs the heating laser ensuring that the x-rayed volume is at the peak hotspot temperature. Microfabricated samples, synthesized using methods developed at The Ohio State University's Mineral Physics Laboratory and Campus Electron Optics Facility, were tested at high P-T conditions in the laser-heated diamond-anvil cell at beamline 16 ID-B of the Advanced Photon Source. Pt layer thicknesses of {le} 0.8 {micro}m absorb the laser and produce accurate measurements on the relative equations of state of Pt and PtC. These methods combined with high-purity nanofabrication techniques will allow for extension by the diamond-anvil cell community to multiple materials for high-precision high-pressure, high-temperature phase relations, equations of state, melting curves, and transport properties.

43 PARTICLE ACCELERATORS↗

Development of test methodology for dynamic mechanical analysis instrumentation

Dynamic mechanical analysis instrumentation was used for the development of specific test methodology in the determination of engineering parameters of selected materials, esp. plastics and elastomers, over a broad range of temperature with selected environment. The methodology for routine procedures was established with specific attention given to sample geometry, sample size, and mounting techniques. The basic software of the duPont 1090 thermal analyzer was used for data reduction which simplify the theoretical interpretation. Clamps were developed which allowed 'relative' damping during the cure cycle to be measured for the fiber-glass supported resin. The correlation of fracture energy 'toughness' (or impact strength) with the low temperature (glassy) relaxation responses for a 'rubber-modified' epoxy system was negative in result because the low-temperature dispersion mode (-80 C) of the modifier coincided with that of the epoxy matrix, making quantitative comparison unrealistic.

Allen, V. R.↗

Monte Carlo simulation study of scanning Auger electron images

Simulation of contrast formation in Auger electron imaging of surfaces is helpful for analyzing scanning Auger microscopy/microanalysis (SAM) images. In this work, we have extended our previous Monte Carlo model and the simulation method for calculation of scanning electron microscopy (SEM) images to SAM images of complex structures. The essentials of the simulation method are as follows. (1) We use a constructive solid geometry modeling for a sample geometry, which is complex in elemental distribution, as well as in topographical configuration and a ray-tracing technique in the calculation procedure of electron flight steps that across the different element zones. The combination of the basic objects filled with elements, alloys, or compounds enables the simulation to a variety of sample geometries. (2) Sampled Auger signal electrons with a characteristic energy are generated in the simulation following an inner-shell ionization event, whose description is based on the Castani's inner-shell ionization cross section. This paper discusses in detail the features of simulated SAM images and of line scans for structured samples, i.e., the objects embedded in a matrix, under various experimental conditions (object size, location depth, beam energy, and the incident angle). Several effects are predicted and explained, such as the contrast reversion for nanoparticles in sizes of 10-60 nm, the contrast enhancement for particles made of different elements and wholly embedded in a matrix, and the artifact contrast due to nearby objects containing different elements. The simulated SAM images are also compared with the simulated SEM images of secondary electrons and of backscattered electrons. The results indicate that the Monte Carlo simulation can play an important role in quantitative SAM mapping.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Anisotropy in thermal conductivity of graphite flakes–SiC{sub p}/matrix composites: Implications in heat sinking design for thermal management applications

Within the frame of heat dissipation for electronics, a very interesting family of anisotropic composite materials, fabricated by liquid infiltration of a matrix into preforms of oriented graphite flakes and SiC particles, has been recently proposed. Aiming to investigate the implications of the inherent anisotropy of these composites on their thermal conductivity, and hence on their potential applications, materials with matrices of Al–12 wt.% Si alloy and epoxy polymer have been fabricated. Samples have been cut at a variable angle with respect to the flakes plane and thermal conductivity has been measured by means of two standard techniques, namely, steady state technique and laser flash method. Experimental results are presented and discussed in terms of current models, from which important technological implications for heat sinking design can be derived. - Highlights: • Anisotropy in thermal conductivity of graphite flakes-based composites is evaluated. • Samples are cut in a direction forming a variable angle with the oriented flakes. • For angles 0° and 90°, thermal conductivity does not depend on sample geometry. • For intermediate angles, thermal conductivity strongly depends on sample geometry. • “Thin” samples must be thicker than 600 μm, “thick” samples must be encapsulated.

36 MATERIALS SCIENCE↗

Multivariate Calibration Models for Sorghum Composition using Near-Infrared Spectroscopy

NREL developed calibration models based on near-infrared (NIR) spectroscopy coupled with multivariate statistics to predict compositional properties relevant to cellulosic biofuels production for a variety of sorghum cultivars. A robust calibration population was developed in an iterative fashion. The quality of models developed using the same sample geometry on two different types of NIR spectrometers and two different sample geometries on the same spectrometer did not vary greatly.

09 BIOMASS FUELS↗

Low Temperature Time-to-Explosion Experiments on HMX in the LLNL's ODTX/P-ODTX System (FY 2020 Annual Report)

Over the last few decades, there has been a considerable research effort on the thermal decomposition and thermal explosion violence of energetic materials at elevated temperatures in different sample geometries and confinements. Thermal explosion studies on various energetic materials in two-dimensional geometry such as the Scaled-Thermal-Explosion-Experiment (STEX) system and the Sandia-Instrumented-Thermal-Ignition (SITI) system have been reported. The One-Dimensional Time to Explosion (ODTX) system, designed and built by LLNL, has been used since 1970s for thermal explosion studies. The system is attractive because of the one-dimensional geometry and minimal sample requirement. With the recent integration of a pressure monitoring element, the system can study pressure behavior of materials subjected to and during thermal exposure. Rapid pressure monitoring in µsec intervals allow for enhanced pressure determination in the time right before thermal explosion. The test data can be used for the validation of existing thermal models, particularly for introducing pressure terms. This report summarizes the efforts in performing small-scale safety tests, particle size measurements and conducting 7 ODTX/P-ODTX experiments on the Cl5 HMX material that Hunting uses for oil field applications.

36 MATERIALS SCIENCE↗

Innovative Nuclear Materials Outboard-A Project Specimen Preparation Guide

The Innovative Nuclear Materials (INM) Program was recently established by the U.S. Department of Energy (DOE) to develop advanced material technologies for use in nuclear reactors. The INM program is presently focused on researching in-core non-fueled materials for application in fast spectrum nuclear reactors. The widespread deployment of fast reactors continues to be a prominent aspiration for advanced nuclear technology developers. However, companies working to license these reactors have no choice but to rely on historic material technologies since further optimization and advancement of these materials is impeded by the lack of fast neutron irradiation test facilities. INM-OA is a non-fueled drop-in experiment which will irradiate material specimens of interest to fast reactor applications. This experiment will be irradiated at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR) outboard-A (OA) position during normal and high temperature steady state (HTSS) cycles. It will include material specimens supplied by members of the INM program and will utilize a cadmium-lined basket to filter out incident thermal neutrons, thus simulating a faster neutron energy spectrum. Material specimens will undergo post-irradiation examination including microscopy and mechanical testing. In addition to absorption reactions, fast neutrons cause microstructural damage in materials by atom displacement, which can cause exacerbated changes in physical properties and behavior. Thus, the data obtained from the INM-OA experiment will be crucial for understanding the engineering-scale behavior of reactor materials. This document is intended for the Principal Investigators providing samples for this project. Topics included are a general description of the experiment, the irradiation experiment/capsule design, sample geometries, number of samples to be provided, documentation to be provided, a brief list potentially useful characterization methods that can be leveraged at INL, and other miscellaneous requirements specific to this project. This document is intended for informational use only.

innovative nuclear materials↗

Impact of parasitic thermal effects on thermoelectric property measurements by Harman method

Harman method is a rapid and simple technique to measure thermoelectric properties. However, its validity has been often questioned due to the over-simplified assumptions that this method relies on. Here, we quantitatively investigate the influence of the previously ignored parasitic thermal effects on the Harman method and develop a method to determine an intrinsic ZT. We expand the original Harman relation with three extra terms: heat losses via both the lead wires and radiation, and Joule heating within the sample. Based on the expanded Harman relation, we use differential measurement of the sample geometry to measure the intrinsic ZT. To separately evaluate the parasitic terms, the measured ZTs with systematically varied sample geometries and the lead wire types are fitted to the expanded relation. A huge discrepancy (∼28%) of the measured ZTs depending on the measurement configuration is observed. We are able to separately evaluate those parasitic terms. This work will help to evaluate the intrinsic thermoelectric property with Harman method by eliminating ambiguities coming from extrinsic effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Landsat D Thematic Mapper image resampling for scan geometry correction

The Landsat D system is described, and the geometric correction processing for the Thematic Mapper (TM) is reviewed. The resampling procedure (the generation of a TM output image) is analyzed with emphasis on the effect of sampling geometry on output image. Effects of scan gaps and spacecraft jitter on output image are studied by means of a simulation of the sampling and resampling processes for three sampling geometries. Visual inspection of the resampling results shows that the resampling algorithm works excellently under all conditions and that distortion is visible only in the rare case of large gaps between scans.

Prakash, A.↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.