Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sand heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heating effects on jack pine pyrogenic organic matter properties from a pyrocosm study in 2022

This dataset contains data associated with the preprint “Fire removes preexisting pyrogenic organic matter from the ecosystem through the mechanisms of both direct combustion and increasing mineralizability” (Luo et al., 2025b), which is the complementary study to the published paper “Reburning pyrogenic organic matter: a laboratory method for dosing dynamic heat fluxes from above” (Luo et al., 2025a). We designed a full-factorial experiment with different burial depths of jack pine (Pinus banksiana Lamb) pyrogenic organic matter (PyOM) (Surface, 1 cm, and 5 cm) and different heat-flux profiles (High, Low, and Control) to examine how subsequent fires affect the properties of preexisting PyOM. We measured total carbon (C), pH, dissolved organic carbon (DOC), dissolved inorganic carbon (DIC), and mineralized C (as CO₂-C, from a 12-week incubation).We found that high heat flux and/or surface placement resulted in substantial direct C losses through combustion. Intermediate heat exposure produced both combustion losses and increases in DOC and mineralizability, which may have complex long-term implications: an increased dissolved fraction of PyOM may promote downward transport into mineral soils and potentially contribute to deeper, longer-term C storage, but it may also make PyOM more susceptible to microbial decomposition. Under the lowest heat flux and deepest burial, most PyOM was retained, and changes in DOC and C mineralization were minimal. Finally, PyOM pH, an important chemical property, decreased under low-temperature heating but increased under higher temperatures.We uploaded pH data for all samples (“pH_of_all_samples.csv”); pH and temperature-related data (peak temperature and degree hours) for samples in High and Low heat-flux treatments (“pH_vs_peakT_and_degree_hours_only_for_heated_samples.csv”); total C data (“CN_pct_C_stock_C_loss_in_samples.csv”); DOC and DIC data (“doc_dic.csv”); and mineralized C (CO₂-C) data (“CO2-C_all_original.csv”). Additional details can be found in the Methods & Sampling section.All datasets uploaded to ESS-DIVE are clearly labeled, cleaned, and include both raw and derived data, ready for reuse in other analyses. All analysis code and raw datasets are also available on GitHub: https://github.com/MengmengLuo/Fire-removes-preexisting-pyrogenic-organic-matter-from-the-ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Sand-Based Thermal Storage for Building Heating Applications: A District Energy Case Study

Buildings account for 40% of global energy consumption and contribute to 30% of global carbon emissions. As energy from renewable sources increases in availability and building designers push for increased electrification, thermal energy storage (TES) systems will play a crucial role in extending the usable time horizon of renewable energy. While water, molten salt, and phase change materials are typically used for building TES heating applications, silica-sand has emerged as an alternative medium for concentrated solar power applications due to its low cost, wide availability, and comparable system efficiency. This paper proposes a new silica-sand particle-based TES system for building heating applications. In this work, a novel steam plant for district heating applications is first designed to utilize silica-sand TES, which can be used for different district energy systems. To demonstrate the silica-sand TES plant performance, the design is modelled in Modelica based on a case study on the University of Colorado Boulder’s campus. The simulation results show that the sand TES plant is more costly to operate than a gas-boiler based plant due to the low cost of natural gas, while the site EUI and carbon intensity can be improved. This novel system shows initial promise as a low-carbon alternative to conventional natural gas steam boilers but will require further modelling and follow-up research to improve its energy efficiency. An eventual rise in natural gas prices, and reduction of electricity prices, could improve the economic viability of this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sand Thermal Energy Storage Pilot Design (Final Report)

This report summarizes work done on developing a 10-MWhe pilot of the sand-based thermal energy storage (SandTES) technology at Alabama Power’s Plant Gaston Unit 5, an operating, supercritical coal power unit. The system will be integrated to the unit, obtaining steam to heat the sand through an air-blown fluidized-bed heat exchanger, then storing the water to be reused during discharging to produce steam that will then be vented. An electrical particle heater will also be included to provide part of the heat to the sand to provide data and learnings for commercial systems that will be fully electrically heated. Hot sand is contained in one bunker, while cold sand is housed in the other bunker, and standard solids handling equipment moves the sand around. This pilot would advance the SandTES technology to Technology Readiness Level 6 and position it for commercial readiness by 2030. This work was done in two phases: Phase I performed a conceptual study that provided Association for the Advancement of Cost Engineering (AACE) Class 5 costs and estimated performance, and then Phase II, which also involved a design update, performed a more detailed pre-front-end engineering and design study that elicited AACE Class 4 costs. Work was also done to provide estimated costs for commercial applications of the technology, assess its gaps, create its technology maturation and commercialization plans, and finally perform an Environmental Information Volume for the pilot site as a first step in the National Environmental Policy Act process.

20 FOSSIL-FUELED POWER PLANTS↗

Process Model-Based Validation of the Intensification of Biomass Fast Pyrolysis in a Fluidized Bed via Autothermal Operation

A model for the fluidized-bed pyrolysis of biomass is extended to enable the simulation of intensified autothermal operation. In this system, partial oxidation of char and pyrolysate species replaces an external heat source to supply the enthalpy of pyrolysis, greatly increasing the throughput of a given fast pyrolysis reactor. Oxidation reactions are compiled from CRECK and other literature sources and extended to cover the species found in pyrolysis products, including a derivation of the catalytic effect of ash on char combustion from experimental studies at Iowa State University (ISU). Results indicate a roughly 3-fold increase in biomass throughput for a given reactor volume at the pilot scale with minimal loss of valuable products, in agreement with published data from the 3 × 10 -2 m 3 reactor operated by ISU. Additionally, a proposal for a 250 ton/day commercial-scale biomass pyrolysis reactor is analyzed, showing that the same size reactor operated by heating the fluidizing gas externally would have only one-tenth the capacity; if operated by heating the sand externally, the sand would need to circulate at an impractical 0.7 bed volume per minute rate to maintain a 250 ton/day biomass throughput.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

Heating effects on pyrogenic organic matter mass loss and temperature in a sand matrix in a lab setting from 2022

This dataset contains data associated with the preprint “A laboratory method for simulating the effects of subsequent fires on pyrogenic organic matter at different exposure depths in a sand matrix” (https://doi.org/10.1101/2024.07.30.605814), which has been accepted for publication in the International Journal of Wildland Fire. The dataset was generated to investigate the effects of subsequent fires on preexisting pyrogenic organic matter (PyOM) at different soil depths. Specifically, we designed a laboratory method to simulate soil heating from above, applying realistic heat flux profiles (High, Low, Control) derived from jack pine (Pinus banksiana Lamb.) log burns. Using a cone calorimeter, these profiles were applied to buried jack pine PyOM (produced at 350°C) in a sand matrix pyrocosm to examine PyOM mass loss at different depths (surface, 1 cm, 5 cm). Each treatment (e.g., High heat flux at 1 cm depth) was applied once to five replicates in a pyrocosm.The dataset includes mass loss fraction of PyOM and time-series temperature profiles (measured with type K thermocouples). Additionally, calibration datasets for high and low heat flux profiles are provided, including programmed heat flux profile data and three sets of calibration results. All datasets are in .csv format and were analyzed in R using code found at https://github.com/MengmengLuo/Reburning-pyrogenic-organic-matter-A-laboratory-method-for-dosing-dynamic-heat-fluxes-from-above. This dataset supports research on PyOM transformations during subsequent fires, and methodological advancements in simulating soil heating. It can be used to explore fire-induced PyOM alterations across different fire intensities and soil depths.

54 ENVIRONMENTAL SCIENCES↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Particle-wall heat transfer in narrow-channel bubbling fluidized beds for thermal energy storage

Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.

14 SOLAR ENERGY↗

Application of physics-informed neural networks (PINNs) solution to coupled thermal and hydraulic processes in silty sands

Abstract The accurate modeling of water and heat transport in soils is crucial for both geo-environmental and geothermal engineering. Traditional modeling methods are problematic because they require well-defined boundaries and initial conditions. Recently, physics-informed neural networks (PINNs), which incorporate partial differential equations (PDEs) to solve forward and inverse problems, have attracted increasing attention in machine learning research. In this study, we applied PINNs to tackle hydraulic and thermal transport coupling forward problems in silty sands. A fully connected deep neural network was utilized for training. This neural network model leverages automatic differentiation to apply the governing equations as constraints, based on the mathematical approximations established by the neural network itself. We conducted forward problems and compared the solutions derived from PINNs with those from Finite Element Method (FEM) simulations. The forward problem results demonstrate the PINNs model’s capability in predicting hydraulic transport, heat transport, and thermal–hydraulic coupling in silty sands under various boundary conditions. The PINNs exhibited great performance in simulating the thermal–hydraulic coupling problem. The accuracy of the PINNs solutions shows its potential for simulation in geotechnical engineering.

Feng, Yuan↗

Development of Magnesium Oxysulfate Formulation for SRPPF Aqueous Recovery Liquid Solidification

The liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery Processes will be solidified into a stable form that is acceptable by Waste Isolation Pilot Plant (WIPP) for disposal. The current Aqueous Recovery flow sheet proposes to solidify the liquid effluent using a grout formula that was developed and tested for the former Waste Solidification Building process. This Portland cement based mixture results in a high pH (~13) leachate from the solidified waste form which is not acceptable to WIPP in the large quantities expected from production at SRPPF. Various cementitious materials were previously evaluated as alternative grout formulations to Portland cement and a MgO-based mix was identified as a promising alternative. A magnesium oxysulfate (MOS) cement formulation comprised of reactive magnesium oxide (MgO), anhydrous magnesium sulfate (MgSO 4 ), and sand, as a non-reactive heat sink provided good mixability, similar density to the original Portland-cement based mix, and a leachate pH of 9.4, within the assumed WIPP brine pH range. However, the MOS formulation exhibited an appreciable amount of heat generation, which resulted in premature setting of a large-scale test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of advanced diagnostic tools, models, and technoeconomic analyses for high-temperature heat transfer coefficient heat exchangers

This is a final technical report of a system designed to image fall particle receivers. High temperature heat is hard to store and move and using low cost materials, similar to sand, are ideal. However, particle-to-particle interactions can impact heat transfer mechanisms in these classes of materials. This report highlights our effects to utilize x-ray imaging to understand these dynamics.

14 SOLAR ENERGY↗

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE↗

Supporting data for "Frozen flume experiments indicate rapid permafrost riverbank erosion depends on bank roughness"

This dataset contains supporting files detailing five frozen flume experiments conducted at the Caltech Earth Surface Dynamics Laboratory to investigate rates of ablation-limited permafrost riverbank erosion under controlled conditions. Water flowed past a bank of saturated, frozen sand and ice and gradually eroded the bank by thawing pore ice and immediately entraining sand and washing it downstream. Experiments were scaled for flow hydraulics and heat transfer allowing comparisons between our results and natural permafrost riverbanks. For each experiment, we measured the initial and final sand bank topography using a Keyence laser scanner, water surface slope at 3-min intervals throughout the experiment using a Massa sonar scanner, bank erosion using 10-sec overhead timelapse imagery taken by an overhead camera, water and bank temperature using thermistors frozen into the sand bank and sampling at 2 Hz, and water discharge using an in-line flow meter. We include calibration data for the carriage (engineered by the Saint Anthony Falls Laboratory) used to make sonar and laser topography measurements. We also include calibration data for temperature sensors, water discharge measurements, and images of a regular grid placed in the flume to align overhead camera images with the carriage datum. Grain size analysis for the channel bed (gravel) was produced using a pebble count and bank sand was measured using a Camsizer X2. In addition to the five frozen experiments, we include sonar scans of water surface slope and Keyence scans of bed and bank topography for calibration experiments ran with an immobile gravel bank and bed.

54 ENVIRONMENTAL SCIENCES↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Hydro-mechanical behavior of heated bentonite buffer for geologic disposal of high-level radioactive waste: A bench-scale X-ray computed tomography investigation

The behavior of heated bentonite buffer is critical for the security and long-term performance of a geological repository for high-level radioactive waste (HLW). While laboratory column experiments have been conducted to investigate compacted bentonite and coupled THMC (thermal-hydro-mechanical and chemical) processes for a moderate temperature range of up to 100 °C, data for a higher temperature range are limited. Understanding bentonite behavior and coupled THMC processes under higher temperatures (e.g., up to 200 °C) could allow for a more economic repository design and would expand the data and knowledge base for more reliable modeling. In this study, a bench-scale experiment was conducted in a compacted bentonite column experiencing both heating up to 200 °C in the center and hydration from a sand-clay boundary surrounding the column. During the experiment run for 1.5 years, frequent X-ray computed tomography (CT) scanning of bentonite provided insights into the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. After the experiment, a comprehensive post-dismantling characterization of bentonite samples was conducted. Results showed that the bentonite hydration was axi-symmetrical despite the initial heterogeneity due to packing, confirming the ability of bentonite to seal fast flow/transport paths. Further, compared to a non-heated control experiment, the heated column showed greater CT density variations along the radial distance, indicating that homogenization of bentonite might be more difficult if a temperature gradient is maintained in the repository. Precipitation of an anhydrite layer occurred in the inner hot zone, pointing to potential concerns about salt precipitation causing canister corrosion. Ultimately, the experiments provided a high-resolution window into the strongly dynamic and coupled behavior of bentonite exposed to heating, hydration and swelling, which will be valuable for improving modeling of coupled processes, especially for the early state of a HLW repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

A Custom High-Throughput Optical Mapping Instrument for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

14 SOLAR ENERGY↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗