Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sankey diagram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Novel Results Visualization for Dynamic PSA and New Modeling Features in EMRALD

The Event Modeling Risk Assessment Linked Diagram (EMRALD) tool, developed at the Idaho National Laboratory (INL), was designed to simplify the creation of dynamic models and support various research projects. One of the primary goals of EMRALD was to provide visual methods for modeling. EMRALD consists of two main components: a web-based user interface for model development and a solve engine for running model simulations. Over time, it has evolved to meet the diverse needs of its users. Initially, EMRALD's results were simple text outputs with final key state percentages and uncertainty bounds. However, because EMRALD utilizes a three-phase discrete event simulation and tracks the paths of each simulation run leading to a key state, there is significant potential to analyze large sets of path results data, including state paths, events, and timing. Visualizing this data meaningfully posed a challenge. To address this, a novel time-based Sankey diagram was developed. EMRALD exports results data in a format that can be opened in this Sankey viewer, allowing users to visualize paths, occurrences, events, and probability data for the entire simulation run in a single diagram. Moreover, when EMRALD was first created, there were limited tools capable of meeting its graphical requirements, many of which are no longer supported. In 2024, a new web-based interface was developed using modern graphing tools, enabling additional modeling features. This paper discusses the new dynamic PSA results visualization capability and the enhanced modeling tools available in EMRALD.

97 - MATHEMATICS AND COMPUTING↗

Energy-water interdependencies across the three major United States electric grids: A multi-sectoral analysis

As water availability and timing of delivery fluctuates and the US electric grid sees rapid transformation and reconfiguration under decarbonization and resource adequacy strategies, there is a critical need for information and data that supports understanding the water-energy interdependency landscape. The United States currently lacks comprehensive data, informative visualizations, and analysis of energy-water interdependencies at scales necessary to support resource and operational decision-making. This article provides US electricity interconnection-level Sankey diagrams that show the relative reliance of water and energy across various economic sectors. A deeper analysis is additionally provided at the county level to illustrate trends and potential opportunities related to resiliency and efficiency in multi-sectoral water and energy flow distributions and intensities. We find that the electricity interconnections in the US vary dramatically in their water and energy interdependencies across applications and economic sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Facility CO2 Flow Tool (FCFT) v0.9

Facility CO2 Flow Tool assists facilities and entities to visualize their CO2 flows for accounting and decarbonization purposes. To do so, the suite offers two components – an MS Excel-based input workbook and a web-based visualization tool. The workbook serves as the input sheet, utilizing the user-provided process and equipment-level energy consumption data to calculate the corresponding CO2 emissions. The web-based tool utilizes the data from this workbook to generate a Sankey diagram. This diagram visually represents the CO2 flow originating from the fuel and electricity consumption within the facility/entity boundary.

Khan, Ovais↗

NETL Energy Related Diagrams 2024 Edition [Slides]

This illustrative report uses Sankey type diagrams to illustrates energy use and CO 2 generation within the U.S. for the year 2024. The diagrams show primary energy consumption from coal, natural gas, nuclear, petroleum, and renewables for the electric, residential, commercial, industrial, and transportation sectors; fossil fuel trade/domestic production; and CO 2 generation by fuel and end use.

20 FOSSIL-FUELED POWER PLANTS↗

NETL Energy Related Diagrams: 2023 Edition [Slides]

This illustrative report uses Sankey type diagrams to illustrates energy use and CO 2 generation within the U.S. for the year 2023. The diagrams show primary energy consumption from coal, natural gas, nuclear, petroleum, and renewables for the electric, residential, commercial, industrial, and transportation sectors; fossil fuel trade/domestic production; and CO 2 generation by fuel and end user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fall 2023 Solar Industry Update [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry. This quarter we also provide additional analysis on the domestic content of U.S. PV installations.

14 SOLAR ENERGY↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗