Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scalpel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Ultraviolet radiation as disinfection for fish surgical tools

Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelomic cavity of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When fish are implanted consecutively, as in large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. To determine the efficacy for this application, ultraviolet (UV) radiation was used to disinfect surgical tools exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica, causative agents of furunculosis, coldwater disease, bacterial kidney disease, and saprolegniasis (water mold), respectively. Four experiments were conducted to address the question of UV efficacy. In the first experiment, forceps were exposed to the three bacteria at three varying concentrations. After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods – 2, 5, or 15 min. UV radiation exposures at all durations were effective at killing all three bacteria on forceps at the highest bacteria concentrations. In the second experiment, stab scalpels, sutures, and needle holders were exposed to A. salmonicida using the same methodology as used in Experiment 1. UV radiation exposure at 5 and 15 min was effective at killing A. salmonicida on stab scalpels and sutures but not needle holders. In the third experiment, S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV radiation was effective at killing the water mold at all three exposure durations. Collectively, this study shows that UV radiation appears to provide a quick alternative disinfection technique to chemical disinfectants (e.g., ethanol) for some surgical tools. However, we do not recommend using this method for tools such as needle holders having overlapping parts or other structures that cannot be exposed directly to UV radiation

UV light, sterilization, fish surgery, disinfectio↗

The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish and have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.

Walker, Ricardo W.↗

MFANS 2024 - Dimensional Analysis Made Easy

There is a significant impact of dimensional errors in systems. Dimensional analysis is difficult due to the large size of systems. SA4U and Scalpel are practical programs which can have an impact beyond traditional software as they are able to perform precise dimensional analysis and repair C++ source code.

97 MATHEMATICS AND COMPUTING↗

What Does Competence Entail in Interventional Radiology?

Interventional radiology is a relatively new speciality and may be referred to as 'image-guided surgery without a scalpel.' Training and accreditation bodies regard interventional radiology training as being 'different' from general radiology because of the additional need for dexterity and clinical acumen. Due to the multidimensional role of an interventional radiologist, a practitioner in this discipline must have a number of the competencies of anesthetists, surgeons, and radiologists. The attributes required of an interventional radiologist are akin to those required of a surgeon. This paper gives an overview of the skills required to be a competent interventional radiologist along with a succinct introduction to methods of assessment of technical and non-technical skills.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Relationship Between Gelatin Sponge Preparation Methods and the Incidence of Intrauterine Synechia Following Uterine Artery Embolization for Postpartum Hemorrhage

Purpose: To evaluate the relationship between gelatin sponge preparation methods and the incidence of intrauterine synechia following uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: In a retrospective monocentric study, we used data from 20 consecutive UAE procedures (19 patients) for PPH, performed in 2007–2016, in which gelatin sponge had been used. The gelatin sponge was processed either into a slurry by pumping it back and forth about 10 times through two syringes connected to a three-way stopcock or into pledgets using a scalpel and small scissors to obtain pieces approximately 2 × 2 × 2 mm in size. Patient information was obtained from medical records, and the data were compared between patients treated with the slurry (n = 7) or pledgets (n = 13) forms. Due to the lack of follow-up data and hysterectomy after UAE, the sample size was 6 and 12 because 1 patient with 2 procedures was excluded. Results: The rate of intrauterine synechia was significantly higher in the slurry group (5/6, 83.3%) than that in the pledgets group (0/12, 0%; P < 0.001). In contrast, there were no significant differences in population characteristics, such as the incidence of placenta accreta, non-placental diseases, and severity of shock (DIC score, shock index, or blood loss) between the groups. Conclusions: Although non-randomization and small sample size were the two main limitations, our observations suggest that UAE using gelatin sponge slurry may be associated with a high incidence of intrauterine synechia compared to UAE using pledgets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Ablation of Biological Tissue Using Pulsed CO{sub 2} Laser

Laser scalpels are currently used as a form of laser treatment. However, their ablation mechanism has not been clarified because laser excision of biological tissue occurs over a short time scale. Biological tissue ablation generates sound (laser-induced sound). This study seeks to clarify the ablation mechanism. The state of the gelatin ablation was determined using a high-speed video camera and the power reduction of a He-Ne laser beam. The aim of this study was to clarify the laser ablation mechanism by observing laser excision using the high-speed video camera and monitoring the power reduction of the He-Ne laser beam. We simulated laser excision of a biological tissue by irradiating gelatin (10 wt%) with radiation from a pulsed CO{sub 2} laser (wavelength: 10.6 {mu}m; pulse width: 80 ns). In addition, a microphone was used to measure the laser-induced sound. The first pulse caused ablation particles to be emitted in all directions; these particles were subsequently damped so that they formed a mushroom cloud. Furthermore, water was initially evaporated by laser irradiation and then tissue was ejected.

42 ENGINEERING↗

Microsphere-chain waveguides: Focusing and transport properties

It is shown that the focusing properties of polystyrene microsphere-chain waveguides (MCWs) formed by sufficiently large spheres (D ≥ 20λ, where D is the sphere diameter and λ is the wavelength of light) scale with the sphere diameter as predicted by geometrical optics. However, this scaling behavior does not hold for mesoscale MCWs with D ≤ 10λ resulting in a periodical focusing with gradually reducing beam waists and in extremely small propagation losses. The observed effects are related to properties of nanojet-induced and periodically focused modes in such structures. The results can be used for developing focusing microprobes, laser scalpels, and polarization filters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laparoscopic Isolated Total Caudate Lobectomy for Hepatocellular Carcinoma Located in the Paracaval Portion of the Cirrhotic Liver

Background: Despite the widespread use of laparoscopic hepatectomies in past decades, laparoscopic isolated total caudate lobectomy for hepatocellular carcinoma (HCC) remains challenging,{sup 1,2} especially for patients with cirrhosis. Moreover, a laparoscopic isolated total caudate lobectomy for HCC originating in the paracaval portion of the caudate lobe is very rare. We herein present a video showing laparoscopic total caudate lobectomy for a cirrhotic patient with HCC located in the paracaval portion of the caudate lobe. Methods: A 58-year-old woman who suffered from hepatitis C virus-related cirrhosis was admitted to our institution. The preoperative computed tomography showed a 2.5 × 2.0 cm liver mass located in segment I that was very close to the right hepatic pedicle. Although her liver function was Child–Pugh A, the indocyanine green (ICG)-15 test was high at 10.9%. Right hepatectomy plus caudate lobectomy was not adopted because of the severe cirrhosis and the elevated ICG-15. Thus, laparoscopic isolated total caudate lobectomy was contemplated. Results: The patient was placed in the supine position. After full mobilization, the caudate lobe was exposed. The third porta of the liver was then dissected and the short hepatic veins were controlled with clips and LigaSure. The dissection was finished when the whole third porta of the liver was freed. Subsequently, the portal branches to the caudate lobe were ligated and cut. The combination between the left- and right-sided laparoscopic approaches was used to transect liver parenchyma. The superficial parenchyma was divided using an harmonic scalpel, while the deeper tissue was divided using a Cavitron ultrasonic aspirator (CUSA). The Pringle maneuver was used intermittently during the parenchymal transection as necessary. In the left-sided approach, the caudate lobe was resected along the left and middle hepatic vein toward the right side, to expose the dorsal semicircle of the right hepatic vein. In the right-sided approach, the resection started from the right border of the process portion to the root of the right hepatic vein in the cranial direction. Finally, the whole caudate lobe was resected and the three main hepatic veins were exposed on the cutting plane. The specimen was removed from suprapubic incision. The operative time was 300 min and the total Pringle time was 50 min. The postoperative course was uneventful. Conclusions: A laparoscopic isolated total caudate lobectomy for HCC located in the paracaval portion of the cirrhotic liver seems to be feasible and safe in selected patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

High-Speed, high-power, switching transistor

Silicon transistor rate for 200 angstroms at 400 to 600 volts combines switching speed of transistors with ruggedness, power capacity of thyristor. Transistor introduces unique combination of increased power-handling capability, unusally low saturation and switching losses, and submicrosecond switching speeds. Potential applications include high power switching regulators, linear amplifiers, chopper controls for high frequency electrical vehicle drives, VLF transmitters, RF induction heaters, kitchen cooking ranges, and electronic scalpels for medical surgery.

Carnahan, D.↗

Survival of B. Horneckiae Spores Under Ground-simulated Space Conditions

To prevent forward contamination and maintain the scientific integrity of future life detection missions, it is important to characterize and attempt to eliminate terrestrial microorganisms associated with exploratory spacecraft and landing vehicles. Among the organisms isolated from spacecraft-associated habitats, spore-forming microbes are highly resistant to various physical and chemical conditions, which include ionizing and UV radiation, desiccation and oxidative stress, and the harsh environment of outer space or planetary surfaces. Recently a radiation resistant, spore forming bacterial isolate, Bacillus horneckiae, was isolated from a clean room of the Kennedy Space Center where the Phoenix spacecraft was assembled. The exceptionally high tolerance of extreme conditions demonstrated by sporeforming bacteria highlighted the need to assess the viability of these microbes in situ (in real) space. The proposed BOSS (Biofilm Organisms Surfing Space) project aims to understand the mechanisms by which biofilm forming organisms, such as B. horneckiae, will potentially be able to withstand harsh space conditions. As previously stated, the spore producing ability of these species gives them increased survivability to harsh conditions. Some of the spores will have the protective exosporium layer artificially removed before the test to determine if the existence of this layer significantly changes the survivability during the mission. In preparation for that experiment, we analyzed spores which were exposed during a ground simulation, the EXPOSE R2 Biofilm Organisms Surfing Space (BOSS). Previous to exposure, spores were deposited onto spacecraft grade aluminum coupons in a spore suspension calculated to contain between 10(exp 7) and 10(exp 8) spores. This precursor series will be used to establish a baseline survivability function for comparison with the future flight tests during EXPOSE-R. For each coupon, a 10% polyvinyl alcohol (PVA) film was applied and peeled from the coupon to recover the spores. One hundred μl of sterile 10% PVA was applied to the surface of the coupon and allowed to dry for 1 hour at 37 C. The films were then removed using sterile scalpel and forceps and placed into a glass test tube containing 2 milliliters of sterile deionized water. The PVA film process was then repeated on each coupon one additional time to ensure recovery of the majority of spores. The second PVA film was added in the same glass tube as in the previous round. If the spores remained 100% viable, the test tubes should now contain between 5 X 10(exp 6) and 5 X 10(exp 7) spores per millimeter; however, it is expected that some loss of viability has occurred. In order to assess this loss, the number of colony forming, viable spores was counted. To count the colony forming units (CFUs), the spore containing solution was diluted in a process of 10-fold serial dilution by mixing successive solutions in a 100 microliter spore suspension to 900 microliter deionized H2O ratio. A sample dilution series revealed that 10(exp -3) and 10(exp -4) concentrations would be necessary for an accurate CFU count to be taken. For those two concentrations, a spread on a TSA plate was prepared and incubated at 32 C. For the samples exposed to UV radiation, the cell survivability was too low to establish a count from 100 microliter spread plating. Instead, no dilutions were performed and the entire 2 milliliter spore suspension was plated and incubated at 32 C. The plate's CFU counts were taken at 24 hours and 48 hours from the time of plating. At the end of the CFU counting the total surviving spores in each sample were calculated based on the number of CFUs that were observed per 100 microliters, or per 2 milliliters for the UV irradiated samples. The results of these calculations are shown in Figures 1 and 2.

cleanroom↗