Scanning techniques for random noise testing.
Scanning techniques for random noise and vibration testing of spacecraft using multiple channel accelerometer
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Scanning techniques for random noise and vibration testing of spacecraft using multiple channel accelerometer
An ultrasonic scan procedure using the pulse-echo contact configuration was employed to obtain maps of pore fraction variations in sintered silicon nitride samples in terms of ultrasonic material properties. Ultrasonic velocity, attenuation coefficient, and reflection coefficient images were obtained simultaneously over a broad band of frequencies (e.g., 30 to 110 MHz) by using spectroscopic analysis. Liquid and membrane (dry) coupling techniques and longitudinal and shear-wave energies were used. The major results include the following: Ultrasonic velocity (longitudinal and shear wave) images revealed and correlated with the extent of average through-thickness pore fraction variations in the silicon nitride disks. Attenuation coefficient images revealed pore fraction nonuniformity due to the scattering that occurred at boundaries between regions of high and low pore fraction. Velocity and attenuation coefficient images were each nearly identical for machined and polished disks, making the method readily applicable to machined materials. Velocity images were similar for wet and membrane coupling. Maps of apparent Poisson's ratio constructed from longitudinal and shear-wave velocities quantified Poisson's ratio variations across a silicon nitride disk. Thermal wave images of a disk indicated transient thermal behavior variations that correlated with observed variations in pore fraction and velocity and attenuation coefficients.
Scanning technique images spot of blue light on fundus, measures variations in reflectance of spot and compares reflectance pattern with a stored reference pattern. Method then converts the difference from stored pattern into infrared eye motion.
Chain matrix analysis of electronic boresight scanning technique for dual-plane amplitude- sensing monopulse antenna
Several applications of linear scanning of different types of objects are described; examples include double stars, satellites, the Red Spot of Jupiter and a landing site on the moon. This technique allows one to achieve a gain of about an order of magnitude in resolution over conventional photoelectric techniques; it is also effective in providing sufficient data for removing background effects and for the application of deconvolution procedures. Brief consideration is given to two-dimensional scanning, either at the telescope or of electronographic images in the laboratory. It is suggested that some of the techniques described should be given serious consideration for space applications.
Two different laser-scanning methods may be utilized. In each case scanned cylindrical bullet surface is displayed ""unwrapped'' on oscilloscope screen. Bullets are compared by photographing each display and superimposing negatives of two images. With some modifications bullets can be scanned and compared by superimposing images on screen of dual-beam oscilloscope.
A progress report on the development of a bistatic radar cross section (RCS) measurement range is presented. A technique using one parabolic reflector and a planar scanning probe antenna is analyzed. The field pattern in the test zone is computed using a spatial array of signal sources. It achieved an illumination pattern with 1 dB amplitude and 15 degree phase ripple over the target zone. The required scan plane size is found to be proportional to the size of the desired test target. Scan plane probe sample spacing can be increased beyond the Nyquist lambda/2 limit permitting constant probe sample spacing over a range of frequencies.
Computed radiation patterns for dual plane, amplitude sensing monopulse radar antenna using electronic boresight scanning device
In this paper, we describe a novel interleaved scanner for an eye-safe 3D scanning lidar system to measure aerodynamic phenomena in a wind tunnel using elastic backscatter from seeding particles. The scanner assembly consists of a rotating polygon scanner for line scanning along the fast axis, a galvanometer (galvo) scanner for scanning along the slow axis, angular position sensors and motor controllers. The polygon scanner sweeps the lidar beam at up to 10,000 lines/s across a 27 deg angular field-of-regard in the fast axis, while the galvo scanner covers an angular range of 20 deg in the slow axis. Using this scanner, the lidar can perform non-intrusive flow visualization, velocimetry, and hard target mapping at mmscale spatial resolution to a standoff range of 5 m at an update rate of 50 Hz for the full field-of-regard. An interleaved scanning methodology for the acquisition of two snapshots of 3D lidar intensity data with a 100 μs time offset is discussed. The design of the control and data acquisition electronics is described. The effects of rapid scanning on the response of a narrow field-of-view lidar are addressed. The design of the scanner is scalable and can be tailored to meet the requirements of other applications by increasing or decreasing the standoff range, angular field-of-regard and scan rate.
As more and more nonlinear estimation techniques become available, our interest is in finding out what performance improvement, if any, they can provide for practical nonlinear problems that have been traditionally solved using linear methods. In this paper we examine the problem of estimating spacecraft position using conical scan (conscan) for NASA's Deep Space Network antennas. We show that for additive disturbances on antenna power measurement, the problem can be transformed into a linear one, and we present a general solution to this problem, with the least square solution reported in literature as a special case. We also show that for additive disturbances on antenna position, the problem is a truly nonlinear one, and we present two approximate solutions based on linearization and Unscented Transformation respectively, and one 'exact' solution based on Markov Chain Monte Carlo (MCMC) method. Simulations show that, with the amount of data collected in practice, linear methods perform almost the same as MCMC methods. It is only when we artificially reduce the amount of collected data and increase the level of noise that nonlinear methods show significantly better accuracy than that achieved by linear methods, at the expense of more computation.
Two pilots' methods of looking at instruments with needle pointers in a fixed base helicopter simulation were observed. A total of 45 runs were analyzed for each pilot. The data indicated that two apparently different techniques were being used; one looking at the needle point, the other looking at a fixed spot on the instrument and reading the needle direction parafoveally. The latter technique is found to be somewhat faster with both pilots accomplishing the flying task.
The principle of a new inversion technique which uses multiple wavelength-solar UV radiation satellite measurements for determining vertical ozone profiles is described, and examples of computer simulations for 280, 300, 320, and 340 nm are discussed. Weighting functions corresponding to the sensitivity of the limb radiance to the relative ozone density at each altitude are the basis for the inversion equation, which is then solved by an iteration technique. The use of multiple wavelengths can provide more information of higher accuracy over a wider height range than those profiles recovered at a single wavelength. It is indicated that an effective range of altitude of approximately 20-70 km with a vertical resolution of 1-2 km is feasible for determining ozone profiles with an inferred profile error about three to four times larger than the measurement error within that altitude region. Ozone profile accuracy of the highest altitude region may be improved using wavelengths down to 260 nm, and inferred ozone profiles above 70 km are possible, but with a larger error.
A technique is presented for determining sound power from sound intensity measurements. Sound power from sound pressure measurements needs approximations, a specific measurement environment, and costly facilities. Sound intensity measurements are the primary quantity required to determine sound power levels, require no costly facilities, and can be made in the presence of extraneous noise. All results are presented in viewgraph format.
Aeolian abrasion is operative in many arid locations on Earth and is probably the dominant rock erosion process in the current Martian environment. Therefore, understanding the controlling parameters and rates of aeolian abrasion provides 1) insight into the stability of rocks on planetary surfaces and the environments under which the rocks abrade, and 2) a link between ventifact (a rock abraded by windblown particles) morphology and: a) abrasion conditions, b) possible ancient environments under which the rocks were abraded, and c) rock properties. promising and we plan further investigations in the wind tunnel and field. Our intent here is to discuss the basic technique, initial results, and upcoming plans.
In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible
Multispectral scanner and thematic mapper (TM) data from Landsat satellites are discussed in terms of the perceived 'simultaineity' of the images, which are obtained by scanning techniques. Scanning the scenes ensures that the data points of the images are actually sequential, even if the scan is performed at rates that are fast relative to the motion of the spacecraft. The last datum gathered by the MSS is, in fact, taken 29 sec after the first, witih a 56 m distance being present between pixels. The spacing in uneven from band to band on the TM and analyses of the data to produce an image requires consideration of nonfixed time relationships for different locations on the scan within and among the bands. Additionally, corrective measures must be taken to compensate for instrument jitter and attitude changes.
This project details the design and analysis of a structure to replace the interface of the P-3B nadir port with an optimized interface for science installations. A new nadir port plug has been designed to replace the OEM (Original Equipment Manufacturer) plug (Lockheed PN 910169) currently used in Nadir ports 1 and 2 on the NASA P-3B aircraft. The plug consists of a milled frame that can be outfitted with customizable flat plates to meet a broad range of science needs. The frame slides into place using the existing P-3B rail system using a lever and tie-rod assembly. The seal interface will contact the Fuselage skin of the aircraft and consists of a bulb E-seal that is riveted around the perimeter of the frame. The flat plate (20 inches x 31 inches) provides a large profile that can be outfitted based on science mission goals and requirements to attach multiple instruments. This is a significant increase to the aircraft capability. Previously, the OEM plug had to be modified to hold very small plates, windows, or instruments limiting the use of the ports.There were several challenges for this project that included a constrained schedule, lack of historical references, and reverse engineering. The unusually tight schedule for design, manufacture, and install limited potential approaches. In addition, design of a new interface to replace the existing plug, on an aircraft designed in the 1960's by Lockheed for the Navy with little to no documentation, required substantial reverse engineering. In order to accomplish this, a suitable method to determine interface requirements with the aircraft had to be solved. After several iterations, the solution was to implement laser scanning techniques to scan the aircraft and the OEM plug and generate a 3D model to capture the design envelope. The structure is designed to maintain a positive margin of safety when subjected to the inertial, pressure, and aerodynamic load requirements for an external installation on the P-3B, as described in the Wallops' P-3B Design Requirements 548-RQMT-0001 Rev. A . A finite element model is created in FEMAP (Finite Element Modeling And Postprocessing) and is run through NX Nastran solver to analyze the structure. After several iterations of analysis, the structure was enveloped to hold 115 pounds evenly distributed on the plate.
A summary description is made of spin-scanning devices for various space missions. Compared to television, scan-imaging has remarkable advantages and these are listed.