Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Supine Craniospinal Irradiation Using a Proton Pencil Beam Scanning Technique Without Match Line Changes for Field Junctions

Purpose: To propose and validate a craniospinal irradiation approach using a proton pencil beam scanning technique that overcomes the complexity of the planning associated with feathering match lines. Methods and Materials: Ten craniospinal irradiation patients had treatment planned with gradient dose optimization using the proton pencil beam scanning technique. The robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in the longitudinal direction and was compared with the original nonshifted plan with metrics of conformity number, homogeneity index, and maximal cord doses. An anthropomorphic phantom study using film measurements was carried out on a plan with 5-cm junction length. To mimic setup errors in the phantom study, fields were recalculated with isocenter shifts of 1, 3, 5, and 10 mm longitudinally, and compared with the original plans and measurements. Results: Uniform dose coverage to the entire target volumes was achieved using the gradient optimization approach with averaged junction lengths of 6.7 ± 0.5 cm. The average conformity number and homogeneity index equaled 0.78 ± 0.03 and 1.09 ± 0.01, respectively. Setup errors of 3 mm per field (6 mm in worst-case scenario) caused on average 4.6% lower conformity number 2.5% higher homogeneity index and maximal cord dose of 4216.1 ± 98.2 cGy. When the junction length was 5 cm or longer, setup errors of 6 mm resulted in up to 12% dosimetric deviation. Consistent results were reached between film measurements and planned dose profiles in the junction area. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the proton craniospinal irradiation treatment with matched proton pencil beam scanning fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust to longitudinal setup errors compared to conventional feathering methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Third-order nonlinear optical properties of Bi{sub 2}S{sub 3} nanocrystals doped in sodium borosilicate glass studied with Z-scan technique

Research highlights: {yields} Sol-gel method to realize the synthesis of Bi{sub 2}S{sub 3} nanocrystals doped in the glass. {yields} High dispersion and narrow distribution of Bi{sub 2}S{sub 3} nanocrystals in the glass. {yields}Z-scan technique employed for nonlinear optical properties of the glass. {yields} Observation that an obvious third-order optical nonlinear properties in the glass. -- Abstract: The third-order nonlinear optical properties of Bi{sub 2}S{sub 3} nanocrystals doped in sodium borosilicate glass are measured by Z-scan technique. The microstructures of the glass are characterized by means of X-ray diffraction, transmission electron microscopy, scanning transmission electron microscopy, energy dispersion X-ray spectra, and high-resolution transmission electron microscopy. The results show that the Bi{sub 2}S{sub 3} nanocrystals ranging from 10 to 30 nm are determined to be of the orthorhombic crystalline phase, and the third-order optical nonlinear refractive index {gamma}, absorption coefficient {beta}, and susceptibility {chi}{sup (3)} of the glass are determined to be 2.56 x 10{sup -16} m{sup 2} W{sup -1}, 4.13 x 10{sup -10} mW{sup -1}, and 1.43 x 10{sup -10} esu, respectively.

36 MATERIALS SCIENCE↗

Nonlinear optical characterization of graphite oxide thin film by open aperture Z-scan technique

In this paper we explore the structural characterization of graphite oxide powder prepared from graphite powder by oxidation via modified Hummers method. The nonlinear optical properties of the spin coated graphite oxide thin film is also explored by open aperture Z-Scan technique. Structural and physiochemical properties of the samples were investigated with the help of Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopy (Raman).The results of FT-IR and Raman spectroscopy showed that the graphite is oxidized by strong oxidants and the oxygen atoms are introduced into the graphite layers forming C=C, O-H and –C-H groups. The synthesized sample has good crystalline nature with lesser defects. The nonlinear optical property of GO thin film was studied by open aperture Z-Scan technique using Q-switched Nd-Yag Laser at 532 nm. The Z-scan plot showed that the investigated GO thin film has saturable absorption behavior. The nonlinear absorption coefficient and saturation intensity were also estimated to explore its applications in Q switched mode locking laser systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique

Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key 'spiral-scanning' technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the 'north pole' to the 'south pole'. The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the 'optimal' outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large three-photon absorption in Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} films studied using Z-scan technique

Large picosecond nonlinearities in Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} thin films, grown at different temperatures in situ on (100) MgO substrates using rf magnetron sputtering technique, were studied using the Z-scan technique. The nonlinear absorption mechanism, studied near 800 nm using approx2 and 25 ps pulses, switched from reverse saturable absorption type in the films deposited at temperature<600 deg. C to three-photon absorption (3PA) in the films deposited at temperature>600 deg. C. The magnitude of the 3PA coefficient was estimated to be approx10{sup -21} cm{sup 3}/W{sup 2}. Two-photon absorption (2PA) was the dominant mechanism recorded with approx6 ns pulses. The observed behavior is correlated with morphological and crystallographic texture of the films. The linear refractive index and optical band gap of the films have also been calculated and these show a strong dependence on the substrate temperature.

36 MATERIALS SCIENCE↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-CD-207-05: A Novel Digital Tomosynthesis System Using Orthogonal Scanning Technique: A Feasibility Study

Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-ray projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various on-line clinical applications.

60 APPLIED LIFE SCIENCES↗

Optimizing 4d Emittance Measurements Using the Pinhole Scan Technique

Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.

42 ENGINEERING↗

Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear optical characterization of transparent thin films by the Z-scan technique

We report experimental characterization of a very small rectangular phase shift (<0.3 rad) obtained from the far-field diffraction patterns using a closed aperture Z-scan technique. The numerical simulations as well as the experimental results reveal a peak-valley configuration in the far-field normalized transmittance, allowing us to determine the sign of the dephasing. The conditions necessary to obtain useful Z-scan traces are discussed. We provide simple linear expressions relating the measured signal to the phase shift. A very good agreement between calculated and experimental Z-scan profiles validates our approach. We show that a very well known nonlinear characterization technique can be extended for linear optical parameter estimation (as refractive index or thickness).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of nonlinear refraction of organic dye by Z-scan technique using He-Ne laser

Laser induced third-order nonlinear optical responses of Brilliant Green solution has been investigated by utilizing single beam Z-scan technique with a continuous-wave He-Ne laser radiation at 632.8 nm. It was observed that the material exhibits self-defocusing type optical nonlinearity. The measurements of nonlinear refraction were carried out at different dye concentrations and found that the increase in solution concentration leads to the linear increase of the nonlinear refractive index. The experimental results confirm great potential of the Brilliant Green for the application in nonlinear optical devices.

36 MATERIALS SCIENCE↗

Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematic investigation of complex samples containing both soft and hard materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparative study on the optical limiting properties of different nano spinel ferrites with Z-scan technique

Highlights: ► First report in which the optical limiting properties of five different nano spinel ferrites are compared. ► The obtained nonlinearity fits to a two-photon like absorption process. ► Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. ► A size dependent optical limiting response is obtained. ► Among the investigated ferrites, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. -- Abstract: We report the optical limiting properties of five different spinel ferrites, NiFe{sub 2}O{sub 4}, Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}, ZnFe{sub 2}O{sub 4}, Ni{sub 0.5}Co{sub 0.5}Fe{sub 2}O{sub 4}, and CoFe{sub 2}O{sub 4} with an average particle grain size of 8 nm. The optical limiting properties are investigated using the open aperture Z-scan technique. The obtained nonlinearity fits to a two-photon like absorption process. Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. The optical limiting response is also studied against particle size and the nonlinearity is found to increase with increasing particle size within the range of our investigations. On comparing the optical limiting properties, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. To the best of our knowledge, this is the first report where the optical limiting properties of spinel ferrites are compared.

36 MATERIALS SCIENCE↗

SU-E-T-621: Analysis of Robustness of Proton Pencil Beam Scanning Technique for Delivery of Craniospinal Irradiation

Purpose: To investigate the robustness and safety of craniospinal irradiation (CSI) planned with a proton pencil beam scanning (PBS) technique which overcomes the complexity of the planning associated with feathering match lines. Methods: Six CSI patients were planned with gradient-dose matching using PBS technique. Uniform dose coverage to the entire target volumes was achieved with averaged junction lengths of 6.9±0.3 cm. Robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in longitudinal direction and compared with the original non-shifted plan with metrics of conformity number (CN) and homogeneity index (HI). An anthropomorphic phantom study using film measurements was also carried out on a plan with 5 cm junction length. Results: For a given junction length, the dose errors were directly proportional to the setup errors. Setup errors of 3 mm from each field caused on average 3.5% lower CN and 2.1% higher HI. Minimal D95% to PTV and D98% to CTV were reduced by 2.2%±1.5% and 2.8%±1.7% respectively. A drop of maximal 6.8%±5.5% on the minimal dose to the cribriform plate was also observed. When the junction length was 5cm or longer, these 3mm setup errors from each field resulted in up to 12% dose errors. Consistent results were reached between film measurements and planned dose profiles in the junction area. Due to near-zero exit doses beyond the target volume, sparing of anterior organs such as heart, liver, lung and kidney were observed. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the CSI treatment with matched proton fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust and safe to longitudinal setup errors compared to conventional feathering methods.

60 APPLIED LIFE SCIENCES↗

First measurement of traverse beam optics for the Fermilab Muon Campus using a magnet scanning technique

In the following years the Fermilab Muon Campus will deliver highly polarized muon beams to the storage ring of the Muon g-2 Experiment. The transmission fraction of the storage ring has been shown to depend strongly on the transverse optics of the injected beam. Unfortunately, the current diagnostics in the Muon Campus allow only measurement of the beam configuration space which limits how well propagation can be predicted. This work demonstrates an experimental technique based on a conventional magnet scan to obtain the Twiss parameters at a point, using only beam profiles such that installation of new equipment is not required. A proof-of-principle experiment is presented which shows that this new method is applicable to the Muon Campus, offering a viable approach to optimization of injection in the Muon g-2 Experiment.

43 PARTICLE ACCELERATORS↗

Assessment of Early Toxicity and Response in Patients Treated With Proton and Carbon Ion Therapy at the Heidelberg Ion Therapy Center Using the Raster Scanning Technique

Puropose: To asses early toxicity and response in 118 patients treated with scanned ion beams to validate the safety of intensity-controlled raster scanning at the Heidelberg Ion Therapy Center. Patients and Methods: Between November 2009 and June 2010, we treated 118 patients with proton and carbon ion radiotherapy (RT) using active beam delivery. The main indications included skull base chordomas and chondrosarcomas, salivary gland tumors, and gliomas. We evaluated early toxicity within 6 weeks after RT and the initial clinical and radiologic response for quality assurance in our new facility. Results: In all 118 patients, few side effects were observed, in particular, no high numbers of severe acute toxicity were found. In general, the patients treated with particle therapy alone showed only a few single side effects, mainly Radiation Therapy Oncology Group/Common Terminology Criteria grade 1. The most frequent side effects and cumulative incidence of single side effects were observed in the head-and-neck patients treated with particle therapy as a boost and photon intensity-modulated RT. The toxicities included common radiation-attributed reactions known from photon RT, including mucositis, dysphagia, and skin erythema. The most predominant imaging responses were observed in patients with high-grade gliomas and those with salivary gland tumors. For skull base tumors, imaging showed a stable tumor outline in most patients. Thirteen patients showed improvement of pre-existing clinical symptoms. Conclusions: Side effects related to particle treatment were rare, and the overall tolerability of the treatment was shown. The initial response was promising. The data have confirmed the safe delivery of carbon ions and protons at the newly opened Heidelberg facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗