Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scattering, Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiple scattered radiation emerging from Rayleigh and continental haze layers. I - Radiance, polarization, and neutral points

The matrix operator method was used to calculate the polarization of radiation scattered on layers of various optical thicknesses, with results compared for Rayleigh scattering and for scattering from a continental haze. In both cases, there are neutral points arising from the zeros of the polarization of single scattered photons at scattering angles of zero and 180 degrees. The angular position of these Rayleigh-like neutral points (RNP) in the sky shows appreciable variation with the optical thickness of the scattering layer for a Rayleigh phase matrix, but only a small variation for haze L phase matrix. Another type of neutral point exists for non-Rayleigh phase functions that is associated with the zeros of the polarization for single scattering which occurs between the end points of the curve. A comparison of radiances calculated from the complete theory of radiative transfer using Stokes vectors with those obtained from the scalar theory shows that differences of the order of 23% may be obtained for Rayleigh scattering, while the largest difference found for a haze L phase function was of the order of 0.1%.

Kattawar, G. W.↗

The inverse problem for radiation scattering

A brief survey of recent theoretical progress on the inverse scattering problem for radiation scattering from reflective boundaries and variable indices of refraction. The theory of radiation scattering is concerned primarily with the far-field relations between incident and scattered radiation in the presence of a scattering object. The primary, or direct, problem of this theory is to develop quantitative information about these scattering relations from a knowledge of the scattering object. The secondary, or inverse, problem, on the other hand, is to determine the nature of the object from an analysis of the scattering relations.

Prosser, R. T.↗

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synchrotron-based Scattered Radiation from Phantom Materials used in X-ray CT

Synchrotron-based scattered radiation form low-contrast phantom materials prepared from polyethylene, polystyrene, nylon, and Plexiglas is used as test objects in X-ray CT was examined with 8, 10 and 12 keV X-rays. These phantom materials of medical interest will contains varying proportions of low atomic number elements. The assessment will allowed us to estimate the fluorescence to total scattered radiation. Detected the fluorescence spectra and the associated scattered radiation from calcium hydroxyapatite phantom with 8, 10 and 12 keV synchrotron X-rays. Samples with Bonefil (60% and 70% of calcium hydroxyapatite) and Bone cream (35-45% of calcium hydroxyapatite), were used. Utilized the X-ray micro-spectroscopy beamline facility, X27A, available at NSLS, BNL, USA. The primary beam with a spot size of the order of {approx}10 {micro}m, has been used for focusing. With this spatial resolution and high flux throuput, the synchrotron-based scattered radiation from the phantom materials were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector.

58 GEOSCIENCES↗

The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-207B-09: Scatter Radiation Measurement From a Digital Breast Tomosynthesis System and Its Impact On Shielding Consideration

Purpose: To accurately measure the scatter radiation from a Hologic digital breast tomosynthesis (DBT) system and to provide updated scatter distribution to guide radiation shielding calculation for DBT rooms. Methods: A high sensitivity GOS-based linear detector was used to measure the angular distribution of scatter radiation from a Hologic Selenia Dimensions DBT system. The linear detector was calibrated for its energy response of typical DBT spectra. Following the NCRP147 approach, the measured scatter intensity was normalized by the primary beam area and primary air kerma at 1m from the scatter phantom center and presented as the scatter fraction. Direct comparison was made against Simpkin’s initial measurement. Key parameters including the phantom size, primary beam area, and kV/anode/target combination were also studied. Results: The measured scatter-to-primary-ratio and scatter fraction data closely matched with previous data from Simpkin. The measured data demonstrated the unique nonisotropic distribution of the scattered radiation around a Hologic DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous local survey, the scatter air kerma at 1m from the phantom center for wall/door is 0.018mGy/patient, for floor is 0.164mGy/patient, and for ceiling is 0.037mGy/patient. Conclusion: Comparing to Simpkin’s previous data, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload, added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP147 is still sufficient for the Hologic DBT system given the workload from a previous local survey. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

60 APPLIED LIFE SCIENCES↗

Method for Describing the Angular Distribution of Optical Radiation Scattered by a Monolayer of Ordered Spherical Particles (Normal Illumination)

We have developed a method for describing the angular distribution of intensity of radiation scattered by a monolayer of homogeneous spatially ordered monodisperse spherical particles normally illuminated by a plane circularly polarized electromagnetic wave. The method is based on the quasicrystalline approximation (QCA) of the theory of multiple scattering of waves (TMSW) using the multipole expansion of fields and the tensor Green function in vectorial spherical wavefunctions. The method is applied for analyzing the characteristics of radiation scattered by a partially ordered monolayer and a monolayer with a nonideal lattice. The results of calculations are compared with the available experimental data on the position of the first-order diffraction peak on the angular and spectral dependences of the intensity of radiation scattered by a closely packed monolayer with a nonideal triangular lattice of SiO{sub 2} particles. Good conformity of the results has been established.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slow gamma photon with a doublet structure: Time delay via a transition from destructive to constructive interference of collectively scattered radiation with the incoming photon

Single gamma photon propagation in a dense absorptive medium with two widely spaced resonances is experimentally studied. After an initial fast decay, a revival of the photon amplitude in the form of a bump, exceeding the probability amplitude of the incident photon, is observed. The irradiation time of this bump delays approximately by the lifetime of the excited nuclei in the absorber. This effect is explained by the interference of the incoming radiation with the collectively scattered radiation, the phase of which is modulated with the frequency of the doublet splitting. Initially, the destructive interference changes to a constructive one, distinguishing the storage and retrieval stages of the photon propagation in a dense medium, i.e., the collective absorption and collective re-emission processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Atmospheric Aerosol Characteristics from the Polarization of Scattered Radiation

Aerosols affect the polarization of radiation in scattering, hence measured polarization can be used to infer the nature of the particles. Size distribution, particle shape, real and absorption parts of the complex refractive index affect the scattering. From Lorenz-Mie calculations of the 4-Stokes parameters as a function of scattering angle for various wavelengths the following polarization parameters were plotted: total intensity, intensity of polarization in plane of observation, intensity perpendicular to the plane of observation, polarization ratio, polarization (using all 4-Stokes parameters), plane of the polarization ellipse and its ellipticity. A six-component log-Gaussian size distribution model was used to study the effects of the nature of the polarization due to variations in the size distribution and complex refractive index. Though a rigorous inversion from measurements of scattering to detailed specification of aerosol characteristics is not possible, considerable information about the nature of the aerosols can be obtained. Only single scattering from aerosols was used in this paper. Also, the background due to Rayleigh gas scattering, the reduction of effects as a result of multiple scattering and polarization effects of possible ground background (airborne platforms) were not included.

Harris, F. S., Jr.↗

Azimuthal anisotropy of the scattered radiation in grazing incidence X-ray fluorescence

The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-ray fluorescence detection sensitivities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-49: Simulation Study for Removing Scatter Radiation in Cesium-Iodine Based Flat Panel Detector System

Purpose: This study aims to identify the feasibility of a novel cesium-iodine (CsI)-based flat-panel detector (FPD) for removing scatter radiation in diagnostic radiology. Methods: The indirect FPD comprises three layers: a substrate, scintillation, and thin-film-transistor (TFT) layer. The TFT layer has a matrix structure with pixels. There are ineffective dimensions on the TFT layer, such as the voltage and data lines; therefore, we devised a new FPD system having net-like lead in the substrate layer, matching the ineffective area, to block the scatter radiation so that only primary X-rays could reach the effective dimension.To evaluate the performance of this new FPD system, we conducted a Monte Carlo simulation using MCNPX 2.6.0 software. Scatter fractions (SFs) were acquired using no grid, a parallel grid (8:1 grid ratio), and the new system, and the performances were compared.Two systems having different thicknesses of lead in the substrate layer—10 and 20μm—were simulated. Additionally, we examined the effects of different pixel sizes (153×153 and 163×163μm) on the image quality, while keeping the effective area of pixels constant (143×143μm). Results: In case of 10μm lead, the SFs of the new system (∼11%) were lower than those of the other system (∼27% with no grid, ∼16% with parallel grid) at 40kV. However, as the tube voltage increased, the SF of new system (∼19%) was higher than that of parallel grid (∼18%) at 120kV. In the case of 20μm lead, the SFs of the new system were lower than those of the other systems at all ranges of the tube voltage (40–120kV). Conclusion: The novel CsI-based FPD system for removing scatter radiation is feasible for improving the image contrast but must be optimized with respect to the lead thickness, considering the system’s purposes and the ranges of the tube voltage in diagnostic radiology. This study was supported by a grant(K1422651) from Institute of Health Science, Korea University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical, experimental and numerical methods for investigating the characteristics of laser radiation scattered in the integrated-optical waveguide with three-dimensional irregularities

We consider theoretical, experimental and numerical methods which make it possible to analyse the key characteristics of laser radiation scattered in the integrated-optical waveguide with three-dimensional irregularities. The main aspects of the three-dimensional vector electrodynamic problem of waveguide scattering are studied. The waveguide light scattering method is presented and its main advantages over the methods of single scattering of laser radiation are discussed. The experimental setup and results of measurements are described. Theoretical and experimental results confirming the validity of the vector theory of three-dimensional waveguide scattering of laser radiation developed by the author are compared for the first time. (fiber and integrated optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Radiation Scattering by Dust in Mars Entry

The impact of gas phase radiation scattering by dust particle presence in Mars entry scenarios is assessed using a suite of numerical tools. A hypersonic gas and dilute particle multiphase flow is simulated using a mixed continuum model and an efficient size distribution quadrature scheme. Radiative transport is simulated with a hybrid ray-tracing and P1 spherical harmonics model. The NASA HARA radiation code and a Lorentz-Mie scattering model are used to predict the gas-particle mixture radiative properties. Application of the numerical suite to a representative case based on the Mars 2020 entry shows that, even at conditions in excess of the strongest recorded dust storm, the augmentation in surface radiative heat flux due to scattering alone is lower than 1%, and therefore negligible. Predictions with even higher dust loading conditions confirm that even highly uncertain dust mass profiles are unlikely to be a concern for the scattering augmentation mechanism.

Andrew Hinkle↗

Neutron and synchrotron radiation scattering by nonpolar magnetic fluids

The complex approach (which comprises different physical methods, including neutron and synchrotron radiation scattering) is justified in the structural analysis of magnetic fluids (MFs). Investigations of MFs based on nonpolar organic solvents with magnetite nanoparticles (2-20 nm in size) coated by various monocarboxylic acids have been performed. It is shown that the use of saturated linear acids with various alkyl chain (C12-C18) lengths instead of unsaturated oleic acid (alkyl chain C18 with a kink in the middle due to the double bond in the cis-configuration) in the classical stabilization procedure for the given type of magnetic fluids leads to a decrease in the mean size and polydispersity of nanoparticles in the final systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗