Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scattering, Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synchrotron-based Scattered Radiation from Phantom Materials used in X-ray CT

Synchrotron-based scattered radiation form low-contrast phantom materials prepared from polyethylene, polystyrene, nylon, and Plexiglas is used as test objects in X-ray CT was examined with 8, 10 and 12 keV X-rays. These phantom materials of medical interest will contains varying proportions of low atomic number elements. The assessment will allowed us to estimate the fluorescence to total scattered radiation. Detected the fluorescence spectra and the associated scattered radiation from calcium hydroxyapatite phantom with 8, 10 and 12 keV synchrotron X-rays. Samples with Bonefil (60% and 70% of calcium hydroxyapatite) and Bone cream (35-45% of calcium hydroxyapatite), were used. Utilized the X-ray micro-spectroscopy beamline facility, X27A, available at NSLS, BNL, USA. The primary beam with a spot size of the order of {approx}10 {micro}m, has been used for focusing. With this spatial resolution and high flux throuput, the synchrotron-based scattered radiation from the phantom materials were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector.

58 GEOSCIENCES↗

The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-207B-09: Scatter Radiation Measurement From a Digital Breast Tomosynthesis System and Its Impact On Shielding Consideration

Purpose: To accurately measure the scatter radiation from a Hologic digital breast tomosynthesis (DBT) system and to provide updated scatter distribution to guide radiation shielding calculation for DBT rooms. Methods: A high sensitivity GOS-based linear detector was used to measure the angular distribution of scatter radiation from a Hologic Selenia Dimensions DBT system. The linear detector was calibrated for its energy response of typical DBT spectra. Following the NCRP147 approach, the measured scatter intensity was normalized by the primary beam area and primary air kerma at 1m from the scatter phantom center and presented as the scatter fraction. Direct comparison was made against Simpkin’s initial measurement. Key parameters including the phantom size, primary beam area, and kV/anode/target combination were also studied. Results: The measured scatter-to-primary-ratio and scatter fraction data closely matched with previous data from Simpkin. The measured data demonstrated the unique nonisotropic distribution of the scattered radiation around a Hologic DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous local survey, the scatter air kerma at 1m from the phantom center for wall/door is 0.018mGy/patient, for floor is 0.164mGy/patient, and for ceiling is 0.037mGy/patient. Conclusion: Comparing to Simpkin’s previous data, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload, added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP147 is still sufficient for the Hologic DBT system given the workload from a previous local survey. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

60 APPLIED LIFE SCIENCES↗

Method for Describing the Angular Distribution of Optical Radiation Scattered by a Monolayer of Ordered Spherical Particles (Normal Illumination)

We have developed a method for describing the angular distribution of intensity of radiation scattered by a monolayer of homogeneous spatially ordered monodisperse spherical particles normally illuminated by a plane circularly polarized electromagnetic wave. The method is based on the quasicrystalline approximation (QCA) of the theory of multiple scattering of waves (TMSW) using the multipole expansion of fields and the tensor Green function in vectorial spherical wavefunctions. The method is applied for analyzing the characteristics of radiation scattered by a partially ordered monolayer and a monolayer with a nonideal lattice. The results of calculations are compared with the available experimental data on the position of the first-order diffraction peak on the angular and spectral dependences of the intensity of radiation scattered by a closely packed monolayer with a nonideal triangular lattice of SiO{sub 2} particles. Good conformity of the results has been established.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slow gamma photon with a doublet structure: Time delay via a transition from destructive to constructive interference of collectively scattered radiation with the incoming photon

Single gamma photon propagation in a dense absorptive medium with two widely spaced resonances is experimentally studied. After an initial fast decay, a revival of the photon amplitude in the form of a bump, exceeding the probability amplitude of the incident photon, is observed. The irradiation time of this bump delays approximately by the lifetime of the excited nuclei in the absorber. This effect is explained by the interference of the incoming radiation with the collectively scattered radiation, the phase of which is modulated with the frequency of the doublet splitting. Initially, the destructive interference changes to a constructive one, distinguishing the storage and retrieval stages of the photon propagation in a dense medium, i.e., the collective absorption and collective re-emission processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Azimuthal anisotropy of the scattered radiation in grazing incidence X-ray fluorescence

The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-ray fluorescence detection sensitivities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-49: Simulation Study for Removing Scatter Radiation in Cesium-Iodine Based Flat Panel Detector System

Purpose: This study aims to identify the feasibility of a novel cesium-iodine (CsI)-based flat-panel detector (FPD) for removing scatter radiation in diagnostic radiology. Methods: The indirect FPD comprises three layers: a substrate, scintillation, and thin-film-transistor (TFT) layer. The TFT layer has a matrix structure with pixels. There are ineffective dimensions on the TFT layer, such as the voltage and data lines; therefore, we devised a new FPD system having net-like lead in the substrate layer, matching the ineffective area, to block the scatter radiation so that only primary X-rays could reach the effective dimension.To evaluate the performance of this new FPD system, we conducted a Monte Carlo simulation using MCNPX 2.6.0 software. Scatter fractions (SFs) were acquired using no grid, a parallel grid (8:1 grid ratio), and the new system, and the performances were compared.Two systems having different thicknesses of lead in the substrate layer—10 and 20μm—were simulated. Additionally, we examined the effects of different pixel sizes (153×153 and 163×163μm) on the image quality, while keeping the effective area of pixels constant (143×143μm). Results: In case of 10μm lead, the SFs of the new system (∼11%) were lower than those of the other system (∼27% with no grid, ∼16% with parallel grid) at 40kV. However, as the tube voltage increased, the SF of new system (∼19%) was higher than that of parallel grid (∼18%) at 120kV. In the case of 20μm lead, the SFs of the new system were lower than those of the other systems at all ranges of the tube voltage (40–120kV). Conclusion: The novel CsI-based FPD system for removing scatter radiation is feasible for improving the image contrast but must be optimized with respect to the lead thickness, considering the system’s purposes and the ranges of the tube voltage in diagnostic radiology. This study was supported by a grant(K1422651) from Institute of Health Science, Korea University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical, experimental and numerical methods for investigating the characteristics of laser radiation scattered in the integrated-optical waveguide with three-dimensional irregularities

We consider theoretical, experimental and numerical methods which make it possible to analyse the key characteristics of laser radiation scattered in the integrated-optical waveguide with three-dimensional irregularities. The main aspects of the three-dimensional vector electrodynamic problem of waveguide scattering are studied. The waveguide light scattering method is presented and its main advantages over the methods of single scattering of laser radiation are discussed. The experimental setup and results of measurements are described. Theoretical and experimental results confirming the validity of the vector theory of three-dimensional waveguide scattering of laser radiation developed by the author are compared for the first time. (fiber and integrated optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron and synchrotron radiation scattering by nonpolar magnetic fluids

The complex approach (which comprises different physical methods, including neutron and synchrotron radiation scattering) is justified in the structural analysis of magnetic fluids (MFs). Investigations of MFs based on nonpolar organic solvents with magnetite nanoparticles (2-20 nm in size) coated by various monocarboxylic acids have been performed. It is shown that the use of saturated linear acids with various alkyl chain (C12-C18) lengths instead of unsaturated oleic acid (alkyl chain C18 with a kink in the middle due to the double bond in the cis-configuration) in the classical stabilization procedure for the given type of magnetic fluids leads to a decrease in the mean size and polydispersity of nanoparticles in the final systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser radiation scattering from the wires and fibers of imploding arrays on the Angara-5-1 facility

A method is developed for measurements of laser radiation scattering by wires and fibers in different types of imploding arrays in the initial stage of plasma production at discharge currents per wire of up to 2 kA for aluminum arrays and up to 8 kA for tungsten arrays. The experiments were carried out on the Angara-5-1 facility at a current density in the wires of 10{sup 8} A/cm{sup 2} and current growth rate of {approx}10{sup 13} A/s. It is found that the indicatrix of laser radiation reflected from the wires (fibers) in cylindrical and conical arrays is modified at currents of 0.1-10 kA per wire (fiber). The experimental data on the reflection and scattering of laser radiation from wires and fibers are compared with the results of numerical simulations of their electric explosion in vacuum. It is proposed that the change in the reflection indicatrix of laser radiation is caused by the onset of thermal instabilities. The typical size of density and temperature inhomogeneities on the wire surface is in a range of 10-20 {mu}m, which probably results in a transition from specular to diffuse reflection of laser radiation. A simultaneous abrupt (over 2-3 ns) reduction in the reflection intensity from several wires of an array indicates a homogeneous distribution of the discharge current over the irradiated wires. This closes the issue of the quality of the contact between the wires and the electrodes. The obtained experimental information is of considerable importance for the development of numerical codes for simulations of the implosion of wire arrays and the refinement of the wire parameters in the initial stage of plasma production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Porosity and structural parameters of Karelian shungites according to the data of small-angle synchrotron radiation scattering and microscopy

The nanoporosity and structure of natural carbons has been investigated on the example of Karelian carbon-rich shungites by comparing the data of small-angle synchrotron radiation scattering and highresolution microscopy. The analysis of small-angle scattering data is based on the model of scattering spheres with lognormal size distribution. It is found that the structure of samples from the Maksovo and Zazhogino deposits subjected to high temperatures in the geological medium and (also to a lesser extent) a sample from the Shunga deposit can be described as an aggregation of polydisperse scattering spheres with lognormal size distribution; the characteristic scatterer size is determined for them. A comparison with microscopy data shows that these scatterers are mainly associated with pores, and the character of their size distribution is similar to that previously established for nanoglobules in schungites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photon Radiation Scatter from Heterogeneous Shields using Green's Functions

The effect of shielding on ionizing photon radiation can be estimated using radiation transport simulations. This report covers the methodology and implementation of using Green's Functions to pre-compute this effect, which allows the radiation field exiting a variety of shielding configurations to be quickly computed. It also covers a weighting function that makes a relatively small pre-computed library applicable to a large variety of heterogeneous shields. The method enables rapid computation of the intensity versus energy for scattered radiation exiting a variety of shield materials and thicknesses without running a full transport simulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗

Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

61 RADIATION PROTECTION AND DOSIMETRY↗

Note: Mechanical etching of atomic force microscope tip and microsphere attachment for thermal radiation scattering enhancement

This Note describes a mechanical etching technique which can be used to prepare silicon tips used in atomic force microscopy apparatus. For such devices, dedicated tips with specific shapes are now commonly used to probe surfaces. Yet, the control of the tip morphology where characteristic scales are lower than 1 μm remains a real challenge. Here, we detail a controlled etching process of AFM probes apex allowing micrometer-sized sphere attachment. The technique used and influent parameters are discussed and SEM images of the achieved tips are given. Deceptive problems and drawbacks that might occur during the process are also covered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent effects in the incoherent channel of resonant radiation scattering from excited atoms

Scattering of a resonance electromagnetic field from excited atoms cannot be described by the semiclassical theory of radiation operating with nonquantized electromagnetic fields. Field quantization effects are manifested in this case on the macroscopic level and lead to evolution of statistical properties of radiation in the course of scattering. It is found that a combined process coupling elastic scattering from an atom and induced emission from the same atom, which cannot be studied by the methods of the standard perturbation theory, plays a significant role in this effect. The process of combined scattering in extended media exhibits coherent properties that cannot be described by the standard refractive index.

74 ATOMIC AND MOLECULAR PHYSICS↗