Low cost scroll compressor or vacuum pump

A low cost scroll device and methods of manufacturing the same are described. The scroll device includes, for example, a drive pin hole and bearing bores machined into a scroll of the scroll device from the same side as the involute of the scroll; idler shaft assemblies with no more than one bearing in the orbiting scroll for mechanically coupling the orbiting scroll to the fixed scroll; and an epoxy coating applied using a process that requires assembly of the scroll device only once.

Mesward, Joshua R.↗

Dual drive co-rotating spinning scroll compressor or expander

A dual-drive co-rotating scroll device includes a housing; a first scroll rotatably mounted within the housing via a first cylindrical extension and a first plurality of bearings, and having a first axis of rotation; and a second scroll rotatably mounted within the housing via a second cylindrical extension and a second plurality of bearings, and having a second axis of rotation different than the first axis of rotation. At least one of the first cylindrical extension and the second cylindrical extension may comprise a plurality of permanent magnets and operate as a rotor of a first motor. An Oldham ring may be positioned between the first scroll and the second scroll and configured to maintain a relative angular position between the first scroll and the second scroll.

Wilson, John P. D.↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Building Technologies Office 03.02.02.38 Milestone Report—Compressor Technology Development for Refrigerants with <150 Global Warming Potential

The major purpose of this project is to enable the development of compressors specifically designed for compatibility with low–global warming potential (GWP) refrigerants (with GWP values below 150). These compressors are intended for applications in residential and light commercial air-conditioning and heat pump systems. This report contains an exhaustive review of the existing literature with the intention of discerning the most efficacious methodologies currently in use for compressor modeling. This fundamental stage was designed to foster a comprehensive understanding of the intricate dynamics and mechanics of compressors. As a result, a model (PDSim) was selected to simulate scroll, rotary and linear compressor technologies.

42 ENGINEERING↗

Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration

A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗