Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sealing efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a self-lubricating high-efficiency hybrid seal composed of carbon nanotube-coated metal meshes for CSP turbomachinery (SETO CPS #36333 Final Report)

In turbomachinery, internal leakage flow accounts for up to 3% of the total thermodynamic cycle energy loss. Tradeoff must be made between the sealing efficiency (smaller clearance) and the friction and wear issues for interfering with the shaft (larger clearance). This ORNL-Danfoss joint effort developed a novel hybrid seal composed of carbon nanotube (CNT)-coated metal meshes. The CNT growth process was based on a self-catalyzing chemical vapor deposition and these multiwall CNTs were well aligned with high crystallinity. This hybrid material structure takes advantage of the CNT’s low-friction nature and uses the metal mesh as an extendable backbone. Full-scale experimental seals were designed, fabricated, and optimized for sealing performance and durability. The CNT-coated metal mesh seal demonstrated superior gas sealing efficiency to the baseline labyrinth seal and significantly improved shaft surface protection compared with the state-of-the-art superalloy brush seal on the static rig and full-scale compressor dynamometer tests. The CNT-metal mesh seal is low-cost and scalable and can potentially benefit wide applications, including CSP and other power generation, marine, automotive, and HVAC.

36 MATERIALS SCIENCE↗

Significant slowdown of plasma-optimized surface energy deactivation by vacuum sealing for efficient adhesive bonding

This work proposes an approach to minimize surface energy deactivation of plasma-treated metal and carbon fiber-reinforced polymer (CFRP) surfaces by vacuum sealing. Plasma treatments enhance adhesive wettability on post-treated surfaces for adhesive joints, but the treated surfaces deactivate quickly in air. The surface energy of aluminum alloy AA6061 and carbon fiber-reinforced polymer-polyamide (CFRP-PA66) optimally treated by a blown air plasma instrument returns to the original surface energy within one hour. Vacuum sealing of AA6061 and CFRP-PA66 reduced the surface energy deactivation over 7 days by at least 230 times and 970 times compared to in air. Double Cantilever Beam (DCB) tests performed on adhesively-bonded AA6061/CFRP-PA66 joints showed that the total energy release and energy dissipation before failure of plasma-treated and vacuum-sealed materials was up to 60% more than plasma-treated materials without vacuum sealing and up to 125% more than non-plasma-treated materials.

42 ENGINEERING↗

Loss circulation prevention in geothermal drilling by shape memory polymer

Geothermal formations are naturally fractured with large fracture openings and networks. This can often lead to frequent drilling fluid loss events which is a major contributor to the cost and non-productive time in geothermal drilling. Development of smarter technologies and methods to tackle problem lost circulation is vital for geothermal drilling cost reduction required for geothermal energy to be recognized as a competitive alternative energy source. Mitigation of this problem and other drilling problems such as stuck pipe can minimize overall project cost. In this report, a thermoset shape memory polymer that can be activated by formation natural heat was assessed to seal near wellbore fractures in geothermal wells. The performance of the shape memory polymer (SMP) was evaluated using artificial fractures created in aluminum discs and cylindrical granite cores. Rheology and particle size distribution were considered. A novel testing setup was built for this work, which allows testing of sealing efficiency under dynamic conditions at high temperature. Analysis showed that the SMP has efficiently succeeded in forming a strong plug inside the fractures and stopped fluid loss at high sealing pressure. This smart loss circulation material can expand within the fractures to reduces non-drilling time and strengthen the wellbore in high-temperature drilling operations.

58 GEOSCIENCES↗

Experimental study on rheological and settling properties of shape memory polymer for fracture sealing in geothermal formations

This article studies the rheology and annular flow of a smart lost circulation material (LCM) at 160 °C, using a high-temperature flow loop. The smart LCM is a shape memory polymer (SMP) that activates at high temperatures, and its particle size increases to seal fractures in geothermal formations. SMP was mixed with the base fluid in two different concentrations, 1.0 and 3.0 wt%, to study rheology, wellbore hydraulics, activation process, and settling behavior under different testing conditions. The results of this study showed that the SMP could be activated at high temperatures. An increase of 80–100% in the particle size was observed at 160 °C. The mud samples showed a high shear-thinning behavior at the two concentrations with a Power-law flow index (n) ranging between 0.025 and 0.101. No additional frictional pressure losses were observed when SMP was added to the base fluid. SMP particles showed an excellent suspension at 1.0 wt% while, at 3.0 wt%, a bed was formed at a low flow rate and without pipe rotation. Increasing the drill pipe rotational speed or flow rate effectively removed the bed and homogeneously dispersed the SMP particles, ensuring a better sealing efficiency. SMP particle dispersion in inclined wells was better than in horizontal wells. Moreover, the findings of this study help optimize the lost circulation treatment by considering a wide range of operating parameters that can further be extended to different systems and geometries.

02 PETROLEUM↗

Hermetically sealed porous-wall hollow microspheres enabled by monolithic glass coatings: Potential for thermal insulation applications

Thermal insulation materials are crucial to improve the energy performance of buildings and industrial applications. We report an approach to create hermetically vacuum-sealed silica-based hollow microspheres that can lower the thermal conductivity of closed-cell insulation materials. The wall structure of these hollow microspheres includes a reticulated network of pores or channels that extend through the thickness of the wall. When a thin layer of glass material is applied to the wall exterior, followed by a vacuum-assisted thermal treatment process, the coated microsphere surfaces display a highly dense conformal coverage and near-complete elimination of surface porosity. The sealing efficiency of these microspheres is verified by trapping argon within their cavities as well as through evacuating their hollow cores. Notably, incorporating the evacuated microspheres into a polymer matrix resulted in ~27% enhancement in its thermal insulation performance and no notable loss of performance was observed following three months of exposure to ambient conditions. Thus, we believe that the present study offers a commercially viable strategy that opens the door to applications of such inorganic hollow particles in areas ranging from vacuum-based thermal insulation systems to catalysis, separation technologies, and medical fields.

36 MATERIALS SCIENCE↗

The impact of behavioral and geographic heterogeneity on residential-sector carbon abatement costs

Analyses of monetary and emissions savings from residential efficiency upgrades usually neglect behavioral differences between consumers. Variations in behavior are frequently large: 13% of the U.S. population sets thermostats for cooling at 20 °C (68 °F) or lower and 15% at 25.5 °C (78 °F) or higher. Efficiency analyses should account for behavioral heterogeneity as well as variations in climate and housing characteristics. We model energy and economic savings of efficiency upgrades for U.S. single-family detached houses, accounting for differences in thermostat settings, climate zone, fuel prices, and home characteristics. We consider five efficiency interventions: wall insulation, attic insulation, air sealing, high-efficiency furnaces, and high-efficiency air conditioners. Energy and economic savings vary widely by consumer; the average net present value for wall insulation is $3,020 United States Dollar (USD), but considering heterogeneity, it has a 10th percentile value of -$231 and 90th percentile value of $5,000. Neglecting heterogeneity, technology upgrades can be prioritized from lower to higher carbon abatement costs: air conditioners, wall insulation, furnace, air sealing, and attic insulation. Accounting for heterogeneity reorders this prioritization, and consumer-specific conditions affect mitigation costs such that technologies are mixed in with one another and are no longer arranged one after another. These results indicate that interventions to improve efficiency should consider differences between consumers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Longevity of Hydraulic Power Take-Off Piston Seals in Wave Energy Converters

Wave energy converters (WECs) utilize hydraulic power take-off (PTO) systems. Hydraulic cylinder seals, which are commonly made from thermoplastic or elastomeric polymers, play a vital role in PTO system functionality as they are responsible for containing and isolating high-pressure fluids. However, manufacturers of WECs have identified a significant concern regarding the longevity of hydraulic piston seal wear due to a combination of stressors, such as high pressure, elevated temperature, chemical corrosion, and/or environmental conditions. Seal failure can result in a loss of tightness and fluid leakage, and consequently a reduction in the efficiency of WECs. Seal manufacturers do not typically provide durability data as the materials are not specifically designed for WEC applications, nor do they account for real-world conditions that the materials may be exposed to. Additionally, there is no comparative performance data available between different seal manufacturers, creating uncertainty in hydraulic PTO designs for WECs. This paper reviews the current state of available seal materials for WEC hydraulic PTO systems, seal selection criteria for WEC applications, potential seal degradation mechanisms, and also material properties of the seals, such as density, hardness, tensile strength, and operating temperature. In addition, this paper also examines current evaluation procedures for estimating the durability of WEC PTO seals. Lastly, additional research on estimating the lifespan of piston and rod polymer seals used in hydraulic PTO systems is proposed.

Elen, Muthu↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Air Sealing the Home

Learn how air sealing can improve your home's energy efficiency, comfort, and durability. This fact sheet from Energy Saver includes information on proper ventilation, why to air seal, how to find and seal air leaks, working with contractors to seal your home, and materials to do-it-yourself.

air sealing, air leaks, caulking, weatherstripping↗

Puck and Puck/SAW Loop Seals (Final Report)

Tamper-indicating devices (TIDs), also known as seals, play a crucial role in various sectors including international nuclear safeguards, arms control, domestic security, and commercial products, by ensuring that monitored or high-value items are not accessed undetected. These devices do not block access but alert to unauthorized tampering. With adversaries' capabilities evolving, there's a pressing need for seals to advance in terms of effectiveness (e.g., better tamper indication and unique identification), and new technology can improve the efficiency of installation and verification. Passive loop seals, widely used in international nuclear safeguards to ensure that continuity of knowledge is maintained on declared items, face stringent International Atomic Energy Agency (IAEA) requirements that surpass those met by commercial products. The metal cup seal (Figure 1, left), a staple IAEA seal, is robust but requires significant resources for post-use verification – specifically, the seal’s unique identity can only be verified at IAEA headquarters after removal from facilities. Further, the seal has been in use for decades and seal types should periodically be replaced to counter adversarial efforts for defeating seals. In 2020, the IAEA outlined about 40 requirements for a new passive loop seal, aiming for in-situ verification, minimal external tool use, unique identification (UID), and clear tamper indication. In response, research and development efforts focused on creating a new passive loop seal that meets these criteria and in 2022 the IAEA announced the completion of the Field Verifiable Passive Loop Seal (FVPS) (Figure 1, right). Concurrently to the IAEA’s efforts, Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) designed, developed, and tested two seal versions – Puck and Puck/SAW, with Puck based on the IAEA’s requirements and including a novel visually-obvious tamper response, and Puck/SAW adding additional beneficial capabilities like the ability to receive a unique identifier from a standoff distance and monitoring the wire integrity. Puck/SAW was specifically designed and developed to address sealing applications in dry spent fuel storage facilities, where the number of sealed spent fuel containers results in heavy verification burden and inspector safety issues related to radiation exposure. These efforts are described in this Executive Summary.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

ResStock Measure Documentation: Advanced Air Sealing With Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Air Sealing With Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗