Search NASA⌕ Search

SEARCH · Search NASA

Results for “Seamless integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Seamless integration of commercial Clouds with ATLAS Distributed Computing

The CERN ATLAS Experiment successfully uses a worldwide dis-tributed computing Grid infrastructure to support its physics programme at the Large Hadron Collider (LHC). The Grid workflow system PanDA routinely manages up to 700,000 concurrently running production and analysis jobs to process simulation and detector data. In total more than 500 PB of data are distributed over more than 150 sites in the WLCG and handled by the ATLAS data management system Rucio. To prepare for the ever growing data rate in future LHC runs new developments are underway to embrace industry accepted protocols and technologies, and utilize opportunistic resources in a standard way. This paper reviews how the Google and Amazon Cloud computing ser-vices have been seamlessly integrated as a Grid site within PanDA and Rucio. Performance and brief cost evaluations will be discussed. Such setups could offer advanced Cloud tool-sets and provide added value for analysis facilities that are under discussions for LHC Run-4.

97 MATHEMATICS AND COMPUTING↗

Toward a Seamless Integration of Computing, Experimental, and Observational Science Facilities: A Blueprint to Accelerate Discovery

The Department of Energy, Office of Science operates world-leading facilities for experimental, observational, and computational science. DOE supercomputing facilities will reach performance at the scale of ExaFLOPs in the coming years, enabling new vistas of scale and precision for large scale simulations and data analysis. Experimental scientific facilities are undergoing similar upgrades that will lead to higher data rates and correspondingly larger computational demands, and will increase the need for near-real-time processing and resilient support for more complex workflows. A transformation of science is underway, with workloads at supercomputing facilities increasingly driven by this explosion of data from instruments and experimental facilities, as well as the accelerating use of Artificial Intelligence (AI) as a tool for scientific discovery. A seamless integration of computing, networking, instruments, and experimental facilities is required to support these emerging workloads and open up a new frontier of U.S. leadership in scientific discovery. We propose to accomplish this by providing frictionless access to the ASCR supercomputing facilities. We describe our vision of combining the power of ASCR supercomputers and networking infrastructure into an integrated scalable fabric, available to end user scientists via interfaces that aim to automate and simplify access to high performance computing systems. This will enable unprecedented computational science capabilities for experimental and observational facilities, and will create new opportunities to combine large simulations and modeling with experimental facility data analysis. This blueprint for creating an integrated network of computational and experimental facilities will provide an enriched discovery environment and open doors for new scientific communities to access the DOE’s world-leading computing and networking capabilities.

97 MATHEMATICS AND COMPUTING↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Enabling Seamless Integration of EV Charging Infrastructure with Weak Electric Grids

Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy-duty applications has gained significant interest. Based on ownership and user preferences, light duty and local delivery medium-duty EVs are typically connected to grid distribution networks whereas larger medium duty and heavy-duty EVs are typically connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting them include interoperability, distribution network upgrades, surge in demand charges, power quality issues, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of light-duty EV charging with a focus on DC Fast Charging (DCFC) for weak distribution grids is presented. Three main areas of contributions in this paper include - steady state and dynamic power quality measurements and assessments using real world data, transient assessments of light duty EV integration with weak distribution networks (IEEE 13 node feeder system) under grid-connected and microgrid modes, and formulation of an intelligent charging decision algorithm to enable an impact-minimal charging.

actionable intelligence↗

Enabling Seamless Integration of EV Charging Infrastructure with Weak Electric Grids

Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy duty (LD, MD, and HD) applications has gained significant interest. Based on ownership and user preferences, LD and local delivery MD EVs are typically connected to grid distribution networks whereas larger MD and HD EVs will be connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting it include interoperability, distribution network upgrades, demand charges, power quality, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of LD EV adoption for weak distribution grids is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Achieving Integrated Daylighting and Electric Lighting Systems: Current State of the Art and Needed Research

This paper presents the results of a multi-disciplinary scoping study, the goals of which were to see the seamless integration and application of light in buildings, regardless of source, that is purposely modulated to illuminate surfaces and designed in a way that is comfortable, healthy, pleasing, cost effective, and energy efficient. The scoping study was performed in order to set the stage for transforming the design and realization of lighting systems integration (daylight and electric). This, in turn, will support achieving the the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO) long-term energy savings goals. Holistic lighting systems of the future should include components that are adaptable to change, resilient to disruption, and robust. The system of codes, standards, guidelines, and contracts employed to design and implement lighting systems should be structured to help them to flourish, rather than being barriers to realization. Finally, the research thrusts and mechanisms should be engaged with these goals in mind. While integrated lighting systems may reduce lighting energy use in buildings, a broader web of non-energy impacts affecting occupant’s overall health, comfort, and satisfaction may also guide technology investment goals when the entire lighting systems lifecycle is considered. Daylighting systems are separated from electric lighting systems, and both are characteristically detached from other systems such as safety, security, communications, and information systems. Being disconnected from the inputs and outputs of other building systems precludes the ability to acquire and utilize information about occupation, status of systems, and interior and exterior environmental conditions. The outcome of this separation is that the standard building is not fulfilling the potential for creating dynamic and holistic lighting for building occupants.

Davis, Robert G.↗

Practical Operations of Energy Storage Providing Ancillary Services: From Day-Ahead to Real-Time

As renewable resources are increasingly penetrating power systems, energy storage systems (ESSs) become essential in providing both energy arbitrage and ancillary services. Because of its high flexibility, ESSs have been taken into account in the daily operation of the bulk power system in many places. This paper proposes a general framework in the current electricity market environment to help system operators model the participation of multi-type ESSs and evaluate the performance of both energy arbitrage and reserve provision. We discuss different levels of ESSs' flexibility in providing ancillary services and also consider a deliberate and practical implementation of the modeling. This framework can be seamlessly integrated into the daily market operation without sacrificing computational efficiency. Numerical experiments validate the efficacy of the proposed framework and show that ESSs possess excellent potential in providing ancillary services for the bulk power system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Experimental Covariance Determination for Critical Integral Experiments

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. In general, uncertainty quantification techniques ignore correlations between experiments and shared parts. Experiments, such as the TEX (Thermal/Epithermal eXperiments) campaigns, consist of many shared parts, such as the ‘Jemima’ HEU fuel plates, which create a strong correlation in their uncertainties. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes an intuitive method of determining the covariance for each of the experimental components, providing a correlation for each family of parts across the multiple cases examined within a benchmark. A proof-of-principle study using the TEX-HEU experimental campaign was performed and verified that the correlations can be calculated with information commonly found in the ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. This study showed that the introduction of model and experimental covariances reduces the χ 2 per degree of freedom from 2.203 to 1.179, indicating that the omission causes overly pessimistic bias quantifications. This technique can be seamlessly integrated to current benchmark evaluations as well as reevaluations of legacy benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

TXM-Sandbox : an open-source software for transmission X-ray microscopy data analysis

A transmission X-ray microscope (TXM) can investigate morphological and chemical information of a tens to hundred micrometre-thick specimen on a length scale of tens to hundreds of nanometres. It has broad applications in material sciences and battery research. TXM data processing is composed of multiple steps. A workflow software has been developed that integrates all the tools required for general TXM data processing and visualization. The software is written in Python and has a graphic user interface in Jupyter Notebook . Users have access to the intermediate analysis results within Jupyter Notebook and have options to insert extra data processing steps in addition to those that are integrated in the software. The software seamlessly integrates ImageJ as its primary image viewer, providing rich image visualization and processing routines. As a guide for users, several TXM specific data analysis issues and examples are also presented.

36 MATERIALS SCIENCE↗

PV-BESS DC-Series Integration for Regulated DC Systems

DC-series integration introduces a novel approach to seamlessly integrate a solar photovoltaic (PV) array and a battery energy storage (BES) in series. This system, referred to as the PV-integrated battery energy storage system—dc series (PVBESS-DCS), simplifies integration and enhances power density by leveraging the inherent voltage-source characteristics of batteries and adopting the concept of partial power processing. However, addressing voltage variations of a PV array and a BES under different operational conditions remains a challenge to apply the PVBESS-DCS to a regulated dc system, where the dc-bus voltage is fixed. This article proposes a PVBESS-DCS solution tailored for regulated dc systems. Within this framework, we present a controllable series voltage source compensating for the voltage differences between the PV and BES sources and the dc bus. Thus, the system can perform PV maximum power point tracking and curtailment control while charging and discharging BES and connected to a regulated dc bus. Additionally, we present a single-stage multiport partial power processing dc–dc converter designed for the proposed PVBESS-DCS. It utilizes a triple active bridge dc–dc converter topology. Finally, this article presents operating principles, control strategies, simulation results, and experimental findings of the proposed PVBESS-DCS for regulated dc systems.

25 ENERGY STORAGE↗

Versatile allelic replacement and self-excising integrative vectors for plasmid genome mutation and complementation

ABSTRACT The ability to better understand the function of proteins expressed by bacteria has typically relied upon the development of genetic mutant strains. This approach has been especially challenging for plasmid-encoded genes, as most of the previously described allelic replacement vectors are inefficient for plasmid genome mutation as they either rely on plasmid-derived counterselection toxins or depend on other strategies suchsacB,tetA, andrpsLwhich have been proven to be less efficient for mutant selection. Integrative vectors lack chromophore indicators, thus requiring laborious screening or excision of the vector’s backbone relies on the introduction of a flippase (FLP)-expressing plasmid. The allelic replacement vector, designated here as pDG1, expresses an X-Gal hydrolyzing enzyme (BgaB) that can be used for blue/white screening allowing identification of colonies that integrated and successfully removed the mutagenesis plasmid without a bias for those still carrying it. pDG1 was further improved by including the rhamnose-inducible Tse2 toxin as a potent counterselection system. The efficacy of pDG1 was validated by deleting portions of the plasmid-encoded VirB4/D4 type IV secretion system and aerobactin-synthesizing operons inSalmonella enterica. The integrative vectors, which contain an ΦC31attPsite and genes encoding ΦC31 integrase (int), can seamlessly integrate to target ΦC31attBonSalmonellaplasmids or chromosome. These vectors were improved by insertingbgaBand FLP-encoding genes so that, following integration, most of the vector’s backbone encompassingint,bgaB, and FLP genes can be excised by FLP, without the need for another FLP-expressing vector, creating white colonies carrying a stably integrated target gene. As such, we were able to integrate a 9.3-kb DNA fragment toSalmonellachromosome and flipped out most of the integrated vector in one step, leaving the target fragment in the chromosome. IMPORTANCE In spite of the dissemination of multidrug-resistant plasmids among Gram-negative pathogens, including those carrying virulence genes, vector tools for studying plasmid-born genes are lacking. The allelic replacement vectors can be used to generate plasmid or chromosomal mutations including markless point mutations. This is the first report describing a self-excising integrative vector that can be used as a stable single-copy complementing tool to study medically important pathogens includingin vivostudies without the need for antibiotic selection. Overall, our newly developed vectors can be applied for the assessment of the function of plasmid-encoded genes by specifically creating mutations, moving large operons between plasmids and to/from the chromosome, and complementing phenotypes associated with gene mutation. Furthermore, the vectors express chromophores for the detection of target gene modification or colony isolation, avoiding time-consuming screening procedures.

Microbiology↗

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending Rucio with modern cloud storage support

Rucio is a software framework designed to facilitate scientific collaborations in efficiently organising, managing, and accessing extensive volumes of data through customizable policies. The framework enables data distribution across globally distributed locations and heterogeneous data centres, integrating various storage and network technologies into a unified federated entity. Rucio offers advanced features like distributed data recovery and adaptive replication, and it exhibits high scalability, modularity, and extensibility. Originally developed to meet the requirements of the high-energy physics experiment ATLAS, Rucio has been continuously expanded to support LHC experiments and diverse scientific communities. Recent R&D projects within these communities have evaluated the integration of both private and commercially-provided cloud storage systems, leading to the development of additional functionalities for seamless integration within Rucio. Furthermore, the underlying systems, FTS and GFAL/Davix, have been extended to cater to specific use cases. This contribution focuses on the technical aspects of this work, particularly the challenges encountered in building a generic interface for self-hosted cloud storage, such as MinIO or CEPH S3 Gateway, and established providers like Google Cloud Storage and Amazon Simple Storage Service. Additionally, the integration of decentralised clouds like SEAL is explored. Key aspects, including authentication and authorisation, direct and remote access, throughput and cost estimation, are highlighted, along with shared experiences in daily operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrating Microtransit with Public Transit for Coordinated Multi-Modal Movement of People (Final Technical Report)

This project focused on potential benefits of mobility service providers and transit agencies cooperating to offer fully integrated, seamless multi-modal mobility services for commuters. Specifically, we aimed at developing a first/last mile microtransit and micromobility services tightly integrated with fixed-route transit to achieve the “point-to-point” service capability. Our goal was to provide fixed-route transit customers with two convenient and compelling options for accessing public transit that are also operational efficient.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An epitaxial graphene platform for zero-energy edge state nanoelectronics

Graphene’s original promise to succeed silicon faltered due to pervasive edge disorder in lithographically patterned deposited graphene and the lack of a new electronics paradigm. Here we demonstrate that the annealed edges in conventionally patterned graphene epitaxially grown on a silicon carbide substrate (epigraphene) are stabilized by the substrate and support a protected edge state. The edge state has a mean free path that is greater than 50 microns, 5000 times greater than the bulk states and involves a theoretically unexpected Majorana-like zero-energy non-degenerate quasiparticle that does not produce a Hall voltage. In seamless integrated structures, the edge state forms a zero-energy one-dimensional ballistic network with essentially dissipationless nodes at ribbon–ribbon junctions. Seamless device structures offer a variety of switching possibilities including quantum coherent devices at low temperatures. This makes epigraphene a technologically viable graphene nanoelectronics platform that has the potential to succeed silicon nanoelectronics.

42 ENGINEERING↗