Search NASA⌕ Search

SEARCH · Search NASA

Results for “Selective wetting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Trade study for water and waste management concepts. Task 7: Support special analysis

Cost analyses and tradeoff studies are given for waste management in the Space Station, Lunar Surface Bases, and interplanetary space missions. Crew drinking water requirements are discussed and various systems to recycle water are examined. The systems were evaluated for efficiency and weight savings. The systems considered effective for urine water recovery were vapor compression, flash evaporation, and air evaporation with electrolytic pretreatment. For wash water recovery, the system of multifiltration was selected. A wet oxidation system, which can process many kinds of wastes, is also considered.

Source record↗

Uncertainty of Observation Impact Estimation in an Adjoint Model Investigated with an Observing System Simulation Experiment

Adjoint models are often used to estimate the impact of different observations on short-term forecast skill. A common difficulty with the evaluation of short term forecast quality is the choice of verification fields. The use of self-analysis fields for verification is typical but incestuous, and introduces uncertainty due to biases and errors in the analysis field. In this study, an observing system simulation experiment (OSSE) is used to explore the uncertainty in adjoint model estimations of observation impact. The availability of the true state for verification in the OSSE framework in the form of the Nature Run allows calculation of the observation impact without the uncertainties present in self-analysis verification. These impact estimates are compared to estimates calculated using self-analysis verification. The Global Earth Observing System version 5 (GEOS-5) forecast model with Gridpoint Statistical Interpolation (GSI) is used with the National Aeronautics and Space Administration Global Modeling and Assimilation Office (NASA/GMAO) OSSE capability. The adjoint model includes moist processes, with total wet energy selected as the norm for evaluation of observation impacts. The results show that there are measurable but small discrepancies in the adjoint model estimation of observation impact. In general, observations of temperature and winds tend to have overestimated impacts with self-analysis verification, while observations of humidity and moisture-affected observations tend to have underestimated impacts. The small magnitude of the differences in impact estimates supports the robustness of the adjoint method of estimating observation impacts.

N C Prive↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Fluorescent labels for in situ wet chemistry experiments

We evaluate a wide selection of dyes and suggest a panel that would be the most likely to succeed in a simple flight instrument with a single excitation laser. We also investigate fluorescent semiconductor quantum dots as additions to or replacements for these organic dyes.

in situ wet chemistry experiments quantum dots Mar↗

Selective Plasma Deposition of Fluorocarbon Films on SAMs

A dry plasma process has been demonstrated to be useful for the selective modification of self-assembled monolayers (SAMs) of alkanethiolates. These SAMs are used, during the fabrication of semiconductor electronic devices, as etch masks on gold layers that are destined to be patterned and incorporated into the devices. The selective modification involves the formation of fluorocarbon films that render the SAMs more effective in protecting the masked areas of the gold against etching by a potassium iodide (KI) solution. This modification can be utilized, not only in the fabrication of single electronic devices but also in the fabrication of integrated circuits, microelectromechanical systems, and circuit boards. In the steps that precede the dry plasma process, a silicon mold in the desired pattern is fabricated by standard photolithographic techniques. A stamp is then made by casting polydimethylsiloxane (commonly known as silicone rubber) in the mold. The stamp is coated with an alkanethiol solution, then the stamp is pressed on the gold layer of a device to be fabricated in order to deposit the alkanethiol to form an alkanethiolate SAM in the desired pattern (see figure). Next, the workpiece is exposed to a radio-frequency plasma generated from a mixture of CF4 and H2 gases. After this plasma treatment, the SAM is found to be modified, while the exposed areas of gold remain unchanged. This dry plasma process offers the potential for forming masks superior to those formed in a prior wet etching process. Among the advantages over the wet etching process are greater selectivity, fewer pin holes in the masks, and less nonuniformity of the masks. The fluorocarbon films formed in this way may also be useful as intermediate layers for subsequent fabrication steps and as dielectric layers to be incorporated into finished products.

Crain, Mark M., III↗

Tribology experiment

A two-dimensional concept for Spacelab rack 7 was developed to study the interaction of liquid lubricants and surfaces under static and dynamic conditions in a low-gravity environment fluid wetting and spreading experiments of a journal bearing experiments, and means to accurately measure and record the low-gravity environment during experimentation are planned. The wetting and spreading process of selected commercial lubricants on representative surface are to the observes in a near-zero gravity environment.

Wall, W. A.↗

Assessment of Silver Based Disinfection Technology for CEV and Future US Spacecraft

Silver biocide offers a potential advantage over iodine, the current state-of-the-art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. As such, silver may reduce the overall complexity and mass of future spacecraft potable water systems, particularly those used to support long duration missions. A primary technology gap identified for the use of silver biocide is one of material compatibility. Wetted materials of construction are required to be selected such that silver ion concentrations can be maintained at biocidally effective levels. Preliminary data on silver biocide depletion rates in heritage spacecraft potable water system wetted-materials of construction has been gathered as part of a multi-phase test project aimed at the characterization of silver based biocide technology through: development of preferred materials lists, investigation of silver biocide forms and delivery methods, down-selection of silver biocide technologies, and integrated testing. A 10% - 20% loss in silver ion concentration per day was observed for acid passivated Nitronic 40 tubing with surface area to volume (S/V) ratios of approximately 4.59 cm-1. The Nitronic 40 tubes were tested both with and without biocide pretreatment. Silver biocide depletion was also observed at approximately 0.1% per day for the first 35 days of exposure to acid passivated Inconel 718 coupon, S/V of approximately 0.14 cm-1. Surface analysis by scanning election microscopy (SEM) suggested deposition of silver metal on both test materials. SEM analysis also provided evidence of potential variability in the passivation process for tube configuration of the Nitronic 40 test apparatus. These preliminary results are presented and discussed herein, along with the current project status.

Callahan, Michael R.↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide remains an option of choice for microbial control in spacecraft potable water systems. However, depletion of silver ions by wetted materials readily reduces ionic silver to nonbiocidal levels. This phenomenon occurs via various transport mechanisms at the liquid-solid interfaces between the silver-containing water and adjacent surfaces. Consequently, challenges remain in the design and/or selection of materials that can be used for the wetted system components that will help ensure silver is maintained at biocidal levels. Since silver has been baselined, and/or remains, as a potable water biocide option for several future spacecraft potable water systems, a multitiered approach is being investigated, looking at heritage materials, new processes, and/or alterative materials. This study conducted the application of eleven chemically-resistant coatings onto coupons that were cut out from three types of spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel) to investigate the performance of this material strategy as a barrier against silver depletion. In this investigation, the coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^(-1) and left to soak for predefined time periods. The concentration of the solution in contact with the coated samples was analyzed at various points via inductively coupled plasma mass spectrometry, and the measurements were interpreted as silver retention percentages over time. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination at diminishing silver depletion. The preliminary results demonstrate that some of the selected coatings succeeded at maintaining biocidal silver concentrations far beyond the corresponding base metal in a similar test. The knowledge acquired through this investigation supports the deploying of coatings on plumbing lines for the integration of biocidal silver in the water system architecture of a spacecraft. Nevertheless, further testing must be continued to assess the performance of these coatings on other wetted geometries and any implications of unifying this material strategy with traditional and developmental engineering design processes for spacecraft potable water systems.

water↗

Eutectic superalloys by edge-defined, film-fed growth

The feasibility of producing directionally solidified eutectic alloy composites by edge-defined, film-fed growth (EFG) was carried out. The three eutectic alloys which were investigated were gamma + delta, gamma/gamma prime + delta, and a Co-base TaC alloy containing Cr and Ni. Investigations into the compatibility and wettability of these metals with various carbides, borides, nitrides, and oxides disclosed that compounds with the largest (negative) heats of formation were most stable but poorest wetting. Nitrides and carbides had suitable stability and low contact angles but capillary rise was observed only with carbides. Oxides would not give capillary rise but would probably fulfill the other wetting requirements of EFG. Tantalum carbide was selected for most of the experimental portion of the program based on its exhibiting spontaneous capillary rise and satisfactory slow rate of degradation in the liquid metals. Samples of all three alloys were grown by EFG with the major experimental effort restricted to gamma + delta and gamma/gamma prime + delta alloys. In the standard, uncooled EFG apparatus, the thermal gradient was inferred from the growth speed and was 150 to 200 C/cm. This value may be compared to typical gradients of less than 100 C/cm normally achieved in a standard Bridgman-type apparatus. When a stream of helium was directed against the side of the bar during growth, the gradient was found to improve to about 250 C/cm. In comparison, a theoretical gradient of 700 C/cm should be possible under ideal conditions, without the use of chills. Methods for optimizing the gradient in EFG are discussed, and should allow attainment of close to the theoretical for a particular configuration.

Hurley, G. F.↗

Patterning Techniques for Magnesium Diboride Films for Superconducting Transition Edge Sensor Bolometer Arrays

We present a comparison of several patterning techniques for magnesium diboride films with the goal of making membrane-supported superconducting transition edge sensor bolometer arrays suited for far infrared exploration of outer planets and icy moons. We compare etch properties such as etch rate, selectivity to resist, and edge roughness for wet etching, reactive ion etching, and ion-milling processes.

Travers, D. E.↗

Vibrations of incompressible liquid-plastic tank combinations using a series representation of the liquid

A series representation is presented of the dynamic behavior of incompressible non-viscous liquids contained in partially filled elastic shells of revolution. Using a series in which each term satisfies exactly Laplace's equation, the liquid portion of the problem becomes an integral equation on the wetted wall of the shell. Physical insight required in selecting the terms of the series is such that selection may be readily programed on a computer. Liquid-shell vibration interaction is investigated by modifying an existing shell of revolution vibration program with the series expansion of the liquid pressure loading on the wetted shell wall. Application of the modified program is demonstrated on a hemispherical tank and a realistic scaled model of a launch vehicle tank having a more complex geometry. Comparison of the present analysis with a NASTRAN finite element analysis for a hemispherical tank, and comparison with test results for a launch vehicle tank shows excellent agreement and rapid convergence of the series representation of the liquid to the true solution.

Housner, J. M.↗

Apollo 14 composite casting demonstration

This program assisted in the design and implementation of the composite casting demonstration for the Apollo 14 mission. Both flight and control samples were evaluated. Some conclusions resulting from a comparison of the flight and control samples were: (1) Solidification in neither the flight nor control samples was truly directional. (2) Apparent intermittent contact of the melt with the container in the flight samples led to unusual nucleation and growth structures. (3) There was greater uniformity, on a macro scale, of both pores and structural features in the flight sample; presumably the result of the reduced gravity conditions. (4) It seems quite feasible to produce enhanced dispersions of gases and dense phases in a melt which is solidified in reduced gravity. (5) A two-stage heating/cooling cycle may help directional solidification. (6) Sample materials should be selected from materials in which the dispersant fully wets the matrix material. (7) Experiments should be conducted in two modes: (1) where the melt is in good thermal contact with the container, and (2) where the melt is in a free-float condition.

Source record↗

Modulus, strength and thermal exposure studies of FP-Al2O3/aluminum and FP-Al2O3/magnesium composites

The mechanical properties of FP-Al2O3 fiber reinforced composites prepared by liquid infiltration techniques are improved. A strengthening addition, magnesium, was incorporated with the aluminum-lithium matrix alloy usually selected for these composites because of its good wetting characteristics. This ternary composite, FP-Al2O3/Al-(2-3)Li-(3-5)Mg, showed improved transverse strength compared with FP-Al2O3/Al-(2-3)Li composites. The lower axial strengths found for the FP-Al2O3/Al-(2-3)Li-(3-5)Mg composites were attributed to fabrication related defects. Another technique was the use of Ti/B coated FP-Al2O3 fibers in the composites. This coating is readily wet by molten aluminum and permitted the use of more conventional aluminum alloys in the composites. However, the anticipated improvements in the axial and transverse strengths were not obtained due to poor bonding between the fiber coating and the matrix. A third approach studied to improve the strengths of FP-Al2O3 reinforced composites was the use of magnesium alloys as matrix materials. While these alloys wet fibers satisfactorily, the result indicated that the magnesium alloy composites used offered no axial strength or modulus advantage over FP-Al2O3/Al-(2-3)Li composites.

Bhatt, R. T.↗

Thermoplastic matrix composites - LARC-TPI, polyimidesulfone and their blends

Composites were fabricated from unidirectional unsized AS-4 carbon fiber and two baseline polyimides: benzophenone dianhydride-3,3'-diaminodiphenylsulfone (PISO2) and benzophenone dianhydride-3,3'-diaminobenzophenone (LARC-TPI). In addition, each polymer solution prior to prepregging was doped with various amounts of crystalline LARC-TPI powder to enhance melt flow during press molding. The 2:1, 1:1, and 1:2 ratios of crystalline to amorphous resin, respectively, were studied in the LARC-TPI system and the 1:2 ratio in the PISO2 system. Matrix characterization, prepreg fabrication/characterization and composite fabrication and physical/mechanical properties are described. The latter include three point short beam shear and flexure, dry and wet, as well as fracture toughness properties in selected compositions.

Johnston, Norman J.↗

Thermal and Evolved Gas Analysis of Magnesium Perchlorate: Implications for Perchlorates in Soils at the Mars Phoenix Landing Site

Perchlorate salts were discovered in the soils around the Phoenix landing site on the northern plains of Mars [1]. Perchlorate was detected by an ion selective electrode that is part of the MECA Wet Chemistry Laboratory (WCL). The discovery of a mass 32 fragment (likely 02) by the Thermal and Evolved-Gas Analyzer (TEGA) provided additional confirmation of a strong oxidizer in the soils around the landing site. The purpose of this paper is to evaluate the thermal and evolved gas behavior of perchlorate salts using TEGA-like laboratory testbed instruments. TEGA ovens were fabricated from high purity Ni. Hence, an additional objective of this paper is to determine the effects that Ni might have on the evolved gas behavior of perchlorate salts.

Ming, Douglas W.↗

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗