Search NASA⌕ Search

SEARCH · Search NASA

Results for “Self-sharpening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Microstructurally driven self-sharpening mechanism in beaver incisor enamel facilitates their capacity to fell trees

Beavers ( Castor ) stand out among mammals for their unique capacity to fell trees using their large, ever-growing incisors. This routine consumption of resistant fodder induces prodigious wear in the lower incisors, despite this blunting effect the incisors maintain a remarkably sharp cutting edge. Notably, the enamel edges of their incisors show a highly complex two-part microstructure of which the biomechanical import is unknown. Here, using fracture analysis, nanoindentation, and wear testing on North American beaver ( C. canadensis ) incisors we test the microstructure's possible contribution to maintaining incisal sharpness. Although comparable in hardness, the inner enamel preferentially fails and readily wears at 2.5 times the rate of the outer enamel. The outer microstructure redirects all fractures in parallel, decreasing fracture coalescence. Conversely, the inner microstructure facilitates crack coalescence increasing the wear rate by isolating layers of enamel prisms that readily fragment. Together these two architectures form a microstructurally driven self-sharpening mechanism contained entirely within the thin enamel shell. Here, our results demonstrate that enamel microstructures exposed at the occlusal surface can markedly influence both enamel crest shape and surface texture in wearing dentitions. The methods introduced here open the door to exploring the biomechanical functionality and evolution of enamel microstructures throughout Mammalia.

59 BASIC BIOLOGICAL SCIENCES↗

Shape tuning of large area silicon nanotip arrays through reactive ion etching

Nanostructures formed in silicon form an important class of structures that span a broad spectrum of application areas. Of these, columnar structures of silicon featuring tiplike apexes have their own niche applications. Here, the ability to afford shape tunability for these structures further enhances their application potential. In this paper, we present our findings on the large area fabrication of silicon nanotips defined through microsphere lithography and shape tuned through a combination of different reactive ion etching (RIE) techniques. The self-sharpening mechanism of the tips when using nonplanar etch masks (microspheres) under anisotropic etching conditions is elucidated. We further show that depending on the manner of etching (continuous versus discrete multistep etch), identical anisotropic etching recipes produce vastly different tip morphologies. Hourglass-shaped silicon tips were obtained when silicon was subjected to anisotropic followed by isotropic etching conditions. Sharp silicon tips with tip apex radii on the order of 2 nm have been successfully realized when the RIE shape tuned tips were subjected to a series of oxidative sharpening steps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electrophoresis in space at zero gravity

Early planning for manufacturing operations in space include the use of electrophoresis for purification and separation of biological materials. Greatly simplified electrophoresis apparatus have been flown in the Apollo 14 and 16 missions to test the possibility of stable liquid systems in orbit. Additionally, isoelectric focusing and isotachophoresis are of particular interest as they offer very high resolution and have self-sharpening boundaries. The value of possible space electrophoresis is substantial. For example, present technology permits large fractionation of only a few of blood proteins many fractions, and separated cell populations are needed for research.

Bier, M.↗

Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites

Quality knives are typically fabricated from high-strength steel alloys. Depending on the application, there are different requirements for mechanical and physical properties that cause problems for steel alloys. For example, diver's knives are generally used in salt water, which causes rust in steel knives. Titanium diver's knives are a popular alternative due to their salt water corrosion resistance, but are too soft to maintain a sharp cutting edge. Steel knives are also magnetic, which is undesirable for military applications where the knives are used as a tactical tool for diffusing magnetic mines. Steel is also significantly denser than titanium (8 g/cu cm vs. 4.5 g/cu cm), which results in heavier knives for the same size. Steel is hard and wear-resistant, compared with titanium, and can keep a sharp edge during service. A major drawback of both steel and titanium knives is that they must be ground or machined into the final knife shape from a billet. Since most knives have a mirrored surface and a complex shape, manufacturing them is complex. It would be more desirable if the knife could be cast into a net or near-net shape in a single step. The solution to the deficiencies of titanium, steel, and ceramic knives is to fabricate them using bulk metallic glasses (or composites). These alloys can be cast into net or near-net shaped knives with a combination of properties that exceed both titanium and steel. A commercially viable BMG (bulk metallic glass) or composite knife is one that exhibits one or all of the following properties: It is based on titanium, has a self-sharpening edge, can retain an edge during service, is hard, is non-magnetic, is corrosion-resistant against a variety of corrosive environments, is tough (to allow for prying), can be cast into a net-shape with a mirror finish and a complex shape, has excellent wear resistance, and is low-density. These properties can be achieved in BMG and composites through alloy chemistry and processing. For each desired property for knife fabrication and performance, there is an alloy development strategy that optimizes behavior. Although BMG knives have been demonstrated as far back as 1995, they never found commercial success because they had to be ground (which presented problems because the alloys contained beryllium), they weren't low cost (because they weren't cast to a net-shape), they were brittle (because they were made with a low-quality commercial material), and they had extremely poor corrosion resistance (because corrosion was not well-understood in these materials). Ultimately, these shortcomings prevented the widespread commercialization. In the current work, the inventors have applied more than a decade of research on BMGs from Caltech and JPL to develop a better understanding of how to make BMG knives that exhibit an optimal combination of properties, processing and cost. Alloys have been developed based in titanium (and other metals), that exhibit high toughness, high hardness, excellent corrosion resistance, no ferromagnetism, edge-retaining selfsharpening, and the ability to be cast like a plastic using commercially available casting techniques (currently used by commercial companies such as Liquidmetal Technologies and Visser Precision Casting). The inventors argue that depending on the application (diving, military, tactical, utility, etc.) there is an optimal combination of design and alloy composition. Moreover, with new casting technologies not available at the inception of these materials, net-shaped knives can be cast into complex shapes that require no aftermarket forming, except for sharpening using water-cooled polishing wheel. These combinations of discoveries seek to make low-cost BMG knives commercially viable products that have no equal among metal or ceramic knives. Current work at JPL focuses on net-shape casting of these alloys and testing their mechanical properties versus commercially available knives to demonstrate their benefits.

Hoffman, Douglas C.↗

The Multiphasic Teeth of Chiton Articulatus , an Abrasion‐Resistant and Self‐Sharpening Tool for Hard Algae Collection

Abstract Chiton articulatus is a species of mollusk living in the tropical Pacific intertidal rocky shores of Mexico. This species feeds on solid waste organic sources, including hard crustose algae that grow on rocky substrates, by grazing on them with its radula, a flexible chitinous membrane lined with mineralized major lateral teeth. In this study, the composition, morphology, and resulting mechanics of the mature teeth of this species, which have yet to be examined, are revealed. The results show the presence of multiphasic mature teeth, each consisting of aligned hard magnetite nanoparticles on the leading edge of the tooth underneath which are magnetite lamellae, followed by goethite, lepidocrocite, and eventually hydroxyapatite near the trailing edge. This multiregional structure demonstrates a gradation in hardness as well as different microstructural features integrated with tough interfaces. The combination of these microstructural and phase arrangements results in an abrasion‐resistant tough structure with a self‐sharpening ability. The results of this work will help contribute to developing new bioinspired designs while also helping to understand the evolution and feeding habits of these intriguing invertebrates.

36 MATERIALS SCIENCE↗