Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Greenland Surface Melt Dominated by Solar and Sensible Heating

The Greenland Ice Sheet is the primary source of global Barystatic sea-level rise, and at least half of its recent mass-loss acceleration is caused by surface meltwater runoff. Previous studies on surface melt have examined various thermodynamic and dynamic drivers, yet their contributions are not compared using unified observations. We use decade-long in-situ measurements from automatic weather stations throughout the ablation zone to assess energy components and identify the leading physical processes in this area. Large melt events exceeding 3σ contribute only ~2% to total surface melt since 2007. The day-to-day variability of all melt is dominated by sensible heat exchange (31 ± 7%) and shortwave radiation (28 ± 5%). Sensible and solar heating correlate with the occurrence of dry and fast gravity-driven winds. These katabatic winds increase sensible heating of the surface mainly by enhancing vertical mixing that reduces the temperature inversion. The concomitant low humidity and clear skies yield increased solar heating.

54 ENVIRONMENTAL SCIENCES↗

The Role of Non-Local Effects on Surface Sensible Heat Flux Under Different Types of Thermal Structures Over the Arctic Sea-Ice Surface

The effects of atmospheric thermal structure on the surface energy flux are poorly understood over the Arctic sea-ice surface. Here, we explore the mechanism of sensible heat exchange under different types of thermal structures over the Arctic sea-ice surface by using data collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate expedition. The quadrant analysis indicates that strong surface temperature inversions below 100 m enhance non-local effects on the positive (upward) sensible heat flux ($\overline{w'θ'}$) through entrainment of large eddies from the convective boundary layer aloft. However, strong surface inversions restrict the contributions of large eddies to the negative (downward) $\overline{w'θ'}$ due to intensified surface stability. By inspecting the existing parameterization schemes, we found that the European Center for Medium-Range Weather Forecasts Integrated Forecasting System scheme fails to predict the impacts of non-local processes on the positive $\overline{w'θ'}$, and an adjustment term to correct the bias of parameterized $\overline{w'θ'}$ is proposed.

54 ENVIRONMENTAL SCIENCES↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Influence of Tibetan Plateau sensible heat on pre-monsoon dust burdens over South Asia: Observational and modeling evidence

Tibetan Plateau sensible heating (TPSH) effect is recognized as a key driver of the South Asian climate; however its role in regulating the regional dust burdens over South Asia during the pre-monsoon season remains unclear. Using long-term reanalysis and/or observational dust and TPSH data, we show that the dust optical depth at 550 nm (DOD 550 ) over South Asia is significantly positively correlated with TPSH at the interannual scale. DOD 550 over South Asia increases (decreases) by 20 % (12 %) in the strongest (weakest) TPSH years. The phenomenon of TPSH-dust relationships is reinforced by sensitivity experiments by altering TPSH from global climate models. Further mechanism analysis reveals that TPSH perturbation induces regional circulation anomalies over South Asia, which features a low-tropospheric cyclonic response around the Tibetan Plateau. This cyclonic anomaly strengthens the prevailing northwesterly winds, increasing regional dust emissions and transportation over South Asia. This novel mechanism helps understand the South Asian dust change.

54 ENVIRONMENTAL SCIENCES↗

On the Importance of Precipitation‐Induced Surface Sensible Heat Flux for Diurnal Cycle of Precipitation in the Maritime Continent

Abstract The Maritime Continent (MC) exhibits a pronounced diurnal cycle in precipitation, with many high‐resolution models overestimating the diurnal peak and predicting earlier precipitation over the islands than observed. We hypothesize that part of this model bias comes from ignoring precipitation‐induced surface sensible heat flux ( Q P ). To test this conjecture, we performed simulations with and without Q P for April 2009 and June 2006. The inclusion of Q P reduced the bias in diurnal peak precipitation amplitude by 83% in April 2009 and 23% in June 2006. Similarly, the bias in precipitation peak timing decreased by 26% and 15%, respectively. This bias reduction was even more prominent during periods of heavier rainfall. This improvement in both the amplitude and phase of diurnal precipitation also led to a reduction in bias for total precipitation by ∼10%. These findings suggest that Q P cannot be neglected over the MC, particularly during heavy precipitation.

54 ENVIRONMENTAL SCIENCES↗

Estimation of Surface Sensible Heat Flux due to Precipitation over CONUS and Its Impact on Urban Extreme Precipitation Modeling

The surface sensible heat flux induced by precipitation (Q P ) is a consequence of the temperature difference between the surface and the rain droplets. Despite its seemingly negligible nature, Q P is frequently omitted from both meteorological and climatological models. Nevertheless, it is important to acknowledge the numerous occasions in which the instantaneous values of Q P can be significant, particularly during extreme precipitation events. This study undertakes a comprehensive assessment of Q P across the contiguous United States (CONUS) utilizing high-resolution reanalysis, observational data, and numerical modeling to examine the influence of Q P on precipitation and the surface energy budget. The findings indicate that the spatial distribution of Q P climatology is analogous to that of precipitation, with magnitudes ranging from 2 to 3 W m -2 predominantly over the Midwest and Southeast regions. A seasonal analysis of QP reveals that the highest values occurring during the June–August (JJA) period, averaging 3.18 W m -2 . Peak Q P values of approximately 4 W m -2 are observed during JJA over the Great Plains region. We hypothesize that the Q P during an extreme precipitation event would be nonnegligible and have a significant impact on the local weather. To test this conjecture, we perform high-resolution simulations with and without Q P during an extreme precipitation event over the Chicago Metropolitan Area (CMA). The results show that the Q P may be a dominant factor compared to other components of surface heat flux during the zenith of precipitation hours. Also, Q P has the potential to not only diminish precipitation but also alter and reconfigure the remaining surface energy budget components.

54 ENVIRONMENTAL SCIENCES↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Intercomparison of sensible and latent heat flux measurements from combined eddy covariance, energy balance, and Bowen ratio methods above a grassland prairie

We present a comparison of four different methods of measuring sensible (H) and latent (LE) heat fluxes for a year over a mixed grass prairie ecosystem in the Nebraska SandHills [eddy covariance (EC), energy balance/Bowen ratio (EBBR), residual energy (RES), modified Bowen ratio (MBR) methods]. Additionally, we developed a set of quality control criteria for each method and present a simplification to the traditional EBBR setup. Using EC as reference, all methods yielded similar estimates of yearly H (regression slopes (m) ~ 2% from unity; H EC > H EBBR , H RES , and H MBR ). For yearly LE, EBBR and RES yielded similar estimates with EC (m ~ 2% from unity; LE EC < LE EBBR and LE RES ), while a larger bias was found from MBR (m ~ 8% from unity; LE EC > LE MBR ). At shorter time scales (~ hourly), moderate scatter was found about linear regression fits for H between EBBR and EC (R 2 = 0.81), with smaller scatter between RES and MBR, and EC (R 2 = 0.91). For LE, smaller scatter was also measured between EC, and EBBR and RES (R 2 = 0.89 and 0.87, respectively), with the larger scatter between EC and MBR (R 2 = 0.65). This suggests methods other than EC may be well suited to longer-term applications (≥ yearly), but have larger uncertainty on individual measurements.

54 ENVIRONMENTAL SCIENCES↗

Historical sensible-heat-flux variations key to predicting future hydrologic sensitivity

Under anthropogenic climate change (CC), the global hydrological cycle intensifies at a rate known as hydrologic sensitivity (HS). Global climate models (GCMs) exhibit substantial uncertainty in HS. Past work suggests that another form of HS, derived from internal climate variability (IV), is useful for constraining this uncertainty. However, these two forms of HS are weakly related. Here we show that decomposing HS under both CC and IV, based on the global energy budget, provides insight into the likely range of future HS. We find that sensible heat exchange between the atmosphere and ocean is not accounted for in the atmospheric energy budget under IV, masking the connection between HS under IV and CC. Removing this term, a closer relationship emerges. We use observations in conjunction with this relationship to suggest an upward shift in the likely range of future HS (66% confidence interval: 2.00–2.36 W m -2 K -1

54 ENVIRONMENTAL SCIENCES↗

Modulation of springtime surface sensible heating over the Tibetan Plateau on the interannual variability of East Asian dust cycle

Previous observational evidence and numerical simulations have revealed that the surface sensible heating in spring (March–April–May, MAM) over the Tibetan Plateau (TPSH) can affect the Asian regional hydrological cycle, surface energy balance, and climate through altering atmospheric heat source of the Tibetan Plateau (TP). This study aims to investigate the impacts of MAM TPSH on the interannual variability of East Asian dust cycle by using CAM4-BAM (version 4 of the Community Atmosphere Model coupled to a bulk aerosol model), MERRA-2 (version 2 of the Modern-Era Retrospective analysis for Research and Applications) surface dust concentration, and TPSH measurements. Our simulations show that the surface dust concentrations over the East Asian (EA) dust source region and over the northwestern Pacific (NP) in MAM are significantly positively correlated with TPSH, with regionally averaged correlation coefficients of 0.49 for EA and 0.44 for NP. Similar positive correlations are also shown between the MAM TPSH measurements averaged over the 73 observation sites and the surface dust concentration from MERRA-2. Simulation-based comparisons between strongest and weakest TPSH years reveal that, the MAM surface dust concentration in the strongest TPSH years increases with relative differences of 13.1 % over EA and 36.9 % over NP. These corresponding differences are found in MERRA-2 with 22.9 % and 13.3 % over EA and NP, respectively. Further simulated results show that the processes of whole dust cycles (e.g., dust loading, emission, and transport, as well as dust deposition) are also significantly enhanced during the strongest TPSH years over EA and NP. Through enhancing the TP heat source, stronger TPSH in MAM generates an anticyclonic anomaly in middle and upper troposphere over the TP and over the downstream Pacific region, respectively. These atmospheric circulation anomalies induced by the increased TPSH result in increasing the westerly winds over both EA and NP, which in turn increases dust emissions over the dust source, and dust transport over these two regions, as well as the regional dust cycles. These results suggest that addressing the East Asian dust changes in the future climates requires considering not only increasing greenhouse gas emissions but also the variations of the TP's heat source under global warming.

54 ENVIRONMENTAL SCIENCES↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗