Search NASASearch

SEARCH · Search NASA

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of the Impact of Realistic Sensor Physics and the Integration of Ex-Core Sensors on Reactor Power Synthesis

In the work documented in this report, a weighting function–based core power synthesis method was applied to multiple Monte Carlo N-Particle (MCNP) reactor models, which are informed based on simulated self-powered neutron detector (SPND) responses. The weighting function method used has been coined the point-based iterative (PBI) method. The goal of this application is to assess the impact of considering realistic sensor physics in the generation of the simulated SPND outputs as well as to consider how the synthesis is impacted based on the inclusion of ex-core detectors in the model. The NuScale small modular reactor (SMR) and Westinghouse AP1000 pressurized water reactor (PWR) are the models that served as the testbeds for the assessment of realistic sensor physics; this was achieved by using Geant4 SPND models in comparison with analytical models, such that the effect of electron transport in realistic SPND geometries in the Geant4 model can be understood in terms of synthesis error and convergence time. The comparison was considered for fuel burnup–induced perturbations, for a range of sensor string densities and synthesized power distribution axial fidelities. The Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor MCNP model was used to assess the impact of ex-core sensors; this was done by performing synthesis with and without the ex-core detectors and by quantifying the synthesis error and number of iterations associated with Gaussian-type perturbations in many locations in the core. The TAMU TRIGA model was particularly pertinent for this study because of the interest in future experimental tests with SPNDs in this reactor, as well as the ease of modifying the MCNP model to include ex-core detectors with heterogeneously described response functions. Results from the comparison between the Geant4 and analytical SPND models indicate that similar average and maximum synthesis errors were obtained for burnup-induced perturbations in both the NuScale SMR and the AP1000. This was true for a range of sensor string densities and axial fidelities. However, there were marked differences between both the Geant4 and analytically informed models in terms of the iterations required to converge on the synthesized power distribution. Namely, the Geant4-informed models tended to lead to fewer iterations, except for a few sensor–core configurations that had particularly numerous iterations. Results from the ex-core sensor assessment with the TAMU TRIGA model indicate that the inclusion of ex-core sensors drastically reduces the synthesis error of Gaussian-type perturbations close to the edge of the core, and it slightly reduces synthesis errors for perturbations closer to the center of the core. This was achieved with a minimal increase in computational cost—that is, the number of iterations required for convergence. The errors were identified to be in the same location as the perturbation in the core, indicating that the methodology remains robust for unperturbed regions of the core. A secondary result from this study with the TAMU TRIGA was yielded by analysis of the neutron flux levels in the in-core and ex-core sensor locations of the core; these flux levels indicate that SPNDs could be used as both in-core and ex-core sensors, so long as the emitter material is sensitive to thermal neutrons. The results from these studies provide a quantitative understanding of the importance of considering realistic sensor physics and including ex-core sensors to perform accurate and timely power distribution synthesis of a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Analysis of Temperature Effects on GS-13 Short Period Sensors Utilizing Sandia's Seismic Sensor Temperature Testbed

Sandia National Laboratories has fabricated a Seismic Sensor Temperature Testbed (SSTT) suitable for exposing sensors under test to a range of reasonably stable temperatures while a co-located reference sensor is maintained at room temperature. The testbed has proven sufficiently quiet to allow recording of high-coherence signals from regional earthquakes in the passband of the seismometers, allowing a direct comparison of signals between the sensors under test and the reference sensor.

47 OTHER INSTRUMENTATION

Soil Temperature Sensor Data, 2025, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville, Tennessee: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset includes 16 CSV files documenting soil temperature measurements recorded by HOBO Pendant MX Water Temperature Data Loggers. Data collection for all sites began on January 1, 2025. The end time for each sensor is provided in the End Time_2025.csv file. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville.

Salvador, Christian [ORNL] (ORCID:0000000283287777

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION

SynthEsizing Novel H2 Sensors for Operational Resilience in Pipeline Infrastructure (SENSOR)

A flexible and extensible computational framework acts as a black-box materials discovery engine, capable of screening, predicting, and designing advanced materials with minimal manual intervention was developed. While developed for hydrogen sensing, the approach can be readily adapted to other materials challenges, offering a powerful tool for data-driven materials innovation.

08 HYDROGEN

SynthEsizing Novel H2 Sensors for Operational Resilience in Pipeline Infrastructure (SENSOR) (CRADA Final Report)

Hydrogen (H₂) is gaining attention as a versatile energy carrier with potential applications across industrial processes, power generation, and transportation. However, its practical deployment, particularly in large-scale distribution systems, faces significant infrastructure challenges. Transporting hydrogen through dedicated pipelines or blending it into existing natural gas networks can lead to serious issues, such as leakage due to the small size of hydrogen molecules and material degradation in pipelines through embrittlement. These technical risks raise safety concerns and could limit the integration of hydrogen into current energy infrastructures. Additionally, using hydrogen-enriched gas mixtures in combustion systems like turbines and engines introduces new performance and compatibility challenges that must be resolved before widespread use becomes feasible.

08 HYDROGEN

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES

Assessing the limitations of commercial sensors and models for supporting marine carbon dioxide removal monitoring: a case study

Several unknowns remain surrounding marine Carbon Dioxide Removal (mCDR) monitoring, reporting, and verification (MRV) practices and capabilities. Current in-situ sensor technology is limited (primarily pH and pCO 2 ), requiring calculations and assumptions to estimate changes in carbonate chemistry parameters, including total alkalinity (TA). Considering that cost, energy consumption, and accuracy of commercial sensors can vary by orders of magnitude, understanding how well existing sensors perform in an mCDR context is important for this emerging community. Likewise, documenting sensor limitations and how relatively simple models can optimize sensor deployments will improve MRV efforts and support protocol development. Here we (1) compare performance a variety of commercially available sensors in a blind mesocosm experiment simulating ocean alkalinity enhancement (OAE), and how sensor performance impacted carbonate chemistry estimates; (2) evaluate if sensors can distinguish the OAE signal from natural variability during a small scale OAE field test in Sequim Bay, WA, USA, and (3) use an idealized ocean biogeochemistry model to explore optimal sensor network design based on (1) and (2). Our mesocosm results indicate that correctly constraining pH uncertainty will be critical for accurate TA estimates with current sensor technology compared to the less impactful variation caused by uncertainty in pCO 2 (pH data that are presented throughout are reported on the total scale (pH T ) unless otherwise noted). Our pilot field test demonstrated that sensors were capable of distinguishing mCDR signatures from natural variability under optimal real-world conditions. Idealized modeling simulations of the field test showed that a range of sparse and dense (3 to 100) sensors sampling areas of detectable increases will underestimate the net change in surface pH by at least 35–55%, at both realistic and highly elevated alkalinity input levels. We also highlight the limitations of current sensing technology for MRV, and the importance of ocean biogeochemistry models as critical tools for predicting when and where mCDR signals will be detectable using available sensors. Overall, our findings suggest that commercially available pCO 2 sensors and some pH sensors will form an important backbone for mCDR MRV tasks, though complete MRV characterization will require these data to be used in combination with other tools.

OAE

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL

Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning

Quantifying methane emissions is essential for meeting near-term climate goals and is typically carried out using methane concentrations measured downwind of the source. One major source of methane that is important to observe and promptly remediate is fugitive emissions from oil and gas production sites but installing methane sensors at the thousands of sites within a production basin is expensive. In recent years, relatively inexpensive metal oxide sensors have been used to measure methane concentrations at production sites. Current methods used to calibrate metal oxide sensors have been shown to have significant shortcomings, resulting in limited confidence in methane concentrations generated by these sensors. To address this, we investigate using machine learning (ML) to generate a model that converts metal oxide sensor output to methane mixing ratios. To generate test data, two metal oxide sensors, TGS2600 and TGS2611, were collocated with a trace methane analyzer downwind of controlled methane releases. Over the duration of the measurements, the trace gas analyzer’s average methane mixing ratio was 2.40 ppm with a maximum of 147.6 ppm. The average calculated methane mixing ratios for the TGS2600 and TGS2611 using the ML algorithm were 2.42 ppm and 2.40 ppm, with maximum values of 117.5 ppm and 106.3 ppm, respectively. A comparison of histograms generated using the analyzer and metal oxide sensors mixing ratios shows overlap coefficients of 0.95 and 0.94 for the TGS2600 and TGS2611, respectively. Overall, our results showed there was a good agreement between the ML-derived metal oxide sensors’ mixing ratios and those generated using the more accurate trace gas analyzer. This suggests that the response of lower-cost sensors calibrated using ML could be used to generate mixing ratios with precision and accuracy comparable to higher priced trace methane analyzers. This would improve confidence in low-cost sensors’ response, reduce the cost of sensor deployment, and allow for timely and accurate tracking of methane emissions.

03 NATURAL GAS

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Exceptional Electrical Detection of Trace NO 2 via Mixed Metal MOF-on-MOF Film-Based Sensors

The tunability of metal–organic frameworks (MOFs) makes them exceptional materials for the development of highly selective, low-power sensors for toxic gas detection. Herein, we demonstrate enhanced detection of NO 2 gas by a MOF-based electrical impedance sensor made using a unique mixed metal MOF-on-MOF synthesis. For this work, a combined experimental and computational study was performed using the exemplar Ni x Mg 1–x -MOF-74 to understand the fundamental structure–property relationships behind metal mixing and MOF film synthesis methods on sensor performance. Density functional theory results indicated that the presence of Ni in Mg-MOF-74 increased framework stability and increased the electron density of states at lower energies near the HOMO, as well as enhanced the NO 2 –Mg adsorption interaction. Impedance data of the Ni x Mg 1–x -MOF-74 films with larger Ni contents showed greater impedance change after exposure to 1 ppm of NO 2 gas. Furthermore, when synthesized through either a drop-cast or direct solvothermal film growth approach, the monometallic Ni-based sensors had the best performance. However, the mixed metal Ni x Mg 1–x -MOF-74 sensors synthesized through a MOF-on-MOF approach resulted in the highest impedance change, outperforming all monometallic Ni-based sensors. In particular, the mixed metal Ni-on-Mg-MOF-74 film was the best-performing sensor with an impedance change of 309 upon trace NO 2 exposure. Change in impedance response after NO 2 exposure was improved by 52% compared to the best monometallic Ni-on-Ni-MOF-74 sensor. Structural analysis of the Ni-on-Mg film showed that the first Mg-MOF-74 layer acts as a structural template controlling the structural features of the final film after metal exchange with Ni. This led to improved film quality, evidenced by the greater crystallinity and larger MOF grain sizes, and resulted in enhanced sensor performance which was not achievable through other metal mixing methods. Altogether, this study identifies structure–property relationships and synthetic templating methods that inform MOF-based sensor design, allowing for improved detection of toxic compounds.

36 MATERIALS SCIENCE