Search NASA⌕ Search

SEARCH · Search NASA

Results for “Session detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stronger Source As Reference For Weaker Source In VLBI

Observation of weak astronomical radio source by very-long-baseline interferometry (VLBI) enhanced by using relatively strong astronomical radio source within small angular distance from weak source. Strong source and weak source observed alternately during measurement session. Direct detection of strong source provides reference delays and rates of change of delays used to integrate radio visibilities of weak source. Integrated visibilities added coherently over entire measurement session, using observed phases of strong source as references.

Lestrade, Jean-Francois↗

Semantic Features for Classifying Referring Search Terms

When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

99 GENERAL AND MISCELLANEOUS↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reliability of Maximal Strength Testing in Novice Weightlifters

The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an ICC of greater than or equal to 0.90. Future resistive exercise studies should consider the reliability of specific measures to ensure that changes in strength with training are attributable to training and not learning effects associated with 1RM testing.

Loehr, James A.↗

X/Ka Celestial Frame Improvements: Vision to Reality

In order to extend the International Celestial Reference Frame from its S/X-band (2.3/8.4 GHz) basis to a complementary frame at X/Ka-band (8.4/32 GHz), we began in mid-2005 an ongoing series of X/Ka observations using NASA s Deep Space Network (DSN) radio telescopes. Over the course of 47 sessions, we have detected 351 extra-galactic radio sources covering the full 24 hours of right ascension and declinations down to -45 degrees. Angular source position accuracy is at the part-per-billion level. We developed an error budget which shows that the main errors arise from limited sensitivity, mismodeling of the troposphere, uncalibrated instrumental effects, and the lack of a southern baseline. Recent work has improved sensitivity by improving pointing calibrations and by increasing the data rate four-fold. Troposphere calibration has been demonstrated at the mm-level. Construction of instrumental phase calibrators and new digital baseband filtering electronics began in recent months. We will discuss the expected effect of these improvements on the X/Ka frame.

Jacobs, C. S.↗

Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anomaly Detection in Flight Operational Data Using Deep Learning

In this session, we demonstrate two recently developed deep learning models for anomaly detection in flight operational data by the Data Sciences Group at NASA Ames Research Center. The first model is Convolutional Variational Auto-Encoder (CVAE) [1], which is an unsupervised deep encoder-decoder model, designed specifically for finding anomalies in heterogeneous multivariate time series data. We will demonstrate its application to finding anomalies in streaming data from NASA’s Digital Information Platform’s Fuser source. CVAE identifies data instances that are not representative of expected nominal behavior as anomalous. Since it is an unsupervised approach, the flagged anomalies will need to be reviewed by the subject matter experts (SMEs) for validation and labeling and is designed to assist with vulnerability discovery within Safety Monitoring System programs. The second model is Robust and Explainable Semi-supervised Anomaly Detection (RESAD) model [2], which builds on CVAE to allow learning from both minimally labeled data (previously reviewed by the SMEs) as well as majority unlabeled data. RESAD takes advantage of graph theoretic techniques to propagate the labels from the labeled data to the unlabeled data based on a pre-defined similarity metric and structures the learned feature space from flight time-series so that data of the same class would cluster tightly together. This model characteristic is enabled by training with an augmented loss function and allows learning of a more informative feature space for down-stream tasks such as search and active learning. We demonstrate RESAD using data from the NASA DASHlink project [3].

anomaly detection↗

Radiation Detectors for DHS Applications

Presentation to be presented during the 2021 ANS Virtual Meeting, Radiation Detection for Homeland Security Technical Session, on June 14, 2021 (https://www.ans.org/meetings/am2021/session/view-582/).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Challenges of Using Real-Time Detection Systems: From Data Gathering to Actionable Information [Slides]

This session will discuss challenges and real life examples associated with Real-Time Detection Systems (RTDS) used in exposure assessment strategies. This first presentation will provide an overview of RTDS as used as part of an overall exposure assessment strategy and to document regulatory compliance. Managing OH consequences has been problematic when it comes to actionable information gleaned from sensor data. The judgement of regulatory entities, can be at odds with IH practitioners implementing an exposure strategy that creates exposure profiles and judges workplace exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Emerging contaminants: Presentations at the 2009 Toxicology and Risk Assessment Conference

A session entitled 'Emerging Contaminants' was held in April 2009 in Cincinnati, OH at the 2009 Toxicology and Risk Assessment Conference. The purpose of the session was to share information on both programmatic and technical aspects associated with emerging contaminants. Emerging contaminants are chemicals or materials that are characterized by a perceived or real threat to human health or environment, a lack of published health standards or an evolving standard. A contaminant may also be 'emerging' because of the discovery of a new source, a new pathway to humans, or a new detection method or technology. The session included five speakers representing the Department of Defense (DoD), the Environmental Protection Agency (EPA), and each of the military services. The DoD created the Emerging Contaminant Directorate to proactively address environmental, health, and safety concerns associated with emerging contaminants. This session described the scan-watch-action list process, impact assessment methodology, and integrated risk management concept that DoD has implemented to manage emerging contaminants. EPA presented emerging trends in health risk assessment. Researchers made technical presentations on the status of some emerging contaminates in the assessment process (i.e. manganese, RDX, and naphthalene).

60 APPLIED LIFE SCIENCES↗

Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XXI

This volume contains 12 sessions, 28 papers and 26 presentations on the following topics: Photonic Integrated Circuits and Plasmonic Sensing; Advancs in CBE Signature Modeling and Sensor Algorithms I; Standoff Sensing of CBRNE Hazards I; Standoff Sensing of CBRNE Hazards II; Advances in CBE Signature Modeling and Sensor Algorithms II; Biological Hazard Sensing; Chemical Hazard Sensing; Joint Session with Conferences 11390 and 11416: Spectroscopy for CBRNE Detection and Warning; Radiological and Nuclear Sensing; Explosive Material Sensing; Poster Session.

47 OTHER INSTRUMENTATION↗

A VLA survey of BY Draconis variables

Observations of seven rapidly rotating BY Dra variables, obtained at 6 cm with the D-to-A hybrid array of the VLA on three consecutive days in February, 1986, are reported. The results are presented in tables and graphs (along with data from simple VLA detection observations in 1985 and published optical and X-ray data) and characterized in detail. No strong correlation is found between the radio and optical emission in the one star (BY Dra) detected at more than one session, and the observable microwave emission of the stars is tentatively attributed to flares alone. A weak correlation between the X-ray luminosity and the maximum 6-cm luminosity of dMe stars is inferred, but the evidence is considered insufficient to establish a relationship between surface signs of magnetic activity and nonthermal radio emission.

Caillault, Jean-Pierre↗

The 1991 International Aerospace and Ground Conference on Lightning and Static Electricity, volume 2

The proceedings of the conference are reported. The conference focussed on lightning protection, detection, and forecasting. The conference was divided into 26 sessions based on research in lightning, static electricity, modeling, and mapping. These sessions spanned the spectrum from basic science to engineering, concentrating on lightning prediction and detection and on safety for ground facilities, aircraft, and aerospace vehicles.

Source record↗

Comparison of Orbital Parameters for GEO Debris Predicted by LEGEND and Observed by MODEST: Can Sources of Orbital Debris be Identified?

Since 2002 the National Aeronautics and Space Administration (NASA) has carried out an optical survey of the debris environment in the geosynchronous Earth-orbit (GEO) region with the Michigan Orbital Debris Survey Telescope (MODEST) in Chile. The survey coverage has been similar for 4 of the 5 years allowing us to follow the orbital evolution of Correlated Targets (CTs), both controlled and un-controlled objects, and Un-Correlated Targets (UCTs). Under gravitational perturbations the distributions of uncontrolled objects, both CTs and UCTs, in GEO orbits will evolve in predictable patterns, particularly evident in the inclination and right ascension of the ascending node (RAAN) distributions. There are several clusters (others have used a "cloud" nomenclature) in observed distributions that show evolution from year to year in their inclination and ascending node elements. However, when MODEST is in survey mode (field-of-view approx.1.3deg) it provides only short 5-8 minute orbital arcs which can only be fit under the assumption of a circular orbit approximation (ACO) to determine the orbital parameters. These ACO elements are useful only in a statistical sense as dedicated observing runs would be required to obtain sufficient orbital coverage to determine a set of accurate orbital elements and then to follow their evolution. Identification of the source(s) for these "clusters of UCTs" would be advantageous to the overall definition of the GEO orbital debris environment. This paper will set out to determine if the ACO elements can be used to in a statistical sense to identify the source of the "clustering of UCTs" roughly centered on an inclination of 12deg and a RAAN of 345deg. The breakup of the Titan 3C-4 transtage on February 21, 1992 has been modeled using NASA s LEGEND (LEO-to-GEO Environment Debris) code to generate a GEO debris cloud. Breakup fragments are created based on the NASA Standard Breakup Model (including fragment size, area-to-mass (A/M), and delta-V distributions). Once fragments are created, they are propagated forward in time with a subroutine GEOPROP. Perturbations included in GEOPROP are those due to solar/lunar gravity, radiation pressure, and major geopotential terms. The question to be addressed: are the UCTs detected by MODEST in this inclination/RAAN region related to the Titan 3C-4 breakup? Discussion will include the observational biases in attempting to detect a specific, uncontrolled target during given observing session. These restrictions include: (1) the length of the observing session which is 8 hours or less at any given date or declination; (2) the assumption of ACO elements for detected object when the breakup model predicts debris with non-zero eccentricities; (3) the size and illumination or brightness of the debris predicted by the model and the telescope/sky limiting magnitude.

Barker, Edwin S.↗