Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shielding Benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Shielding Benchmarks Using the Godiva IV Assembly

The Nuclear Criticality Safety Program (NCSP) is developing a shielding benchmark using the Godiva IV assembly as a source. Its present status is reviewed herein. Even eight decades into the nuclear era, substantial work remains to develop a database of shielding benchmarks to support future nuclear development. A nuclear simulation is only as good as its supporting data, inputs, and validation basis. Uncertainty in these areas is addressed using conservatism, which adds margin and, occasionally, cost. In many shielding situations, high accuracy is not necessary because additional material is not particularly expensive. After all, 1–2 cm of lead often reduces the gamma ray dose substantially. However, in certain areas, conservatism can add unnecessary cost. These areas include mobile shielding applications such as casks, ships, microreactors, and spacecraft, where weight and, thus, margin is expensive. Although these characteristics are side benefits for NCSP shielding benchmark development, the main driver is enabling more reliable placement of criticality accident alarm systems (CAASs) in nuclear material facilities, such as those dedicated to the production of advanced reactor fuels. CAAS placement relies on more than accurate data and code validation. It also relies on sufficiently accurate materials specifications, geometry specifications, and a well-defined, alarm-producing baseline accident. All these things require tacit knowledge and understanding of the problem being evaluated. Benchmarks can help ensure this understanding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Availability of Shielding Benchmark Experiment Data in the ICSBEP Handbook

The International Criticality Safety Benchmark Evaluation Projects (ICSBEP) has over two decades of experience under the auspices of the Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) to identify, evaluate, and compile a comprehensive data set of criticality safety benchmark data [1]. The activities of the ICSBEP have led to the continued success of the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) [2]. The contents of the ICSBEP Handbook include benchmark specifications derived from nuclear facilities around the world, which have been utilized to support criticality safety efforts and also integral testing of nuclear data [3]. The 2020 edition of the ICSBEP Handbook will include data from 582 evaluations containing benchmark specifications for 5,053 critical, subcritical, or near-critical configurations. There are seven criticality-alarm-placement/shielding evaluations containing a total of 45 benchmark configurations, and ten fundamental physics evaluations containing a total of 237 measurements relevant to criticality safety applications. The purpose of this paper is to summarize those benchmarks relative to validation needs in shielding applications currently found within the ICSBEP Handbook. The current and future plans of shielding benchmarks with regards to the ICSBEP will also be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of neutron flux spectra of the VVER-1000 mock-up shielding benchmark with Monte Carlo code MCS utilizing mesh-based weight window

The measurements of neutron spectra compiled inside the NEA-1517/82 package from the Shielding Integral Benchmark Archive and Database (SINBAD) are chosen as benchmark cases to validate the variance reduction technique based on weight window in Monte Carlo Code MCS. A full 3D model for fixed source mode calculation with hexagonal lattice source definition is developed to simulate total of 6 points of measurements at the vicinity of the reactor and the reactor pressure vessel region. A code/code comparison against MCNP6 code is first conducted as verification element for the mesh-based weight window capability in MCS. Finally, the validation results are presented against measurements. The verification against MCNP6 code gives good agreement in addition of the insight to the importance of user understanding to determine proper reference point and reference lower weight bound for scaling which is not required in MCS code due to its capability of automatic scaling. The comparison of neutron spectra between MCS and measurements shows good agreement within 3 standard deviations for all of six detector positions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shielding Benchmark Comparison - MCNP6.2

This report documents the calculations performed for a shielding code comparison between various Department of Energy (DOE) sites. These shielding calculations were performed using an experiment drawn from the International Handbook of Evaluated Criticality Safety Benchmark Experiments, published by the Organisation for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA). The benchmark selected for comparison is ALARM-CF-AIR-LAB-001 (“Neutron Fields in the Three-Section Concrete Labyrinth from Cf-252 Source, Benchmark ALARM CF AIR LAB-001”). The Y-12 submission for this code comparison was performed with Monte Carlo N Particle (MCNP) Transport Code System, Version 6.2 and Automated Variance Reduction Generator (ADVANTG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 2 Report

A workable design to perform a CAAS benchmark experiment is detailed herein. Key dimensions, materials, source intensity levels, and detectors are listed in this report. Sensitivity to 21 perturbations was determined to be acceptable. The next step will be for NCSP management to determine whether procurement should occur and if the experiment should proceed. The perturbation study suggests that the room return shield cavity radius and runout should be maintained to within a millimeter, the room return shield should be positioned carefully (perhaps with a laser range finder), and that the detectors should be mounted in a lightweight fixture such as aluminum, so their positioning is assured. Using a 3D scanner or photogrammetry to record part shapes may be beneficial. Further work is also needed to verify source reproducibility.

36 MATERIALS SCIENCE↗

Godiva 4 CAAS Shielding Benchmark: Pre CED-3A Overview [Slides]

Thiis presentation shows the character of an integral experiment. It covers the question why Godiva 4? Additionally, this presentation touches on the IER 498 benchmark quantity, activities facilitated by IER 498, proposed CED-2 test matrix, and what happened during the IER 498’s gap year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Outcomes of WPEC SG47 on "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation"

The Working Party on International Nuclear Data Evaluation Co-operation Subgroup 47 (WPECSG47) entitled "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation" was organised from 2019 and 2022 with the objectives to promote more systematic and wider use of shielding benchmark experiments in nuclear data (ND) and transport code validation and development, to provide feedback on the Shielding Integral Benchmark Archive and Database (SINBAD), and to promote its further development in coordination with the Expert Group on Physics of Reactor Systems (EGPRS). Altogether 9 meetings, the large majority (8) held remotely, were organised during the past 3 years to discuss the experience on the use of SINBAD, evaluation of new benchmarks and improvements to be contributed to the database which was severely neglected and lacking maintenance over the past ← 10+ years. Several proposals for new or updated benchmark evaluation were presented and discussed, such as FNG copper, LLNL pulsed spheres, CIAE iron sphere, KFK 1977 gamma measurements, Rez Fe sphere, ASPIS, ORNL Oxygen broomstick, TIARA and others. Complementing the database with new features was also discussed, for example providing the nuclear data sensitivity profiles more systematically would facilitate and better guide the use of data. Information on the geometry, (radiation source) and materials available in CAD format is expected to allow an easier and less error prone reference for computational model preparation and a potential input to CAD based workflows. Inputs for various transport codes and other benchmark data from participants have been shared via the NEA GitLab which could hopefully in the future evolve and form a bases for critically checked and validated benchmark data. Future development of SINBAD will be monitored by EGPRS and the newly created SINBAD Task Force.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation and Validation of the n+ 63,65 Cu Cross Sections [Slides]

This presentation discusses the objective of the research which is to update n+ 63,65 Cu cross section evaluations with recently measured data to resolve discrepancies in benchmark performance. It also discusses the models used which are the R -matrix analysis and the analysis of angular distribution coefficients. Additionally, the validation methods that were used are discussed, including the Rez shielding benchmark and the ICSBEP criticality benchmarks. In conclusion, he n+ 63,65 Cu cross sections have been updated via R-matrix analysis up to 100 keV. An increased average capture cross section and the adoption of experimentally based Legendre coefficients lead to improved performance in reactivity benchmarks. In the fast region, the adoption of the JENDL-4.0 cross sections above 4.0 MeV improves the performance in shielding benchmarks. Ultimately, the n 63,65 Cu ENDF files will be submitted to ENDF/B-VIII.1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Review of Experimental Data for Validating Computer Codes Used in Shielding Calculations for Spent Fuel Storage and Transportation Systems

This report presents a review of available radiochemical assay data and shielding benchmarks applicable to spent nuclear fuel (SNF) shielding calculations. The relevant information reviewed herein includes the Spent Fuel Composition (SFCOMPO) database, the Shielding Integral Benchmark Archive and Database (SINBAD), the International Handbook of Evaluated Criticality Safety Benchmark Experiments, and published measurements of external dose rates of casks loaded with SNF. The relevant experimental data identified in this report may be used to support verification and validation of computer codes used in SNF cask/transport shielding applications, as well as development of calculation uncertainties. It should be noted that a relatively small subset of the identified experimental data (e.g., criticality alarm experiments) is available in a standard format established by the international community participating in experimental isotopic and shielding data evaluations. An effort of the SFCOMPO Technical Review Group (TRG) is underway to publish first isotopic evaluations of individual assay data using a standard data evaluation format. The SINBAD TRG has recently initiated benchmark evaluations and modernization of the database. Therefore, more relevant information is expected in the future that will enable users to select quality experimental data in depletion code and shielding code validations for SNF applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗