Uncertainty Quantification of Activation Due to Cross Section Data in Neutron Shielding Calculation

Quantification of activation in structure materials around the nuclear reactor through calculation is necessary before start of decommissioning. Then a neutron shielding calculation is carried out to estimate activation of structural materials. Neutron shielding calculation is performed out for spatially large regions around a reactor through deep penetration calculation, calculation result would have significant uncertainty. In order to minimize total amount of structure materials treated as radioactive waste, quantitative estimation on uncertainty of structural activation and its reduction is important. The uncertainties due to calculation arises from that of input data and that of calculation method. Examples of uncertainty of input data is those for nuclear reaction cross section and atom density of the nuclide in the structure. In this study, we focus on the uncertainty of cross section, which would be one of the dominant uncertainties, and try to estimate uncertainty of activation due to cross section data in a neutron shielding calculation. The random sampling method (RS) is used as the uncertainty quantification method. With the RS method, uncertainty estimation can be carried out without modification of computer codes for a neutron shielding calculation. (authors)

36 MATERIALS SCIENCE↗

Comparison Of Hybrid Methods For Global Variance Reduction In Shielding Calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the relative uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed that create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally.

FW-CADIS↗

Comparison of hybrid methods for global variance reduction in shielding calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the statistical uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods - using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations - have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed to create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented in the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally. (authors)

97 MATHEMATICS AND COMPUTING↗

Review of Experimental Data for Validating Computer Codes Used in Shielding Calculations for Spent Fuel Storage and Transportation Systems

This report presents a review of available radiochemical assay data and shielding benchmarks applicable to spent nuclear fuel (SNF) shielding calculations. The relevant information reviewed herein includes the Spent Fuel Composition (SFCOMPO) database, the Shielding Integral Benchmark Archive and Database (SINBAD), the International Handbook of Evaluated Criticality Safety Benchmark Experiments, and published measurements of external dose rates of casks loaded with SNF. The relevant experimental data identified in this report may be used to support verification and validation of computer codes used in SNF cask/transport shielding applications, as well as development of calculation uncertainties. It should be noted that a relatively small subset of the identified experimental data (e.g., criticality alarm experiments) is available in a standard format established by the international community participating in experimental isotopic and shielding data evaluations. An effort of the SFCOMPO Technical Review Group (TRG) is underway to publish first isotopic evaluations of individual assay data using a standard data evaluation format. The SINBAD TRG has recently initiated benchmark evaluations and modernization of the database. Therefore, more relevant information is expected in the future that will enable users to select quality experimental data in depletion code and shielding code validations for SNF applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of SCALE Validations Applicable to Spent Nuclear Fuel Shielding Calculations

This report presents a review of publicly available documents providing validations of SCALE code system capabilities for depletion and shielding calculations. The validation studies primarily used information available in the Spent Fuel Isotopic Composition Database, the Shielding Integral Benchmark Archive and Database, and the International Criticality Safety Benchmark Evaluation Project Handbook. Validation results based on radiochemical assay data and shielding benchmark experiments relevant to spent nuclear fuel shielding applications are summarized in this report. The information summarized in this report supports pressurized water reactor and boiling water reactor spent fuel storage and transportation safety analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

Shielding Calculations for the Hard X-Rays Generated by LCLS Mec Laser System

Linac Coherent Light Source (LCLS) Matter in Extreme Conditions (MEC) Instrument is an X-ray instrument that will be able to create and diagnose High Energy Density (HED) matter. The MEC laser system can generate hard X-ray due to the interaction of the laser and the plasma. This paper summarizes results of the shielding calculations performed to evaluate the radiation hazards induced by this hard X-ray source with Monte Carlo code FLUKA. The dose rates and photon spectra due to this X-ray source are calculated at different locations with different shielding. The influence of the electron temperature on the source terms and the shielding effectiveness was also investigated.

43 PARTICLE ACCELERATORS↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigations about iso-geometric analysis for self-shielding calculations with the subgroup method

The implementation of a self-shielding method for a neutron transport calculation code based on the iso-geometric analysis (IGA) method that can resolve the multi-group neutron transport equation for arbitrary spatial domain, is presented. The self-shielding model based on the subgroup theory is adopted because the subgroup method can be used to perform calculations for any arbitrary geometrical domain which is the main purpose of our IGA code. Some basic theory of the subgroup method is given. A self-shielding calculation based on the PWR fuel pin composed of MOX fuel is presented and compared with a Monte Carlo calculation. The result is that the combination of SN transport theory, IGA and the subgroup method gives correctly shielded cross sections. Validation of the combination of the IGA method and SN neutron transport for subgroup calculations in two steps are presented: the first step is to ascertain the correctness of the IGA solutions compared to a known analytical solution in diffusion theory; the second step is a validation of the IGA solutions compared to a reference calculation in SN transport theory. The relation between the settings for the IGA solver and the accuracy of the results are elucidated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Analytical Shielding Calculations for NSLS-II Linac Lateral Wall with FLUKA Monte-Carlo Program

The bulk shielding for NSLS II accelerator enclosures has been designed to reduce the dose rates to less than 0.5 mrem/h at the occupied regions during normal operation. The lateral wall for Linac enclosure is designed to protect personnel from the transverse radiation. The current Linac lateral wall is composed of 1 m concrete, based on the analytical calculations using Swansons’ thick target approximation [1]. The dose rate calculations with current Linac lateral shielding (general area and penetrations) have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the analytical calculation [1]. The dose rates calculated by SHIELD11 [2] program for limited cases have also been included in this technical note.

36 MATERIALS SCIENCE↗

Comparison of the MCNP6 and FLUKA Codes in Shielding Calculation at ProNova Proton Therapy Facility

The Monte Carlo method is a powerful tool to simulate particle transport in materials, and can be effectively used to design radiation shielding. The purpose of this study is to compare the results from two Monte Carlo codes (MCNP6 and FLUKA ) in shielding design. The calculation was also compared with the measured results from the ProNova Superconducting 360 degrees (SC360) installation at the Knoxville Provision Center for Proton Therapy (PCPT) facility. The SC360 230 MeV continue wave (CW) proton beam is produced by an isochronous cyclotron, the Sumitomo P235. The maximum beam that is extracted into the beamline is 300 nA, which is of 60% of the full current generated in cyclotron. The SC360 facility has an energy selection system for adjusting the proton range, one fixed beam and one gantry room for rotating the beam around the stationary patient. At the entrance to each treatment room beamline, a thickness adjustable Beryllium degrader inserted in the beam path is used to achieve the desirable beam energy. When protons interact with beamline components, the secondary neutrons become the dominant source to determine the radiation shielding. In this study, the dose rate outside the lateral wall of the beamline vault was discussed. The calculations from two Monte Carlo codes were compared and they agreed very well. The dose rates measured by a Wendi-II Neutron Detector agreed within a factor of less than seven compared with the calculation results. The difference may be explained by a variety of factors such as the uncertainty in knowing the exact composition of shielding materials, geometry difference, and the measurement uncertainty due to instrumentation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions: The data of this work allow for the accurate calculation of structural shielding thickness, taking into account the spectral variation with shield thickness, and broad beam conditions, in a realistic geometry. The simplicity of calculations also obviates the need for the use of crude transmission data estimates such as the half and tenth value layer indices. Although this study was primarily designed for brachytherapy, results might also be useful for radiology and nuclear medicine facility design, provided broad beam conditions apply.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-569: Neutron Shielding Calculation Using Analytical and Multi-Monte Carlo Method for Proton Therapy Facility

Purpose: To evaluate the shielding wall design to protect patients, staff and member of the general public for secondary neutron using a simply analytic solution, multi-Monte Carlo code MCNPX, ANISN and FLUKA. Methods: An analytical and multi-Monte Carlo method were calculated for proton facility (Sumitomo Heavy Industry Ltd.) at Samsung Medical Center in Korea. The NCRP-144 analytical evaluation methods, which produced conservative estimates on the dose equivalent values for the shielding, were used for analytical evaluations. Then, the radiation transport was simulated with the multi-Monte Carlo code. The neutron dose at evaluation point is got by the value using the production of the simulation value and the neutron dose coefficient introduced in ICRP-74. Results: The evaluation points of accelerator control room and control room entrance are mainly influenced by the point of the proton beam loss. So the neutron dose equivalent of accelerator control room for evaluation point is 0.651, 1.530, 0.912, 0.943 mSv/yr and the entrance of cyclotron room is 0.465, 0.790, 0.522, 0.453 mSv/yr with calculation by the method of NCRP-144 formalism, ANISN, FLUKA and MCNP, respectively. The most of Result of MCNPX and FLUKA using the complicated geometry showed smaller values than Result of ANISN. Conclusion: The neutron shielding for a proton therapy facility has been evaluated by the analytic model and multi-Monte Carlo methods. We confirmed that the setting of shielding was located in well accessible area to people when the proton facility is operated.

61 RADIATION PROTECTION AND DOSIMETRY↗

SUBGR: A Program to Generate Subgroup Data for the Subgroup Resonance Self-Shielding Calculation

The Subgroup Data Generation (SUBGR) program generates subgroup data, including levels and weights from the resonance self-shielded cross section table as a function of background cross section. Depending on the nuclide and the energy range, these subgroup data can be generated by (a) narrow resonance approximation, (b) pointwise flux calculations for homogeneous media; and (c) pointwise flux calculations for heterogeneous lattice cells. The latter two options are performed by the AMPX module IRFFACTOR. These subgroup data are to be used in the Consortium for Advanced Simulation of Light Water Reactors (CASL) neutronic simulator MPACT, for which the primary resonance self-shielding method is the subgroup method.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NSLS-II beamline scattered gas bremsstrahlung radiation shielding calculation

National Synchrotron Light Source II (NSLS-II) is a new state-of-the-art 3rd generation synchrotron. The NSLS-II facility is shielded up to 3 GeV electron beam energy at 500 mA. When the gas bremsstrahlung (GB) from the storage ring is scattered by the beamline components in the first optical enclosure (FOE), the scattered radiation will pose additional radiation hazard (bypassing primary GB collimators and stops) and challenge the FOE shielding. The scattered GB radiation hazard can be mitigated by supplementary shielding or with an exclusion zone downstream of the FOE.

43 PARTICLE ACCELERATORS↗

The MAVRIC-Shift Sequence in SCALE for Radiation Transport and Shielding Calculations with Automated Variance Reduction and Parallel Computing

A new MAVRIC-Shift sequence has been implemented and tested within the SCALE Code System to provide parallel computing capabilities for radiation transport and shielding analysis with automated variance reduction. This new sequence provides the most widely used capabilities of the MAVRIC sequence and also features the highly scalable Shift Monte Carlo solver, thus enabling faster time-to-solution when run on multiple cores. This report provides a summary of the theory of variance reduction approaches in MAVRIC and the integration of Shift into the MAVRIC sequence of SCALE. Similarities and differences in methodologies between the traditional MAVRIC sequence and the new MAVRIC-Shift sequence are discussed. Validation cases are presented with models of radiation shielding experiments and verification is provided with a series of practical application cases of interest to the US Nuclear Regulatory Commission, the sponsors of this work, including spent nuclear fuel transportation and storage systems.