Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shortwave spectral diffuse downwelling irradiance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

sashevis (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashemfr (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenir (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirlowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevislowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevishisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirhisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sasheniraod

ARM Instrument: Aerosol Optical Depth, derived from atmospheric extinction of solar irradiance

54 ENVIRONMENTAL SCIENCES↗

AWARE Shortwave Spectroradiometer Data

Shortwave spectral irradiance was measured at the West Antarctic Ice Sheet (WAIS) Divide Ice Camp as part of the ARM West Antarctic Radiation Experiment (AWARE). A Panalytical (Inc.) FieldSpec Pro Jr spectroradiometer belonging to Scripps Oceanography recorded downwelling spectral irradiance every minute covering the wavelength interval 350-2200 nm . Spectral resolution is 3 nm (10 nm) for wavelengths shorter (longer) than 1000 nm. Temporal coverage is nearly continuous between 8 December 2015 and 18 January 2016, with a few minutes of data missing during each day for data backup and optical collector hygiene. Spectral irradiances, particularly in the near infrared, are sensitive to cloud optical depth, thermodynamic phase, and effective particle size.

54 ENVIRONMENTAL SCIENCES↗

Radiometer for ACE-ENA

The broadband SPN total, zenith1, and zenith2 downwelling SW irradiances were corrected for tilt up to 10 degrees of tilt (per Long et al., 2010). For tilt greater than 10 degrees these values are set to ""bad"". No tilt correction has been applied to the MFR spectral data.

54 ENVIRONMENTAL SCIENCES↗

icerad (00)

The portable radiation package (PRP) is an instrument suite to collect atmospheric radiation measurements on a moving platform. The instrument suite consists of a precision spectral pyranometer (PSP), precision infrared radiometer (PIR), and continuously rotating shadowband radiometer.

54 ENVIRONMENTAL SCIENCES↗

prptcm (b1)

The portable radiation package (PRP) is an instrument suite to collect atmospheric radiation measurements on a moving platform. The instrument suite consists of a precision spectral pyranometer (PSP), precision infrared radiometer (PIR), and continuously rotating shadowband radiometer.

54 ENVIRONMENTAL SCIENCES↗