Dynamic analysis of rotor blade undergoing rotor power shutdown

A rigid flap-lag blade analysis was developed to simulate a rotor in a wind tunnel undergoing an emergency power shutdown. Results show that for a rotor at a nonzero shaft tilt angle undergoing an emergency power shutdown, the oscillatory lag response is divergent. The mean lag response is large when tested at high collective pitch angles. Reducing the collective pitch during the emergency shutdown reduces the steady lag response. Increasing the rotor shaft tilt angle increases the oscillatory lag response component. The blade lag response obtained by incorporating a nonlinear lag damper model indicates that in this case the equivalent linear viscous damping is lower than originally expected. Simulation results indicate that large oscillatory lag motions can be suppressed if the rotor shaft is returned to the fully vertical position during the emergency power shutdown.

Nguyen, Khanh Quoc↗

Design of automatic startup and shutdown logic for a Brayton-cycle 2- to 15-kilowatt engine

The NASA Lewis Research Center is conducting a closed-Brayton-cycle power conversion system technology program in which a complete power system (engine) has been designed and demonstrated. This report discusses the design of automatic startup and shutdown logic circuits as a modification to the control system presently used in this demonstration engine. This modification was primarily intended to make starting the engine as simple and safe as possible and to allow the engine to be run unattended. In the modified configuration the engine is started by turning the control console power on and pushing the start button after preheating the gas loop. No other operator action is required to effect a complete startup. Shutdown, if one is required, is also effected by a simple stop button. The automatic startup and shutdown of the engine have been successfully and purposefully demonstrated more than 50 times at the Lewis Research Center during 10,000 hours of unattended operation. The net effect of this modification is an engine that can be safely started and stopped by relatively untrained personnel. The approach lends itself directly to remote unattended operation.

Vrancik, J. E.↗

Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system

Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.

Cantoni, D. A.↗

Shutdown characteristics of the Mod-O wind turbine with aileron controls

Horizontal-axis wind turbines utilize partial or full variable blade pitch to regulate rotor speed. The weight and costs of these systems indicated a need for alternate methods of rotor control. Aileron control is an alternative which has potential to meet this need. The NASA Lewis Research Center has been experimentally testing aileron control rotors on the Mod-U wind turbine to determine their power regulation and shutdown characteristics. Experimental and analytical shutdown test results are presented for a 38 percent chord aileron-control rotor. These results indicated that the 38 percent chord ailerons provided overspeed protection over the entire Mod-O operational windspeed range, and had a no-load equilibrium tip speed ratio of 1.9. Thus, the 38 percent chord ailerons had much improved aerodynamic braking capability when compared with the first aileron-control rotor having 20 percent chord ailerons.

Miller, D. R.↗

Combustion stability analysis of preburners in liquid propellant rocket engines during shutdown

A linearized one-dimensional lumped-parameter model capable of predicting the occurrence of the low frequency combustion instability (chugging) experienced during preburner shutdown in the Space Shuttle Main Engines is discussed, and predictions are compared with NASA experimental results. Results from a parametric study of parameters including chamber pressure, fuel and oxygen temperatures, and the effective bulk modulus of the liquid oxidizer suggest that chugging is probably affected by conditions at shutdown through the fuel and oxidizer temperatures. It is suggested that chugging is initiated when the fuel, oxidizer, and helium temperature and flow rates pass into an unstable region, and that chugging may be terminated by decaying pressures.

Lim, Kair-Chuan↗

SSME technology test bed fast shutdown assessment

The fastest practical shutdown sequence for the Technology Test Bed Engine is developed. A sequence is defined and key issues addressed. The conclusion of the study is that a fastest shutdown sequence within the existing SSME design capability is practical and can cut oxidizer consumption by 50 percent. However, the revised sequence would not have prevented any of the prior experienced SSME incidents and would introduce development risk to the program.

Liebman, A.↗

Computer study of emergency shutdowns of a 60-kilowatt reactor Brayton space power system

A digital computer study of emergency shutdowns of a 60-kWe reactor Brayton power system was conducted. Malfunctions considered were (1) loss of reactor coolant flow, (2) loss of Brayton system gas flow, (3)turbine overspeed, and (4) a reactivity insertion error. Loss of reactor coolant flow was the most serious malfunction for the reactor. Methods for moderating the reactor transients due to this malfunction are considered.

Tew, R. C.↗

Transient shutdown analysis of low-temperature thermal diodes

The various thermal diodes available for use in cryogenic systems are described. Two diode types, liquid-trap and liquid-blockage diodes, were considered to be the most attractive, and thermal models were constructed to predict their behavior in the reverse mode. The diodes, which are of similar size and throughput, were also examined experimentally in a parallel test setup under nominally identical conditions. Their characteristics were ascertained in terms of forward-mode and reverse-mode conductances, shutdown times and energies, and recovery to forward-mode operation with ethane as the working fluid in the temperature range 170 K to 220 K. Results show that the liquid-blockage diode is the quicker of the two diodes to shut down from the forward mode (8 min as opposed to 10 min). However, the liquid-blockage diode has a larger reverse-mode conductance which results in a greater overall evaporator temperature rise. The importance of the relative size and heat inputs to the condenser/reservoir configuration of the liquid-blockage diode and the evaporator trap configuration for the liquid-trap diode are demonstrated. Also included are data which show the susceptibility of the diodes to recovery to forward-mode operation. Guidelines for the choice of a particular diode for an actual application are given.

Williams, R. J.↗

An investigation of space shuttle main engine shutdown chugging instability

The Space Shuttle Main Engines experience a low frequency pressure pulsation in both the fuel and oxidizer preburners during shutdown. The pressure pulsations (chugging) occur during the helium purge of oxidizer from the preburner manifolds. Possible causes and triggering mechanisms are considered as details of the chugging process are presented and discussed. A simple chugging model capable of predicting pressure excursion amplitudes and frequencies is proposed and preliminary results presented.

George, P. E., II↗

Hydraulic Shutdown Monitor

Adding switch allows inappropriate control actions to be overridden. Four-pole, double-throw switch added to front panel of controller to disable tracking-error and endpoint-error circuitry yet still retain overload-detection capability. Previously, it was necessary to use adjustable-voltage-level detection equipment connected with cables to hydraulic "dump" or shutdown circuitry in controller.

Fleming, S. T.↗