Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shutter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synchronized Electronic Shutter System (SESS) for Thermal Nondestructive Evaluation

The purpose of this paper is to describe a new method for thermal nondestructive evaluation. This method uses a synchronized electronic shutter system (SESS) to remove the heat lamp's influence on the thermal data during and after flash heating. There are two main concerns when using flash heating. The first concern is during the flash when the photons are reflected back into the camera. This tends to saturate the detectors and potentially introduces unknown and uncorrectable errors when curve fitting the data to a model. To address this, an electronically controlled shutter was placed over the infrared camera lens. Before firing the flash lamps, the shutter is opened to acquire the necessary background data for offset calibration. During flash heating, the shutter is closed to prevent the photons from the high intensity flash from saturating the camera's detectors. The second concern is after the flash heating where the lamps radiate heat after firing. This residual cooling introduces an unwanted transient thermal response into the data. To remove this residual effect, a shutter was placed over the flash lamps to block the infrared heat radiating from the flash head after heating. This helped to remove the transient contribution of the flash. The flash lamp shutters were synchronized electronically with the camera shutter. Results are given comparing the use of the thermal inspection with and without the shutter system.

Zalameda, Joseph N.↗

Fast Laser Shutters With Low Vibratory Disturbances

A prototype vacuum-compatible, fast-acting, long-life shutter unit that generates very little vibratory disturbance during switching is reviewed. This is one of a number of shutters designed to satisfy requirements specific to an experiment, to be performed aboard a spacecraft in flight, in which laser beams must be blocked rapidly and completely, without generating a vibratory disturbance large enough to adversely affect the power and frequency stability of the lasers. Commercial off-the-shelf laboratory shutter units -- typically containing electromagnet-coil-driven mechanisms -- were found not to satisfy the requirements because they are not vacuum-compatible, their actuators engage in uncompensated motions that generate significant vibrations, and their operational lifetimes are too short. Going beyond the initial outerspace application, the present vacuum-compatible, fast-acting, long-life shutter units could also be used in terrestrial settings in which there are requirements for their special characteristics. In designing these shutter units, unbalanced, electromagnetically driven mechanisms were replaced with balanced mechanisms that include commercial piezoelectric bending actuators. In each shutter unit, the piezoelectric bending actuators are configured symmetrically as opposing cantilever beams within a housing that contains integral mounts for lenses that focus a laser beam to a waist at the shutter location. In operation, the laser beam is blocked by titanium blades bonded near the free ends of the piezoelectric benders. The benders are driven by shaped electrical pulses with a maximum voltage differential of less than 60 V. Preliminary measurements indicate that rise and fall times are less than 1 ms.

Brinza, David↗

Piezoelectrically Actuated Shutter for High Vacuum

A piezoelectrically actuated shutter is undergoing development for use in experiments on laser cooling of atoms. The shutter is required to be compatible with ultrahigh vacuum [pressure of 10(exp -9) torr (.1.3 x 10(exp -7) Pa) or less] and to be capable of performing reliably in the vacuum for at least one year. In operation, the shutter would enable the collection and launch of successive samples of cold atoms and would enable the interrogation of the immediately preceding sample while preventing disturbance of the atoms of that sample by light from the collection region. A major constraint is imposed on the design and operation of the shutter by a requirement that it not generate a magnetic field large enough to perturb an atomic clock. An electromagnetically actuated shutter could satisfy all requirements except this one. Hence, it was decided to use piezoelectric instead of electromagnetic actuation. The shutter (see figure) includes two commercial piezoelectrically driven flexure stages that produce a travel of 0.5 mm. Levers mechanically amplify the travel to the required level of 1 cm. Problems that remained to be addressed at the time of reporting the information for this article included lifetime testing and correction of a tendency for shutter blades to bounce open.

Thompson, Robert↗

Some Aspects on the Mechanical Analysis of Micro-Shutters

An array of individually addressable micro-shutters is being designed for spectroscopic applications. Details of the design are presented in a companion paper. The mechanical design of a single shutter element has been completed. This design consists of a shutter blade suspended on a torsion beam manufactured out of single crystal silicon membranes. During operation the shutter blade will be rotated by 90 degrees out of the array plane. Thus, the stability and durability of the beams are crucial for the reliability of the devices. Structures were fabricated using focused ion beam milling in a FEI 620 dual beam machine, and subsequent testing was completed using the same platform. This allowed for short turn around times. We performed torsion and bending experiments to determine key characteristics of the membrane material. Results of measurements on prototype shutters were compared with the predictions of the numerical models. The data from these focused studies were used in conjunction with experiments and numerical models of shutter prototypes to optimize the design. In this work, we present the results of the material studies, and assess the mechanical performance of the resulting design.

Fettig, Rainer K.↗

Iterative Magnetic/Structural Simulation of a MEMS Micro-shutter

A finite element model has been created that simulates the magnetic actuation of a cobalt-iron covered, 0.5micron thick, silicon nitride micro-shutter. The micro-shutter will be used as a transmissible filter in a space-based Multi-object Spectrograph (MOS). A laminated tri-pole permanent magnet is scanned across an array of shutters. The applied magnetic force twists the shutter's torsion hinge and actuates the shutter from the closed, 0 degree position, to the open, 90 degree position. A sequential analysis method was selected. This method uses the interaction between the magnetic and structural fields and is accomplished via the load vectors. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.

Khaskia, Abed M.↗

Low-Light-Shift Cesium Fountain without Mechanical Shutters

A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.

Enzer, Daphna↗

Piezo-Operated Shutter Mechanism Moves 1.5 cm

The figure shows parts of a shutter mechanism designed to satisfy a number of requirements specific to its original intended application as a component of an atomic clock to be flown in outer space. The mechanism may also be suitable for use in laboratory and industrial vacuum systems on Earth for which there are similar requirements. The requirements include the following: a) To alternately close, then open, a 1.5-cm-diameter optical aperture twice per second, with a stroke time of no more than 15 ms, during a total operational lifetime of at least a year; b) To attenuate light by a factor of at least 1012 when in the closed position; c) To generate little or no magnetic field; d) To be capable of withstanding bakeout at a temperature of 200 C to minimize outgassing during subsequent operation in an ultrahigh vacuum; and e) To fit within a diameter of 12 in. (=305 mm) a size limit dictated by the size of an associated magnetic shield. The light-attenuation requirement is satisfied by use of overlapping shutter blades. The closure of the aperture involves, among other things, insertion of a single shutter blade between a pair of shutter blades. The requirement to minimize the magnetic field is satisfied by use of piezoelectric actuators. Because piezoelectric actuators cannot withstand bakeout, they must be mounted outside the vacuum chamber, and, hence, motion must be transmitted from the actuators to the shutter levers via a vacuum-chamber-wall diaphragm.

Glaser, Robert↗

Cryogenic Shutter

Electrically actuated shutter designed to operate many thousands of time at cryogenic temperatures. Open shutter allows light at wavelenghts between 1 and 300 micrometers to enter instrument measures background cosmic radiation. Closed shutter blocks outside radiation from instrument and positions mirror to reflect light from internal source to instrument calibrated. Designed, if power failure occurs, shutter remains in or assumes open position so measurements continue without calibration.

Tyler, Allen↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also thermally connected to a reservoir containing cryogen to further reduce the internal temperature.

Barney, Richard D.↗

The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid

The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.

Schwinger, Scott↗

Synchronized Electronic Shutter System and Method for Thermal Nondestructive Evaluation

The invention is a synchronized electronic shutter system (SESS) and method for same side and through transmission thermal analysis and inspection of a material for finding defects, corrosion, disbond defects, integrity of a weld and determination of paint thickness. The system comprises an infrared detector that acquires background images of the sample. A shutter then covers the detector and lamps rapidly heat the sample above ambient temperature. Shutters cover all lamps at the same time the shutter over the infrared detector is opened. The infrared detector acquires a series of temperature images over time radiated from the sample a s the sample cools down. After collecting a series of temperature images taken by the SESS, a processed image is developed using one of the group comprising time derivative calculation, temperature normalization data reduction routine, thermal diffusivity curve fitting and averaging the series of temperature images.

Joseph N Zalameda↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also termally connected to a reservoir containing the cryogen to further reduce the internal temperature.

Barney, Richard D.↗

Actuation Force Study of Next Generation Micro Shutter Array for More Reliable Actuation

Micro shutter array (MSA) is a programmable optical spatial filtering device fabricated by MEMS technology, which was originally developed for James Webb Space Telescope to enable multi-object spectroscopy. Next Generation Micro Shutter Array (NGMSA) is an effort to improve JWST MSA by eliminating macroscopic actuation magnet and using electrostatic force to achieve simple and reliable instrument that can support NASA’s multiple future missions. We have been fabricating NGMSA with design inherited from JWST, however the legacy design is not friendly for electrostatic actuation because applied force direction on the moving shutter blade is different. We use COMSOL AC/DC module’s electrostatics feature to understand electrostatic force applied on an individual shutter within a range of motion and study new candidate designs. Also, structural mechanics module is used to study torsion bar’s restoration force.

Kim, K.↗

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed shutter

A shutter element is described which is formed by a loop of an electrically conductive ribbon disposed adjacent to the end of a passageway to be shuttered. The shuttered end of the passageway is cut at an acute angle. The two leg portions of the ribbon loop are closely spaced to each other and disposed in a plane parallel to the axis of the passageway. A pulse of high current is switched through the loop to cause the current flowing in opposite directions through adjacent leg portions of the ribbon. This produces a magnetically induced pressure on one of the legs of the ribbon forcing the leg over the end of the passageway in gas tight sealing engagement, and thereby blocking passageway.

Mcclenahan, J. O.↗

Structural Analysis of a Magnetically Actuated Silicon Nitride Micro-Shutter for Space Applications

Finite element models have been created to simulate the electrostatic and electromagnetic actuation of a 0.5gm silicon nitride micro-shutter for use in a spacebased Multi-object Spectrometer (MOS). The micro-shutter uses a torsion hinge to go from the closed, 0 degree, position, to the open, 90 degree position. Stresses in the torsion hinge are determined with a large deformation nonlinear finite element model. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.

Loughlin, James P.↗

Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST)

Summary of Research that was part of the grant: NASA NAG5 - 13405: Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST) Period: May 1 2003-October 31 2005 The above funding resulted in following major achievements related to microshutter system for JWST. 1. The original rectangular pattern of magnetic material was changed into magnetic striped pattern to prevent unnecessary twisting during the actuation. The Original geometry favored magnetic remanence vector being oriented along the longer side of the shutter and thus resulting torque caused out of plane twist. Stripe pattern minimizes the out of plane motion and thus prolongs the life-time of microshutter device. 2. We built a new magnetic system (magnetic rotisserie) allowing an accelerated life test of microshutters at various temperatures. This system identified that shutter are capable to withstand as many as several millions of actuating cycles. Our system also identified fabrication related features, like bowing with temperature, collisions with the frame due to misalignment, delaminating of the light shields due to uncontrolled voltage release and poorly fabricated light shields.

Wasilewski, P.↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗