Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon imager”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Observing cosmic-ray extensive air showers with a silicon imaging detector

Extensive air showers induced from high-energy cosmic rays provide a window into understanding the most energetic phenomena in the universe. We present a new method for observing these showers using the silicon imaging detector Subaru Hyper Suprime-Cam (HSC). This method has the advantage of being able to measure individual secondary particles. When paired with a surface detector array, silicon imaging detectors like Subaru HSC will be useful for studying the properties of extensive air showers in detail. The following report outlines the first results of observing extensive air showers with Subaru HSC. The potential for reconstructing the incident direction of primary cosmic rays is demonstrated and possible interdisciplinary applications are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Atom-resolved imaging with a silicon tip integrated into an on-chip scanning tunneling microscope

Limited throughput is a shortcoming of the Scanning Tunneling Microscope (STM), particularly when used for atomically precise lithography. To address this issue, we have developed an on-chip STM based on Microelectromechanical-Systems (MEMS) technology. The device reported here has one degree of freedom, replacing the Z axis in a conventional STM. The small footprint of the on-chip STM provides a great opportunity to increase STM throughput by incorporating a number of on-chip STMs in an array to realize parallel STM. The tip methodology adopted for the on-chip STM presented here, which is a batch-fabricated Si tip, makes our design conducive to this goal. In this work, we investigate the capability of this on-chip STM with an integrated Si tip for STM imaging. We integrate the on-chip STM into a commercial ultrahigh-vacuum STM system and perform imaging with atomic resolution on par with conventional STMs but at higher scan speeds due to the higher sensitivity of the MEMS actuator relative to a piezotube. The results attest that it is possible to achieve a parallel and high-throughput STM platform, which is a fully batch-fabricated MEMS STM nanopositioner capable of performing atomic-resolution STM imaging.

Instruments & Instrumentation↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

High-field spatial imaging of charge transport in silicon at low temperature

We present direct imaging measurements of charge transport across a 1 cm × 1 cm × 4 mm-thick crystal of high purity silicon (~15 kΩ-cm) at temperatures of 5 K and 500 mK. We use these data to measure lateral diffusion of electrons and holes as a function of the electric field applied along the [111] crystal axis and to verify our low-temperature Monte Carlo software. The range of field strengths in this paper exceed those used in our previous study [R. A. Moffatt et al., Appl. Phys. Lett. 114, 032104 (2019)] by a factor of 10 and now encompass the region in which some recent silicon dark matter detectors operate [R. Agnese et al., Phys. Rev. Lett. 121, 051301 (2018)]. Finally, we also report on a phenomenon of surface charge trapping, which can reduce expected charge collection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging the Acceptor Wave Function Anisotropy in Silicon

We present the first scanning tunneling microscopy (STM) image of hydrogenic acceptor wave functions in silicon. These acceptor states appear as square-ring-like features in STM images and originate from near-surface defects introduced by high-energy bismuth implantation into a silicon (001) wafer. Scanning tunneling spectroscopy confirms the formation of a p-type surface. Effective-mass and tight-binding calculations provide an excellent description of the observed square-ring-like features, confirming their acceptor character and attributing their symmetry to the light- and heavy-hole band degeneracy in silicon. A detailed understanding of the energetic and spatial properties of acceptor wave functions in silicon is essential for engineering large-scale acceptor-based quantum devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Field-resolved space–time characterization of few-cycle structured light pulses

Accompanied by the rapid development of ultrafast laser platforms in recent decades, the spatiotemporal manipulation of ultrashort laser pulses has attracted much attention due to the potential for cutting-edge applications of structured light, including optical tweezers, optical communications, super-resolution imaging, time-resolved spectroscopy in molecules and quantum materials, and strong-field physics. Today, techniques capable of characterizing the full spatial, temporal, and polarization state properties of structured light are strongly desired. Here, we demonstrate a technique, termed 3D TIPTOE, for characterizing structured mid-infrared waveforms, which uses only a two-dimensional silicon-based image sensor as both the detector and the nonlinear medium. By combining the advantages of the sub-cycle time resolution afforded by nonlinear excitation and the spatial resolution inherent to the two-dimensional sensor, the 3D TIPTOE technique allows full characterization of structured electric fields, significantly reducing the complexity of detection compared to other techniques. The validity of the technique is established by measuring both few-cycle Bessel–Gaussian pulses and radially polarized femtosecond vector beams.

Liu, Yangyang (ORCID:0000000335205332)↗

Quantification of silicon carbide grain structure in TRISO fuel by BSE image analysis

The grain structure of the silicon carbide (SiC) layer in tristructural-isotropic (TRISO) fuels has commonly been qualified in fuel specifications based on a qualitative comparison to visual standards to ensure undesirable microstructure are not produced. This approach is inherently dependent on subjective judgement and provides limited data for analysis or comparison. An alternative method to rapidly quantify (i.e., provide a numeric measure of) the grain structure of the SiC layer in TRISO fuels has been developed. This method relies on the identification of silicon carbide grain boundaries based on brightness variation in backscattered electron (BSE) images through the application of automated image processing algorithms. The speed with which the requisite BSE imaging and analysis may be completed enables the practical use of this method on an industrial scale as a part of qualifying TRISO fuel to meet a given specification on silicon carbide grain structure, which is an important parameter for TRISO fuel performance. The method is benchmarked by comparison to prior Electron-Backscattered Diffraction (EBSD) results for TRISO particles from the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗