Search NASA⌕ Search

SEARCH · Search NASA

Results for “Size exclusion chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography

Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.

Jones, W. R., Jr.↗

Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

Ewing, Felecia↗

Nano-fabricated size exclusion chromatograph

This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

nanofluids lab-on-a-chip chromatograph separation↗

Nanofluidic Size-Exclusion Chromatograph

Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

Feldman, Sabrina↗

Use of high pressure liquid chromatography in the study of liquid lubricant oxidation

The general principles of classical liquid chromatography and high-pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analysis of a C-ether liquid lubricant by each technique is illustrated. An analysis by size exclusion chromatography of an ester lubricant, which had been degraded using a micro-oxidation apparatus, is illustrated to show how HPLC can be used in the study of high-temperature lubricant degradation.

Morales, W.↗

Effects of Purification on the Crystallization of Lysozyme

We have additionally purified a commercial lysozyme preparation by cation exchange chromatography, followed by recrystallization. This material is 99.96% pure with respect to macromolecular impurities. At basic pH, the purified lysozyme gave only tetragonal crystals at 20 C. Protein used directly from the bottle, prepared by dialysis against distilled water, or which did not bind to the cation exchange column had considerably altered crystallization behavior. Lysozyme which did not bind to the cation exchange column was subsequently purified by size exclusion chromatography. This material gave predominately bundles of rod-shaped crystals with some small tetragonal crystals at lower pHs. The origin of the bundled rod habit was postulated to be a thermally dependent tetragonal- orthorhombic change in the protein structure. This was subsequently ruled out on the basis of crystallization behavior and growth rate experiments. This suggests that heterogeneous forms of lysozyme may be responsible. These results demonstrate three classes of impurities: (1) small molecules, which may be removed by dialysis; (2) macromolecules, which are removable by chromatographic techniques; and (3) heterogeneous forms of the protein, which can be removed in this case by cation exchange chromatography. Of these, heterogeneous forms of the lysozyme apparently have the greatest affect on its crystallization behavior.

Ewing, Felecia L.↗

Stoichiometry of the large conductance bacterial mechanosensitive channel of E. coli. A biochemical study

MscL, a 15 kDa transmembrane protein, is the only component involved in the formation of a 3 nS channel in the inner membrane of Escherichia coli that opens in response to mechanical or osmotic stress. While previous data had suggested that the functional MscL complex might be a hexamer, a recent crystallographic study of the MscL homologue from M. tuberculosis reveals a pentameric structure. The present work further examines the stoichiometry of the E. coli MscL using a variety of biochemical approaches. Detergent-purified 6His-MscL in solution and MscL in the membrane could be chemically crosslinked with the products displaying ladderlike patterns on SDS gels. Three crosslinking agents (EDC, DMS, and DMA) used at saturating concentrations invariably generated pentamers as the largest product. DSS produced additional bands corresponding to larger complexes although the pentamer band appeared to be the predominant product at high levels of crosslinker. It is not clear whether these extra bands reflect a difference in the crosslinking chemistry of DSS or whether its spacer arm is the longest of those used, or a combination of both facts. For the detergent-solubilized 6His-MscL both sedimentation equilibrium and gel chromatography showed the presence of multiple species. Thus the longer spacer arm could permit both intra- and intercomplex linkages. Nonetheless, the patterns obtained with all agents are consistent with and strongly suggest a pentameric organization for the MscL channel. Expression of MscL as genetically engineered double or triple subunit tandems yields low numbers of functional channels as compared to expressed monomers. The double-tandem assemblies must have an even number of subunits and crosslinking in the membrane confirmed hexamerization. Gel chromatography clearly demonstrated that the channels formed from the double tandems were larger than those formed from WT MscL, consistent with the native channel being pentameric. The observation that both double and triple tandems form channels of normal conductance implies that the pentameric assembly is to some degree independent of the number of subunit repeats in the polypeptide precursor. The channel is thus a pentameric core with the 'extra' subunits left out of the functional complex. From sedimentation equilibrium and size-exclusion chromatography, we also conclude that MscL complexes are not in a dynamic equilibrium with monomers, but are pre-assembled; and thus, their gating properties must result from changes in the conformation of the entire complex induced by the mechanical stress.

NASA Discipline Cell Biology↗

Liquid chromatographic analysis of a formulated ester from a gas-turbine engine test

Size exclusion chromatography (SEC) utilizing mu-Bondagel and mu-Styragel columns with a tetrahydrofuran mobile phase was used to determine the chemical degradation of lubricant samples from a gas-turbine engine test. A MIL-L-27502 candidate, ester-based lubricant was run in a J57-29 engine at a bulk oil temperature of 216 C. In general, the analyses indicated a progressive loss of primary ester, additive depletion, and formation of higher molecular weight material. An oil sample taken at the conclusion of the test showed a reversal of this trend because of large additions of new oil. The high-molecular-weight product from the degraded ester absorbed strongly in the ultraviolet region at 254 nanometers. This would indicate the presence of chromophoric groups. An analysis of a similar ester lubricant from a separate high-temperature bearing test yielded qualitatively similar results.

Jones, W. R., Jr.↗

Synthesis and Properties of Phenylethynyl-Terminated, Star-Branched, Phenylquinoxaline Oligomers

The primary objective of this work was to prepare readily melt and solution processable phenylquinoxaline (PQ) oligomers that could be thermally crosslinked to solvent-resistant resins. Thus, a mixture of 2-(4-hydroxyphenyl)-3-phenyl-6-fluoroquinoxaline and 3-(4-hydroxyphenyl)-2-phenyl-6-fluoroquinoxaline (HPFQ) was used to prepare star-branched PQ oligomers end-capped with 4-fluoro-4-phenylethynylbenzophenone (FPEB). 1,1,1-Tris(4-hydroxyphenyl)ethane (THPE) was used as the branching unit. The oligomer number-average molecular weights (M (bar) (sub n) S) as determined by size exclusion chromatography (SEC) were close to the calculated values of 2922, 4698, 6474, and 13,578 g/mol, and their intrinsic viscosities ranged from 0.16 to 0.57 dl/g (m-cresol at 30 C). The oligomers, which were quite soluble in common organic solvents, had glass transition temperatures (T (sub g) S) that ranged from 181 to 233 C (DSC, DELTA T = 20 C/min). They also underwent an exothermic cure with maxima from 377 to 443 C. The T (sub g) S of the cured oligomers ranged from 259 to 284 C depending on the oligomer M (bar) (sub n) and the curing conditions. The oligomers had low melt viscosities, e.g. an oligomer (SPQ-46) with an M (bar) (sub n) of 4816 g/mol (SEC) had a melt viscosity of 150 Pa s at 348 C. A cured thin film of SPQ-46, which was insoluble in common organic solvents, had a room temperature (RT) tensile strength of 100 MPa, a RT modulus of 2358 MPa, and a RT elongation of 5.9%. A cured sample of SPQ-46 displayed a RT titanium-titanium lap shear tensile strength of 35.2 MPa. SPQ-46/carbon fiber(IM-7) composites, were prepared that displayed a RT flexural strength of 1902 MPa, a RT modulus of 1.38 GPa and a RT open hole compressive strength of 433 MPa.

Ooi, I. H.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-11) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

This paper describes the results of accelerated and operational life tests on bearings for the Moderate Resolution Imaging Spectroradiometer (MODIS). It also describes the post test analysis of the disassembled bearings. Analysis was performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of three test stations were in very good condition after accumulating 68, 144, and 209 million cycles, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-1) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

A Proposed Model for Protein Crystal Nucleation and Growth

How does one take a molecule, strongly asymmetric in both shape and charge distribution, and assemble it into a crystal? We propose a model for the nucleation and crystal growth process for tetragonal lysozyme, based upon fluorescence, light, neutron, and X-ray scattering data, size exclusion chromatography experiments, dialysis kinetics, AFM, and modeling of growth rate data, from this and other laboratories. The first species formed is postulated to be a 'head to side' dimer. Through repeating associations involving the same intermolecular interactions this grows to a 4(sub 3) helix structure, that in turn serves as the basic unit for nucleation and subsequent crystal growth. High salt attenuates surface charges while promoting hydrophobic interactions. Symmetry facilitates subsequent helix-helix self-association. Assembly stability is enhanced when a four helix structure is obtained, with each bound to two neighbors. Only two unique interactions are required. The first are those for helix formation, where the dominant interaction is the intermolecular bridging anion. The second is the anti-parallel side-by-side helix-helix interaction, guided by alternating pairs of symmetry related salt bridges along each side. At this stage all eight unique positions of the P4(sub3)2(sub 1),2(sub 1) unit cell are filled. The process is one of a) attenuating the most strongly interacting groups, such that b) the molecules begin to self-associate in defined patterns, so that c) symmetry is obtained, which d) propagates as a growing crystal. Simple and conceptually obvious in hindsight, this tells much about what we are empirically doing when we crystallize macromolecules. By adjusting the growth parameters we are empirically balancing the intermolecular interactions, preferentially attenuating the dominant strong (for lysozyme the charged groups) while strengthening the lesser strong (hydrophobic) interactions. In the general case for proteins the lack of a singularly defined association pathway may lead to formation of multiple species, i.e., amorphous precipitation. Weak interactions, such as hydrogen bonds, are promiscuous, serving to strengthen rather than define specific interactions. Participation in an interaction sequesters that surface from subsequent interactions, and we expect the strongest bonds to form first. This model, its basis, how it fits into the currently understood osmotic second virial coefficient approach to crystallization, and what it suggests will be discussed.

Pusey, Marc↗

Performance and Analysis of Perfluoropolyalkyl Ether Grease Used on Space Shuttle Actuators--A Case Study

Actuators used on the United States space shuttle fleet are lubricated with unspecified amounts of Braycote 601 (Castrol Braycote) grease consisting of a perfluoropolyalkyl ether (PFPAE) base oil thickened with a polytetrafluoroethylene (PTFE) filler. Each shuttle has four body flap actuators (BFAs) (two on each wing) on a common segmented shaft and four rudder speed brake (RSB) actuators. The actuators were designed to operate for 10 years and 100 flights without periodic relubrication. Visible inspection of two partially disassembled RSB actuators in continuous use for 19 years raised concerns over possible grease degradation due to discoloration of the grease on several places on the surfaces of the gears. Inspection revealed fretting, micropitting, wear and corrosion of the bearings and gears. A small amount of oil dripped from the disassembled actuators. Whereas new grease is beige in appearance, the discolored grease consisted of both grey and reddish colors. Grease samples taken from the actuators together with representative off-the-shelf new and unused grease samples were analyzed by gravimetry for oil content; by inductively coupled plasma spectroscopy (ICP) for metals content; Fourier transform infrared (FTIR) spectroscopy for base oil decomposition; and by size exclusion chromatography (SEC) for determination of the molecular weight distributions of the grease oil. The Braycote 601 grease was stable after 19 years of continuous use in the sealed RSB actuators and was fit for its intended purpose. There were no significant chemical differences between the used grease samples and new and unused samples. Base oil separation was not significant within the sealed actuators. No corrosive effect in the form of iron fluoride was detected. The grey color of grease samples was due to metallic iron. The red color was due to oxidation of the metallic wear particles from the gears and the bearings comprising the actuators.

Morales, Wilfredo↗

Quality assurance procedures for V378A matrix resin

A characterization methodology has been developed on which to base quality assurance procedures for U.S. Polymeric V378A bismaleimide matrix resin. Chemical composition is established by partition reverse phase and size exclusion liquid chromatography. Cure rheology behavior is quantitatively characterized by dynamic viscoelastic analysis using the parallel plate technique. The overall cure process is characterized by differential scanning calorimetry. The sensitivity of the procedures is evaluated by studying the effects of ambient out time on the chemical end behaviorial properties of the resin.

Hamermesh, C. L.↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗