Search NASASearch

SEARCH · Search NASA

Results for “Smart thermostat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Individual Data Sparsity in Smart Thermostat Big Data: Impacts on Modeling Thermostat Use Behavior Dynamics

This study explores the impacts of the sparsity of individual thermostat interaction data on modeling thermostat use behavior dynamics using a dataset of over 100,000 smart thermostats. In developing a data-driven model of Thermal Frustration Theory (TFT), we investigate the challenges and trade-offs in clustering occupant data to enhance predictive accuracy. Our findings reveal that a single, aggregated model fails to capture the diversity of occupant behaviors, resulting in extremely poor prediction performance. Conversely, excessive clustering exacerbates data sparsity, undermining model reliability. By identifying an optimal clustering strategy, we achieve a balance that significantly improves the prediction of manual setpoint changes during demand response (DR) events, enhancing energy management and occupant comfort

Fannon, David

Poster Abstract: Leveraging Large Language Models to Reveal Interpretable Cooling Behaviors from Smart Thermostat Data

Frequent heatwaves and hot summers increasingly challenge occupant comfort, health, and energy grid stability. Addressing these challenges requires a detailed understanding of household cooling behaviors, such as thermostat adjustments and adaptive responses to extreme conditions. Traditional analyses often rely on aggregated numerical metrics that overlook subtle but important household-specific variations. In this study, we introduce a generalizable methodology that integrates large language models (LLMs) with vision capabilities to enable scalable and detailed analysis of residential thermostat data. Using Ecobee's Donate Your Data (DYD) dataset—which provides five-minute records of indoor temperatures, thermostat setpoints, and HVAC runtimes—we focus on two U.S. cities with contrasting summer climates : Austin (TX) and Phoenix (AZ). Because raw time-series data are not well suited for direct LLM analysis, we transform them into visual representations, such as daily indoor temperature trajectories and weekly runtime histograms, to better capture behavioral variations. Leveraging LLMs' visual interpretation, we extract descriptive behavioral features, including temperature preferences, time-of-day cooling orientation, anticipatory versus reactive heatwave responses, and behavioral consistency. These semantic features support unsupervised clustering to identify distinct occupant archetypes at scale, revealing differences—such as morning-centric anticipatory coolers versus households that shift toward warmer setpoints during heatwaves—that can inform demand response, resilience planning, and health-aware interventions. By converting raw numerical data into interpretable behavioral patterns, this methodology enables scalable and practical analysis of occupant behavior, supporting actionable insights for comfort, resilience, and energy management.

Nihar, Kopal

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies: Preprint

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)

Enhancing Smart Home Privacy: A Tutorial on Local Differential Privacy Techniques for Frequency and Mean Estimation

The ubiquity of Internet of Things (IoT) systems has seamlessly integrated into our daily lives, particularly in smart homes where devices continuously monitor and optimize our living environments. These systems significantly contribute to home automation, energy efficiency, and overall comfort. However, this widespread connectivity poses inherent risks linked to the streaming of sensitive household data, necessitating robust privacy preservation mechanisms. This tutorial systematically examines privacy preservation through local differential privacy (LDP), with a particular focus on frequency and mean estimation techniques for smart home applications. Here, we present a comprehensive taxonomy of smart home data formats and provide detailed implementation guidance for event-based and w-event LDP mechanisms. Through practical examples using smart thermostats and HVAC systems, we demonstrate how these techniques can be effectively deployed in real-world scenarios. The tutorial concludes by examining emerging research directions, including adaptive privacy budgets and federated learning approaches, establishing a foundation for privacy-preserving smart home deployments.

Kotevska, Olivera [Oak Ridge National Laboratory (

Master Services Agreement - Flexible Feeder/Distribution System Support: Cooperative Research and Development (Final Report)

PGE will engage NREL on a broad range of projects related to the integration of distributed energy resources (DERs) into the utility's operations. This portfolio of work could include projects focused on DER adoption models, advanced distribution management system (ADMS) and distributed energy management system (DERMS) design, DER dispatch strategy development, and DER valuation framework development. Additional topics could include long-term energy planning, renewable energy, energy efficiency and demand-side management. As well as technology evaluations and design guidance for building retrofits and new construction projects, energy and energy infrastructure planning, policies, and markets (and their analysis), energy storage, energy security and resilience (including energy system-related cybersecurity), transportation and mobility, technology integration analysis. Additionally, other assistance as requested by PGE consistent with NREL’s expertise.

24 POWER TRANSMISSION AND DISTRIBUTION

Virtual Power Plants and Distributed Energy Resource Management Systems

Virtual Power Plants (VPPs) are aggregations of DERs that can balance electrical loads and provide utility-scale and utility-grade grid services like a traditional power plant. This presentation covers VPP definition, State-of-the-Art, Grid Architectures, Example VPP studies, VPP Standards, and VPP Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ResStock Measure Documentation: HVAC Load Flexibility

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "HVAC Load Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

electric load forecasting

Resident Tolerance to Transitional Temperature Deviation in Smart Communities

Choosing the right HVAC system or the right algorithm of implementing demand response may create significant energy and environmental gains while maintaining resident comfort. But these questions are closely related to the concept of user comfort, which in turn requires a reasonable fit between user preferences and temperature setpoints. While setting the temperature right is a well-researched question, systems in transition from one setpoint to another are currently not thoroughly addressed in research. But how tolerant the residents really are if a system spends a large share of time outside of the comfort setpoint. This study gives some early insights on how the deviation of temperature from the setpoint affect perceived resident comfort. We use two weeks of data for a smart neighborhood located in Atlanta, GA. We find that the system spends 20% - 50% of time deviating from the setpoint by more than 1℉. However, we do not find that increasing deviations cause resident complaints or increasing overrides.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION