Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

TU-AB-202-03: Prediction of PET Transfer Uncertainty by DIR Error Estimating Software, AUTODIRECT

Purpose: Deformable image registration (DIR) is a powerful tool, but DIR errors can adversely affect its clinical applications. To estimate voxel-specific DIR uncertainty, a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), has been developed and validated. This work tests the ability of this software to predict uncertainty for the transfer of standard uptake values (SUV) from positron-emission tomography (PET) with DIR. Methods: Virtual phantoms are used for this study. Each phantom has a planning computed tomography (CT) image and a diagnostic PET-CT image set. A deformation was digitally applied to the diagnostic CT to create the planning CT image and establish a known deformation between the images. One lung and three rectum patient datasets were employed to create the virtual phantoms. Both of these sites have difficult deformation scenarios associated with them, which can affect DIR accuracy (lung tissue sliding and changes in rectal filling). The virtual phantoms were created to simulate these scenarios by introducing discontinuities in the deformation field at the lung rectum border. The DIR algorithm from Plastimatch software was applied to these phantoms. The SUV mapping errors from the DIR were then compared to that predicted by AUTODIRECT. Results: The SUV error distributions closely followed the AUTODIRECT predicted error distribution for the 4 test cases. The minimum and maximum PET SUVs were produced from AUTODIRECT at 95% confidence interval before applying gradient-based SUV segmentation for each of these volumes. Notably, 93.5% of the target volume warped by the true deformation was included within the AUTODIRECT-predicted maximum SUV volume after the segmentation, while 78.9% of the target volume was within the target volume warped by Plastimatch. Conclusion: The AUTODIRECT framework is able to predict PET transfer uncertainty caused by DIR, which enables an understanding of the associated target volume uncertainty.

60 APPLIED LIFE SCIENCES↗

Analyzing a Five-Year Failure Record of a Leadership-Class Supercomputer

Extreme-scale computing systems are required to solve some of the grand challenges in science and technology. From astrophysics to molecular biology, supercomputers are an essential tool to accelerate scientific discovery. However, large computing systems are prone to failures due to their complexity. It is crucial to develop an understanding of how these systems fail to design reliable supercomputing platforms for the future. This paper examines a five-year failure and workload record of a leadership-class supercomputer. To the best of our knowledge, five years represents the vast majority of the lifespan of a supercomputer. This is the first time such analysis is performed on a top 10 modern supercomputer. We performed a failure categorization and found out that: i) most errors are GPU-related, with roughly 37% of them being double-bit errors on the cards; ii) failures are not evenly spread across the physical machine, with room temperature presumably playing a major role; and iii) software errors of the system bring down several nodes concurrently. Our failure rate analysis unveils that: i) the system consistently degrades, being at least twice as reliable at the beginning, compared to the end of the period; ii) Weibull distribution closely fits the mean-time-between-failure data; and iii) hardware and software errors show a markedly different pattern. Finally, we correlated failure and workload records to reveal that: i) failure and workload records are weakly correlated, except for certain types of failures when segmented by the hours of the day; ii) several categories of failures make jobs crash within the first minutes of execution; and iii) a significant fraction of failed jobs exhaust the requested time with a disregard of when the failure occurred during execution.

Rojas, Elvis↗

Common Cause Failure Mitigation Experience on Digital I and C System in NPP

CCF is failures of redundant or separate structures, systems, or components due to a shared root cause. The CCF includes those are resulted from severe environments, design errors, calibration and maintenance errors, and consequential failures. In addition, digital I and C systems can be vulnerable to CCF caused by software errors or software developed logic, which could defeat the redundancy achieved by the hardware architecture. Therefore, diversity and defense in-depth (D3) has become an important issue to overcome the CCF of the safety I and C system. The U.S. NRC has established regulatory guidance addressing a method for assessing D3 provided by the safety I and C system architecture at a NPP. This method enables determination of whether vulnerabilities to CCF have been adequately addressed. The guidance is included in BTP 7-19 and Chapter 7 of NUREG-0800. The regulatory guidance provides a methodology for designing diversity. APR1400 establishes the mitigating strategies that consider the characteristics of digital I and C system that contribute to the potential for CCF. The diversity strategies consist of a combination of diversity attributes and associated criteria to address potential CCF vulnerabilities in digital safety I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reading Error Analysis (REA) Software Version 1

This is training presentation for REA (Reading Error Analysis) software. REA is designed for analyzing UGT scope reading errors and for developing reading points optimization algorithms.

97 MATHEMATICS AND COMPUTING↗

Effects of Electrical Stimulation on hiPSC-CM Responses to Classic Ion Channel Blockers

Abstract Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great potential for personalized cardiac safety prediction, particularly for that of drug-induced proarrhythmia. However, hiPSC-CMs fire spontaneously and the variable beat rates of cardiomyocytes can be a confounding factor that interferes with data interpretation. Controlling beat rates with pacing may reduce batch and assay variations, enable evaluation of rate-dependent drug effects, and facilitate the comparison of results obtained from hiPSC-CMs with those from adult human cardiomyocytes. As electrical stimulation (E-pacing) of hiPSC-CMs has not been validated with high-throughput assays, herein, we compared the responses of hiPSC-CMs exposed with classic cardiac ion channel blockers under spontaneous beating and E-pacing conditions utilizing microelectrode array technology. We found that compared with spontaneously beating hiPSC-CMs, E-pacing: (1) reduced overall assay variabilities, (2) showed limited changes of field potential duration to pacemaker channel block, (3) revealed reverse rate dependence of multiple ion channel blockers on field potential duration, and (4) eliminated the effects of sodium channel block on depolarization spike amplitude and spike slope due to a software error in acquiring depolarization spike at cardiac pacing mode. Microelectrode array optogenetic pacing and current clamp recordings at various stimulation frequencies demonstrated rate-dependent block of sodium channels in hiPSC-CMs as reported in adult cardiomyocytes. In conclusion, pacing enabled more accurate rate- and concentration-dependent drug effect evaluations. Analyzing responses of hiPSC-CMs under both spontaneously beating and rate-controlled conditions may help better assess the effects of test compounds on cardiac electrophysiology and evaluate the value of the hiPSC-CM model.

Wei, Feng↗

Characterizing the Impact of Soft Errors Affecting Floating-point ALUs using RTL-level Fault Injection

Strategies to detect, correct, or mitigate the impact of soft errors rely on errors-injection experiments. For efficient evaluation, such experiments typically inject errors in software by sampling errors from a candidate distribution. Most often, these strategies randomly select and flip one bit in the output of an instruction. While single-bit flips might constitute a meaningful model for errors affecting hardware, the appropriateness of this model for software-based errors has not been studied. In this paper, we study the manifestation of errors in the output registers due to errors affecting candidate instructions executed by floating point ALUs. We inject single-bit flips into the RTL descriptions of floating point ALUs and analyze the differences between anticipated and observed outputs when executing floating-point addition, subtraction, multiplication, and division. We choose the operands for these instructions randomly and from operands observed in five benchmarks. We observe a rich distribution of errors in the output and analyze their implications for software-based fault-injection campaigns.

Subasi, Omer↗

Optimizing software-directed instruction replication for GPU error detection

Software-only and software-hardware optimizations to reduce the overhead of intra-thread instruction duplication on a GPU or other instruction processor are disclosed. The optimizations trade off error containment for performance and include ISA extensions with limited hardware changes and area costs.

Hari, Siva↗

Mitiq: A software package for error mitigation on noisy quantum computers

We introduce Mitiq, a Python package for error mitigation on noisy quantum computers. Error mitigation techniques can reduce the impact of noise on near-term quantum computers with minimal overhead in quantum resources by relying on a mixture of quantum sampling and classical post-processing techniques. Mitiq is an extensible toolkit of different error mitigation methods, including zero-noise extrapolation, probabilistic error cancellation, and Clifford data regression. The library is designed to be compatible with generic backends and interfaces with different quantum software frameworks. We describe Mitiq using code snippets to demonstrate usage and discuss features and contribution guidelines. We present several examples demonstrating error mitigation on IBM and Rigetti superconducting quantum processors as well as on noisy simulators.

97 MATHEMATICS AND COMPUTING↗

Building the Scientific Basis for Cyber Resilience of Critical Infrastructure

Rigorous methods and models are needed to quantify, measure, and increase the cyber resilience of critical infrastructure. An adversary may exploit vulnerabilities in the vital networks such as industrial control systems (ICS) associated with critical infrastructure (e.g., energy, financial, transportation, security), in order to achieve harmful consequences. In cyber systems, the number of vulnerabilities may be large, the attack surface changes over time, and the problem consists of both technical and non-technical factors (e.g., errors in software and human error). Given this complex and dynamic landscape, strategically mitigating risk is important, where “risk” considers both the probability of an event and the consequences if that event occurs. One way to decrease risk is to address consequences by ensuring that critical infrastructure is resilient. In this context, resilience is characterized by the magnitude and duration of a deviation from targeted performance levels, given a disruption. Increasing resilience decreases the consequences of a successful attack.

97 MATHEMATICS AND COMPUTING↗

System and methods for hardware-software cooperative pipeline error detection

An error reporting system utilizes a parity checker to receive data results from execution of an original instruction and a parity bit for the data. A decoder receives an error correcting code (ECC) for data resulting from execution of a shadow instruction of the original instruction, and data error correction is initiated on the original instruction result on condition of a mismatch between the parity bit and the original instruction result, and the decoder asserting a correctable error in the original instruction result.

97 MATHEMATICS AND COMPUTING↗

Techniques for recovering from errors when executing software applications on parallel processors

In various embodiments, a software program uses hardware features of a parallel processor to checkpoint a context associated with an execution of a software application on the parallel processor. The software program uses a preemption feature of the parallel processor to cause the parallel processor to stop executing instructions in accordance with the context. The software program then causes the parallel processor to collect state data associated with the context. After generating a checkpoint based on the state data, the software program causes the parallel processor to resume executing instructions in accordance with the context.

Hukerikar, Saurabh↗

Automated quantum error mitigation based on probabilistic error reduction

Current quantum computers suffer from a level of noise that prohibits extracting useful results directly from longer computations. The figure of merit in many near-term quantum algorithms is an expectation value measured at the end of the computation, which experiences a bias in the presence of hardware noise. A systematic way to remove such bias is probabilistic error cancellation (PEC). PEC requires a full characterization of the noise and introduces a sampling overhead that increases exponentially with circuit depth, prohibiting high-depth circuits at realistic noise levels. Probabilistic error reduction (PER) is a related quantum error mitigation method that systematically reduces the sampling overhead at the cost of reintroducing bias. In combination with zero-noise extrapolation, PER can yield expectation values with an accuracy comparable to PEC.Noise reduction through PER is broadly applicable to near-term algorithms, and the automated implementation of PER is thus desirable for facilitating its widespread use. To this end, we present an automated quantum error mitigation software framework that includes noise tomography and application of PER to user-specified circuits. We provide a multi-platform Python package that implements a recently developed Pauli noise tomography (PNT) technique for learning a sparse Pauli noise model and exploits a Pauli noise scaling method to carry out PER.We also provide software tools that leverage a previously developed toolchain, employing PyGSTi for gate set tomography and providing a functionality to use the software Mitiq for PER and zero-noise extrapolation to obtain error-mitigated expectation values on a user-defined circuit.

McDonough, Benjamin↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Plutonium Critical Mass Curve Comparison to Mass at Upper Subcritical Limit (USL) Using Whisper

Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the MCNP ® Monte Carlo radiation transport package. Standard approaches to validation rely on the selection of benchmarks based upon expert judgment. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application or set of applications being analyzed. Using these benchmarks, Whisper computes a calculational margin. Whisper attempts to quantify the margin of subcriticality (MOS) from errors in software and uncertainties in nuclear data. The combination of the Whisper-derived calculational margin and MOS comprise the baseline upper subcritical limit (USL), to which an additional margin may be applied by the nuclear criticality safety analyst as appropriate to ensure subcriticality. A series of critical mass curves for plutonium, similar to those found in Figure 31 of LA-10860-MS, have been generated using MCNP6.1.1 and the iterative parameter study software, WORM_Solver. The baseline USL for each of the data points of the curves was then computed using Whisper 1.1. The USL was then used to determine the equivalent mass for plutonium metal-water system. ANSI/ANS-8.1 states that it is acceptable to use handbook data, such as the data directly from the LA-10860-MS, as it is already considered validated (Section 4.3 4) “Use of subcritical limit data provided in ANSI/ANS standards or accepted reference publications does not require further validation.”). This paper attempts to take a novel approach to visualize traditional critical mass curves and allows comparison with the amount of mass for which the k eff is equal to the USL (calculational margin + margin of subcriticality). However, the intent is to plot the critical mass data along with USL, not to suggest that already accepted handbook data should have new and more rigorous requirements for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Domain-Specific Type-Safe APIs for Hierarchical Scientific Data with Modern C++

General-purpose library application programming interfaces (APIs) for self-describing hierarchical scientific data storage, such as the HDF5 and NetCDF libraries, are traditionally of runtime nature. Runtime errors for entry existence and data types are typically caught later in the development process of higher-level application-specific APIs. In this paper, we propose exploiting modern C++ metaprogramming features to add compile-time type-safety to improve the interaction with a well-defined metadata-rich scientific schema in domain-specific hierarchical datasets. We tackle two aspects of common use: (i) direct data access, (ii) flexible “in-memory” index models for efficient search and data processing. The proposed APIs use C++17’s template type auto deduction features, C++11’s enum class for type-safety and C-style preprocessor macros for generative templated code. We showcase the pros and cons of our initial work on the standard NeXus schema used for annotating and storing experimental neutron scattering data at several facilities around the world on top of HDF5. Extendable compile-time type-safe APIs are a desirable feature that could be indexed by any modern integrated development environment (IDE). Hence, such APIs can help ease the learning curve for domain scientists using a less error-prone software interaction to enhance the findability of their data without resorting to a domain-specific language (DSL).

Godoy, William↗

L-TERRA [SWR-15-34]

Lidar (light detection and ranging) instruments are often used in wind energy studies in place of meteorological towers, as they can collect measurements at higher heights than met towers and are more easily moved to different parts of a site. While lidars can accurately measure mean wind speeds, they frequently measure different values of turbulence intensity (TI) than would be measured by a cup anemometer on a tower. Discrepancies in TI values are caused by several factors, including instrument noise and volume averaging. The inability of lidars to accurately measure turbulence is a significant barrier to replacing met towers with lidars in the future. There is currently no accepted standard process for quantifying and removing these errors in lidar TI measurements. The Software is an error reduction algorithm for lidar-measured turbulence. The algorithm is trained using co-located lidar and meteorological tower data. Lidar-measured parameters, such as wind speed, shear, and TI, will be used to predict the difference between the lidar- and tower-measured TI. The algorithm will be disseminated as a set of computer code that can be used by lidar users and manufacturers to correct lidar TI data in real time or in post-processing.

Newman, Jennifer↗