Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid State Transformer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

AC to AC Solid State Transformer with Bidirectional Switches

This report details the work of the 3-year project for the AC-to-AC Solid State Transformer with Bidirectional Switches project devoted to developing and demonstrated a Type I Solid State Transformer. This report details the design, fabrication, and evaluation of both three-phase and single-phase versions of this solid state transformer operating as a single module, modules in parallel, and modules in cascade. Additionally, this report details the fabrication and evaluation of custom Silicon Carbide bidirectional switches to enable this topology with a comparison between monolithically integrated bidirectional switches as well as co-packaged back-to-back unidirectional devices. Finally, results for custom-fabricated Fe 4 N/ferrite laminated toroidal cores for high frequency transformers are present.

42 ENGINEERING↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid-State Transformation of Uranyl Peroxide Materials through High-Level Irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ·9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis was observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He-ion irradiation on NaUT were also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy was done using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. Furthermore, this transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Solid-state transformation of uranyl peroxide materials through high-level irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ∙9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis has been observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He ion irradiation on NaUT was also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. This transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Human Machine Interface and Controls Development for a Medium Voltage Solid State Transformer

The demand for a more capable electric power grid has increased due to greater energy generation and consumption. • Controlling energy flow bidirectionally with new technologies such as solid state transformers can meet this demand, improving power quality, efficiency, and grid security. • A human machine interface was created to control a medium voltage solid state transformer.

Rafferty, Ezekiel↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid-state transformations during laser directed energy deposition of Ti-6Al-4V powder hydride-dehydrided from scrap metals

During laser directed energy deposition (DED-LB), thermal cycling and powder chemical composition produce distinct thermal histories, which vary mechanical properties. Using real-time X-ray diffraction, this study investigates solid-state transformations during DED-LB to understand process-structure-property relationships for angular Ti-6Al-4V powder hydride–dehydrided from scrap metals. Results showed that regions near the molten pool experienced high cooling rates, leading to martensitic transformation from the β phase and increased hardness. Regions farther from the molten pool underwent tempering without solid-state transformation and decreased hardness. These findings support alternative feedstocks for metal additive manufacturing for a circular economy and resilient supply chains.

Additive manufacturing (AM)↗

Applications of Solid-State Transformers for Electric Power Grid HEMP/GMD Resilience

A high-altitude electromagnetic pulse (HEMP) or geomagnetic disturbance (GMD) can disrupt power grids by inducing low-frequency common-mode (CM) currents. When these currents flow through grounded transformers, they can bias the magnetic core, driving it into saturation and reducing performance or damaging equipment. This work presents a solid-state transformer (SST) to replace vulnerable assets and improve grid resilience. The paper reviews half-cycle saturation in conventional transformers, then describes an SST architecture that neutralizes and redirects CM currents during HEMP/GMD events. A prototype SST is built and validated, demonstrating stable CM-disturbance operation and protection of nearby transformers. Finally, large-scale simulations show how coordinated SST deployment mitigates CM disturbances and strengthens overall grid resilience.

four-leg inverter↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗