SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗

Wide Bandgap Solid State Circuit Breakers for AC and DC Microgrids

The objective of the project is to develop a new class of ultrafast, self-powered, programmable, autonomously operated, bidirectional solid state circuit breakers (SSCBs) using wide band gap (WBG) semiconductors with 1000X reduction in response time and 5X reduction in cost in comparison to commercial mechanical circuit breakers. In particular, we have developed two SSCB prototypes of 380VDC/220VAC/20A and 1000VDC/10A using GaN power switches for common distribution-level AC and DC voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Speed Solid State Circuit Breaker

The U.S. Army Research Laboratory, Fort Monmouth, NJ, has developed and is installing two 3.3 MW high speed solid state circuit breakers at the Army's Pulse Power Center. These circuit breakers will interrupt 4160V three phase power mains in no more than 300 microseconds, two orders of magnitude faster than conventional mechanical contact type circuit breakers. These circuit breakers utilize Gate Turnoff Thyristors (GTO's) and are currently utility type devices using air cooling in an air conditioned enclosure. Future refinements include liquid cooling, either water or two phase organic coolant, and more advanced semiconductors. Each of these refinements promises a more compact, more reliable unit.

Podlesak, Thomas F.↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Reliability Assessment of Solid-State Circuit Breakers (CRADA CRD-21-21469, Project 4 Final Report)

Growth in power requirements and the complexity of emerging distribution systems are creating the need for new solid-state products for many applications. The qualification requirements, testing standards and life-cycle management practices of solid-state devices used in protection applications is not established. The project will leverage newly developed accelerated testing capabilities design specifically for protection applications to generate large data sets that will enable advanced digital techniques for data analysis and embedded health monitoring.

14 SOLAR ENERGY↗

Solid-State dc Circuit Breaker

Circuit breaker with no moving parts protects direct-current (dc) loads. Current which circuit breaker opens (trip current) is adjustable and so is time delay before breaker trips. Forward voltage drop rises from 0.6 to 1.2 V as current rises to trip point. Breaker has two terminals, like fuse, therefore replaces fuse in dc circuit. Powered by circuit it protects and reset by either turning off power source or disconnecting load.

Harvey, P.↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Study of feasibility of solid-state electric switch gear for aircraft and spacecraft

The design of a solid-state circuit breaker that can be interconnected to a second breaker to form a transfer switch is presented. The breaker operates on a nominal 270-V dc circuit and controls power to loads of up to 15 A. Automatic overload trip is provided as a function of excess energy measured through the breaker and/or excess current through the breaker. After an overload trip, up to nine preprogrammable attempts to reclose may be tried with programmable delays between each attempt. The breaker or switch is remotely controllable. Test data on performance in the laboratory over temperatures from -45 to 100 C are provided. The feasibility of solid-state switch gear has been established.

Buchanan, E.↗

Ampaire ARPA-e Electric Flight Testbed

A hybrid-electric aircraft flying testbed was developed in this program with the intent to serve as a dedicated, enduring testbed to test and evaluate ARPA-e CIRCUITS Program and other electrified aviation technologies in relevant flight environments. This testbed enabled rapid development cycles of novel and innovative technologies in the electrified aviation space, maturing them from a research lab environment to flying in an aircraft. By providing research groups with the means to test their transformative technologies in a real-world, aircraft environment, the path to validating the safety and reliability of their technologies for future commercial opportunities was greatly accelerated. Three core technologies were integrated and tested: an inverter/motor drive built by the University of Arkansas, a solid-state circuit breaker (iBreaker) built by the Illinois Institute of Technology, and a Flying Capacitor Multi-level (FCML) DC/DC converter built by the University of California, Berkeley. In each of these cases, the requirements established for safety of flight resulted in a holistic approach to the designs, evoking a deeper understanding of the potential failure modes and mitigations necessary to build a robust and flightworthy system. Further, the integration into a hybrid-electric aircraft de-risked the potential electrical and mechanical issues that cannot easily be experienced or replicated in a lab environment. The experiments were also required to undergo representative temperature, shock, and vibration testing as the FAA prescribes for this category of aircraft, facilitating familiarity with the relevant design and test guidelines necessary to commercialize the technologies. This testbed unlocks the massive potential of core power electronics technologies necessary for a safe, robust, and efficient electric aviation future. With quick iterative design, test, and flight cycles, these core technologies are on a quicker path to technology readiness level maturity and commercialization, enabling a more sustainable future for the aviation industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Logic controlled solid state switchgear

Logic controlled solid state circuit breakers and power transfer switches have been designed and built to demonstrate their use for 270 V dc power systems. This switchgear provides remote operation, automatic current level, and operates several orders of magnitude faster with much greater accuracy of response than conventional switchgear.

Buchanan, E.↗

A High Power Density Power System Electronics for NASA's Lunar Reconnaissance Orbiter

A high power density, modular and state-of-the-art Power System Electronics (PSE) has been developed for the Lunar Reconnaissance Orbiter (LRO) mission. This paper addresses the hardware architecture and performance, the power handling capabilities, and the fabrication technology. The PSE was developed by NASA s Goddard Space Flight Center (GSFC) and is the central location for power handling and distribution of the LRO spacecraft. The PSE packaging design manages and distributes 2200W of solar array input power in a volume less than a cubic foot. The PSE architecture incorporates reliable standard internal and external communication buses, solid state circuit breakers and LiIon battery charge management. Although a single string design, the PSE achieves high reliability by elegantly implementing functional redundancy and internal fault detection and correction. The PSE has been environmentally tested and delivered to the LRO spacecraft for the flight Integration and Test. This modular design is scheduled to flight in early 2009 on board the LRO and Lunar Crater Observation and Sensing Satellite (LCROSS) spacecrafts and is the baseline architecture for future NASA missions such as Global Precipitation Measurement (GPM) and Magnetospheric MultiScale (MMS).

Hernandez-Pellerano, A.↗

Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid (AVC-TeDP)

The purpose of this effort was to advance the selection, characterization, and modeling of a propulsion electric grid for a Turboelectric Distributed Propulsion (TeDP) system for transport aircraft. The TeDP aircraft would constitute a miniature electric grid with 50 MW or more of total power, two or more generators, redundant transmission lines, and multiple electric motors driving propulsion fans. The study proposed power system architectures, investigated electromechanical and solid state circuit breakers, estimated the impact of the system voltage on system mass, and recommended DC bus voltage range. The study assumed an all cryogenic power system. Detailed assumptions within the study include hybrid circuit breakers, a two cryogen system, and supercritical cyrogens. A dynamic model was developed to investigate control and parameter selection.

power↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Solid-state recoverable fuse functions as circuit breaker

Molded, conductive-epoxy recoverable fuse protects electronic circuits during overload conditions, and then permits them to continue to function immediately after the overload condition is removed. It has low resistance at ambient temperature, and high resistance at an elevated temperature.

Thomas, E. F., Jr.↗

Logic-controlled solid state switchgear for 270 volts dc

A feasibility study to design and demonstrate solid state switchgear in the form of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 V dc circuit and controls power to a load of up to 15 amperes. One circuit breaker may be interconnected to a second breaker to form a power transfer switch. On-off and transfer functions of the breakers or the transfer switch are remotely controlled. A number of reclosures with variable time delay between tripout and reclosure are programmed and controlled by integrated analog and COSMOS logic circuits. A unique commutation circuit, that generates only minimal transient disturbance to either source or load, was developed to interrupt current flow through the main SCR switching element. Laboratory tests demonstrated performance of the solid state circuit breakers over specified voltage and temperature ranges.

Sundberg, G. R.↗