DOE OSTI2017
During operation, the PWR control rods are either completely extracted (scram or safety rods) or partially inserted in the operating zone of the core (fine control or operating rods). At the nominal rating conditions or close to them, the operating zone is limited to some steps of insertion in the order of a few tens of cm. In fact, only the lower part of the control rods are subjected to a significant neutron flux with an impact on the neutron activation and so on the waste classification (Low Level Short-lived Waste versus Intermediate Level Long-lived Waste). Our calculative as well as experimental experience confirms the significant presence of radionuclides in the control rods, but only in the lower parts. Measuring, cutting and finally sorting control rod scraps can reduce the volume of Intermediate Level Long-lived Waste planned for our storage deposit facility. This paper presents the EDF/DP2D methodologies followed to determine the sort criteria between the Low Level Short-lived Waste versus the Intermediate Level Long-lived Waste zones for the Silver-Indium-Cadmium control rods. The irradiated control rods are stored in cases without their head. Each case can contain several control rods, and the cases are stored under water in the fuel assembly pool. To calculate the radioactive inventories, we have developed a calculation scheme which is composed of a 3-dimensional mapping of the neutron flux, a calculation of the evolution of the isotopic compositions under neutron flux and finally a comparison between calculated and measured values. The main hypotheses of the control rods calculation take into account: - 3-dimensional geometry and 3-dimensional neutron sources distribution, - the isotopic compositions including impurities, - the history of irradiation resulting mainly from the daily power production, the positions of the control rods in the loading patterns and the positions in the axial operating zone. In order to validate the calculations, measurements were made 20 meters under water in the fuel assembly pool. The experimental results show the presence of many gamma emitter radionuclides. Only Ag-108m was retained for validating the calculations. This is due to the fact that silver is considered as the 'standard' chemical element for our control rods and silver produces Ag-108m which is a long-lived gamma emitter radionuclide. The analysis of the calculated results and the measured values allow us to build a simplified physics model for the simulation of the control rods activation. Finally three sort criteria can be proposed: - Without measurement devices, the sorting is based on an empirical sort criterion. Cuttings must then be made on the 2 back-ends of the control rod pins. This option is due to the difficulty in knowing the orientation of the pins in the storage cases. The cutting lines are placed at approximately 1 m from the 2 back-ends of the pins. This approach does not allow a great optimization of the sorting, less than 50% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With a simple dose rate measurement device, the knowledge of the orientation of the pins in the storage cases allows us to limit cuttings to the lower part of the control rods. Depending on the 'top to tail' cases, between approximately 50% and 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With an accurate measurement device, the sorting can be based on a specific activity of Ag-108m. Over 4400 Bq/g of Ag-108m (corresponding to the Intermediate Level Long-lived Waste limit), the control rod pieces can be considered as a long-lived waste. The measurements must be made over the 2 back-ends of control rod pins to examine the cases of 'top to tail' storage. This approach allows a great optimization of the sorting. Depending on the history of irradiation, more than 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. (author)
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗