Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sound level meters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Differential sound-level meter

Relative difference between sound-levels at two different microphone sites is measured precisely with circuit that continuously monitors gains of two acoustical channels. Difference between two pilot voltages is utilized in regulating loop to force gain of second channel to track gain of first channel.

Zuckerwar, A. J.↗

Differential sound level meter

Small differences between relatively high sound pressure levels at two different microphone sites are measured by a device which provides electrical insertion voltages (pilot voltages) as a a means for continuously monitoring the gains of two acoustical channels. The difference between two pilot voltages is utilized to force the gain of one channel to track the other channel.

Zuckerwar, A. J.↗

Visible Contrast Energy Metrics for Detection and Discrimination

Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images

Ahumada, Albert↗

Environmental noise assessment STS-1 Columbia launch

An environmental noise assessement of the initial launch of the Space Transportation System, STS-1 Columbia was conducted. The principal objective of the environmental noise assessment was to measure the noise generated during the initial launch of the space shuttle to ascertain the validity of the levels predicted in the 1979 environmental impact statement. In the 1979 study information obtained for expendable launch vehicles, Titan, Saturn and Atlas was used to predict the noise levels that would be generated by the simultaneous firing of the two solid rocket boosters and the three space shuttle main engines. Fifteen monitoring sites were established in accessable areas located from 4,953 to 23,640 meters from the launch pad. Precision sound level meters were used to capture the peak level during the launch. Data obtained was compared to the predicted levels and were also compared to the identified levels, standards and criteria established by the federal agencies with noise abatement and control responsibilities.

Putnicki, G. J.↗

A Sound Pressure-level Meter Without Amplification

The N.A.C.A. has developed a simple pressure-level meter for the measurement of sound-pressure levels above 70 db. The instrument employs a carbon microphone but has no amplification. The source of power is five flashlight batteries. Measurements may be made up to the threshold of feeling with an accuracy of plus or minus 2 db; band analysis of complex spectra may be made if desired.

Stowell, E Z↗

Exploratory investigation of sound pressure level in the wake of an oscillating airfoil in the vicinity of stall

Wind tunnel tests were performed on two oscillating two-dimensional lifting surfaces. The first of these models had an NACA 0012 airfoil section while the second simulated the classical flat plate. Both of these models had a mean angle of attack of 12 degrees while being oscillated in pitch about their midchord with a double amplitude of 6 degrees. Wake surveys of sound pressure level were made over a frequency range from 16 to 32 Hz and at various free stream velocities up to 100 ft/sec. The sound pressure level spectrum indicated significant peaks in sound intensity at the oscillation frequency and its first harmonic near the wake of both models. From a comparison of these data with that of a sound level meter, it is concluded that most of the sound intensity is contained within these peaks and no appreciable peaks occur at higher harmonics. It is concluded that within the wake the sound intensity is largely pseudosound while at one chord length outside the wake, it is largely true vortex sound. For both the airfoil and flat plate the peaks appear to be more strongly dependent upon the airspeed than on the oscillation frequency. Therefore reduced frequency does not appear to be a significant parameter in the generation of wake sound intensity.

Gray, R. B.↗

Comparison of Two Digital Stethoscopes with the Traditional Stethoscope Used on International Space Station

A traditional stethoscope is currently flown on the International Space Station (ISS). The background noise on the ISS is much higher than a normal exam room, and the literature shows that traditional stethoscopes are unable to function effectively in high noise environments. Digital stethoscopes provide amplification which improves the audibility in a quiet environment. This study is designed to determine if digital stethoscopes offer any advantage over traditional stethoscopes in being able to identify normal and abnormal sounds in the ISS noise environment. Methods: An ISS noise simulation facility was created to reproduce ISS noise profiles by modifying pink noise with a software-based graphic equalizer. The files were played in a continuous loop on a computer, amplified through a high-end stereo system and adjusted using a sound level meter. Nine caregiver analogues were given the same auscultation lesson received by astronauts. They began testing by becoming familiar with normal and abnormal sounds on a Student Auscultation Manikin . They then used two digital stethoscopes and a traditional stethoscope identical to the one flown on the ISS to auscultate the manikin sounds in the noise facility. They identified the sounds on a questionnaire and picked which of the three stethoscopes they preferred. Results: Evaluators displayed equivalent accuracy in sound identification when using either the 3M model 4000 digital stethoscope or traditional stethoscope. However, the 3M was preferred 2 to 1 by the evaluators, primarily because of additional amplification of the sounds. Discussion: Although our results show that the current ISS stethoscope and the "best-of-breed" digital stethoscope provide essentially the same auscultation utility, the latter has the advantage of recording and transmitting sounds to a remote physician. Since the astronaut caregivers are non-physiCians, this capability may be worth the additional expense and effort needed to certify the digital stethoscope for flight.

Rasbury, Jack↗

Noise levels and their effects on Shuttle crewmembers' performance: Operational concerns

When excessive, noise can result in sleep interference, fatigue, interference with verbal communication, and hearing damage. Shuttle crewmembers are exposed to noise throughout their mission. The contribution of noise to decrements in crew performance over these extended exposure durations was the focus of this study. On the STS-40/SLS-1, mission noise levels were evaluated through the use of a sound level meter and a crew questionnaire. Crewmembers noted that sleep, concentration, and relaxation were negatively impacted by high noise levels. Speech Interference Levels (SIL's), calculated from the sound level measurements, suggested that crewmembers were required to raise their voice in order to be heard. No difficulty detecting caution and warning alarms was noted. The higher than desirable noise levels in Spacelab were attributed to flight specific payloads for which acoustic waivers were granted. It is recommended that current noise levels be reduced in Spacelab and the Orbiter Middeck especially as longer missions are planned for the buildup of Space Station Freedom. Levels of NC 50 are recommended in areas where speech communication is required and NC 40 in sleep areas. These levels are in accordance with the NASA Man-Systems Integration Standards. Measurements proposed for subsequent orbiter missions are discussed.

Koros, Anton S.↗

Reliability of laboratory tests of VSTOL and other long duration noises

Paired-comparison and magnitude estimations of the subjective noisiness or unacceptability of noise from fixed wing jet aircraft and simulated noise of VSTOL aircraft were obtained from groups of subjects given different instructions. These results suggest that VSTOL noises can be evaluated in terms of their noisiness or unwantedness to people with reasonable accuracy by units of the physical measures designated as PNdBM, with or without tone corrections, and dBD sub 2. Also, that consideration should be given to the use of D sub 2 as an overall frequency weighting function for sound level meters instead of the presently available A weighting. Two new units of noise measurement, PLdB and dB(E), used for predicting subjective noisiness, were found to be less accurate than PNdBM or dBD sub 2 in this regard.

Kryter, K. D.↗

A simple violin oscillator

For acoustic tests the violin is driven laterally at the bridge by a small speaker of the type commonly found in pocket transistor radios. An audio oscillator excites the tone which is picked up by a sound level meter. Gross patterns of vibration modes are obtained by the Chladni method.

Jones, R. T.↗

Acoustics Critical Readiness Review

This presentation reviews the status of the acoustic equipment from the medical operations perspective. Included is information about the acoustic dosimeters, sound level meter, and headphones that are planned for use while on orbit. Finally there is information about on-orbit hearing assessments.

Ballard, Kenny↗

International Space Station Acoustics - A Status Report

It is important to control acoustic noise aboard the International Space Station (ISS) to provide a satisfactory environment for voice communications, crew productivity, and restful sleep, and to minimize the risk for temporary and permanent hearing loss. Acoustic monitoring is an important part of the noise control process on ISS, providing critical data for trend analysis, noise exposure analysis, validation of acoustic analysis and predictions, and to provide strong evidence for ensuring crew health and safety, thus allowing Flight Certification. To this purpose, sound level meter (SLM) measurements and acoustic noise dosimetry are routinely performed. And since the primary noise sources on ISS include the environmental control and life support system (fans and airflow) and active thermal control system (pumps and water flow), acoustic monitoring will indicate changes in hardware noise emissions that may indicate system degradation or performance issues. This paper provides the current acoustic levels in the ISS modules and sleep stations, and is an update to the status presented in 20031. Many new modules, and sleep stations have been added to the ISS since that time. In addition, noise mitigation efforts have reduced noise levels in some areas. As a result, the acoustic levels on the ISS have improved.

Allen, Christopher S.↗

International Space Station Acoustics - A Status Report

It is important to control acoustic noise aboard the International Space Station (ISS) to provide a satisfactory environment for voice communications, crew productivity, alarm audibility, and restful sleep, and to minimize the risk for temporary and permanent hearing loss. Acoustic monitoring is an important part of the noise control process on ISS, providing critical data for trend analysis, noise exposure analysis, validation of acoustic analyses and predictions, and to provide strong evidence for ensuring crew health and safety, thus allowing Flight Certification. To this purpose, sound level meter (SLM) measurements and acoustic noise dosimetry are routinely performed. And since the primary noise sources on ISS include the environmental control and life support system (fans and airflow) and active thermal control system (pumps and water flow), acoustic monitoring will reveal changes in hardware noise emissions that may indicate system degradation or performance issues. This paper provides the current acoustic levels in the ISS modules and sleep stations and is an update to the status presented in 2011. Since this last status report, many payloads (science experiment hardware) have been added and a significant number of quiet ventilation fans have replaced noisier fans in the Russian Segment. Also, noise mitigation efforts are planned to reduce the noise levels of the T2 treadmill and levels in Node 3, in general. As a result, the acoustic levels on the ISS continue to improve.

Allen, Christopher S.↗

Airframe noise of the DC-9

Airframe noise measurements are reported for the DC-9-31 aircraft flown at several speeds and with a number of flap, landing gear, and slat extension configurations. The data are corrected for atmospheric attenuation and spherical divergence, and are presented for an overhead position normalized to a 1-meter height. The sound pressure levels are found to vary approximately as the fifth power of flight velocity. Both lift and drag dipoles exist as a significant part of the airframe noise. The data are compared with airframe noise predictions using the drag element and the data analysis methods. Although some of the predictions are very good, further work is needed to refine these methods, particularly for the gear-down and flaps-down configurations.

Bauer, A. B.↗

Airframe noise of the DC-9-31

Airframe noise measurements are reported for the DC-9-31 aircraft flown at several speeds and with a number of flap, landing gear, and slat extension configurations. The data are corrected for wind effects, atmospheric attenuation, and spherical divergence, and are normalized to a 1 meter acoustic range. The sound pressure levels are found to vary approximately as the fifth power of flight velocity. Both lift and drag dipoles exist as a significant part of the airframe noise. The sideline data imply that a significant side-force dipole exists only for the flap- and gear-down configurations; for others, the data imply the existence of only the lift and drag dipoles. The data are compared with airframe noise predictions using the drag element and the data analysis methods. Although some of the predictions are good, further work is needed to refine the methods, particularly for the flap- and gear-down configurations.

Bauer, A. B.↗

Sonic Boom Ocean Penetration: Noise Metric Comparison and Initial Focusing Results

The purpose of the present research is to determine the impact by sonic boom noise penetration into the ocean. Since the 1994 LaRC High Speed Research Program Sonic Boom Workshop several new results have been obtained. This talk reviews these results, and emphasizes the two most important findings. The first major result is an improved understanding of the noise spectra of the penetrating sonic boom. It was determined that weighted sound exposure levels decrease with deeper ocean depths significantly faster than unweighted sound exposure levels. This is because low frequencies penetrate the ocean deeper than high frequencies. Several noise metrics were used including peak, SEL, C-SEL, A-SEL, and PLdB, and results are given for all. These results are important because they show that the sonic boom noise impact on marine life a few meters below the ocean surface may be significantly lower using weighted sound levels than if one were to measure the impact using unweighted levels. The other major finding is the first estimate of the worst case peak levels produced by a penetrating sonic boom being focused by a sinusoidal ocean surface. The method of analysis chosen was computational, a time domain finite difference algorithm. The method is outlined and then example results are presented. For rounded sonic boom waveforms incident on a sinusoidal ocean surface, it is shown that the percentage increase or decrease in pressure is only occasionally larger than 10%, rarely 25%. These fluctuations indicate, under the assumptions already given, that any increase or decrease in sound level underwater due to focusing or defocusing should be small, less than 3 dB.

Sparrow, Victor W.↗

WOBBLE: A Proposed Mission to Characterize Past and Present Water on Mars

WOBBLE ("Water Observations from a Balloon Borne Light Explorer") is a mission concept study for a small robotic probe to explore Mars and to accomplish a scientific mission compatible with the goals of the NASA Code S enterprise. The detection of past or present water is a crucial goal for Mars exploration, representing a cross-cutting science theme relevant to past or extant life, climate history, sample return missions and eventual human exploration. The WOBBLE mission concept was developed to study evidence of water using in-situ detection methods. The features on Mars most suited to this investigation are the gullies identified by Malin and Edgett as evidence for recent, near-surface runoff of liquid water. These features are typically located on the inside face of crater rims, where the local slope angle is at or near the angle of repose. This makes the terrain difficult or impossible to access with conventional wheeled rover technology. Combined with the small size of the gullies in relation to a standard landing error ellipse, scientific investigation of these features requires a new approach to surface mobility. WOBBLE uses a low-altitude balloon-borne platform to traverse the surface from the landing site, to the investigation site, and then rise up the slope to investigate the regions of interest at close range. Of the mobility technologies available for near-term Mars exploration, only a balloon platform is capable of a well targeted, detailed sampling of the gully regions over periods of days or more. The science approach embodied in WOBBLE is two-pronged, designed to investigate both the historical evidence of liquid water utilizing high-resolution geomorphology and the characterization of mineral deposits, and present subsurface liquid water using radar sounding techniques. The WOBBLE balloon is a high-pressure hydrogen gas design, 24 meters in diameter and lifting a total payload of 130 kg, including a high-resolution camera/IR imager, Raman spectrometer, and a ground penetrating radar (GPR) sounder. The stowed balloon and payload are designed to fit within the current airbag delivery system being built for the Mars Exploration Rovers. Characterization of local meteorological conditions and wind is made over the initial sols following landing and before balloon inflation. Following balloon inflation and launch, a controlled, targeted approach toward the identified regions of interest is made in a series of several low-altitude "hops," with the balloon tethered to the ground between the hop intervals. A "snake" system is used to control the altitude to a few tens of meters above the local ground level. Enroute to the target gully, GPR soundings and Raman spectroscopy measurements study past or present water, while continued camera bearings and meteorological measurements refine the next "hop" trajectory. Once at the gully/outflow region, GPR and Raman soundings continue while the camera obtains detailed, approx. 0.5 cm images for geomorphology studies. The WOBBLE concept is applicable to Mars Scout, Mars Surveyor, or Discovery class missions.

Udrea, Bogdan↗

Improvement of the predicted aural detection code ICHIN (I Can Hear It Now)

Acoustic tests were conducted to study the far-field sound pressure levels and aural detection ranges associated with a Sikorsky S-76A helicopter in straight and level flight at various advancing blade tip Mach numbers. The flight altitude was nominally 150 meters above ground level. This paper compares the normalized predicted aural detection distances, based on the measured far-field sound pressure levels, to the normalized measured aural detection distances obtained from sound jury response measurements obtained during the same test. Both unmodified and modified versions of the prediction code ICHIN-6 (I Can Hear It Now) were used to produce the results for this study.

Mueller, Arnold W.↗