Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Contaminant Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Updated Analysis of the Trash Compaction and Processing System: Water Collected from Trash, Evaluation of the Source Contaminant Control System, and Zotek® F30 Foam Processing

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). At NASA Ames Research Center (ARC), there are two test systems: the Heat Melt Compactor (HMC), which compacts the trash into a tile with temperature and pressure, and the Source Contaminant Control System (SCCS), which is the gas management subsystem aimed to reduce contaminants by converting them into carbon dioxide (CO 2 ) and water (H 2 O) vapor. Both the HMC and SCCS serve as test systems that support TCPS development by conducting risk reduction activities associated with an ISS technology demonstration. In this paper, the risk reduction activities discussed are the testing of different trash models for operational scenarios in the HMC, investigating the water extracted from those trash models, and managing the gaseous effluents from the trash via contaminant conversion through the SCCS. The HMC has undergone several tests of different trash models and cases in which a containment bag is used or not. For the first topic, this paper will analyze the water collected and recovered from these tests and analyze the effect of specific trash containment bags. For the second topic, this paper will individually evaluate the carbon bed and catalytic oxidizer (CatOx) to understand what components the carbon bed removes and what contaminants are converted in the CatOx. For the third and final topic, this paper will discuss Zotek® F30 foam processing in the HMC unit and testing verification in correlation to defined TCPS requirements. A foam model was added to reduce the volume of foam that take up space in the ISS. Overall, this paper is a compilation and an updated analysis of tests conducted in the lab-scale TCPS at ARC within the past year.

TCPS↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

Updated Analysis of the Source Contaminant Control System (SCCS) for the Trash Compaction and Processing System (TCPS)

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. A Source Contaminant Control System (SCCS) is planned to be implemented within the TCPS to convert these contaminants into carbon dioxide (CO 2 ) and water (H 2 O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO 2 and H 2 O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). This paper will individually evaluate the carbon bed and CatOx to understand what components the carbon bed removes and what contaminants are converted in the CatOx. Overall, this is an updated analysis of the SCCS design, operation, testing with results, and lessons learned.

Janine Criselda Young↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2 and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2 conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

Janine Young↗

Space station trace contaminant control

Different systems for the control of space station trace contaminants are outlined. The issues discussed include: spacecabin contaminant sources, technology base, contaminant control system elements and configuration, approach to contaminant control, contaminant load model definition, spacecraft maximum allowable concentrations, charcoal bed sizing and performance characteristics, catalytic oxidizer sizing and performance characteristics, special sorbent bed sizing, animal and plant research payload problems, and emergency upset contaminant removal. It is concluded that the trace contaminant control technology base is firm, the necessary hardware tools are available, and the previous design philosophy is still applicable. Some concerns are the need as opposed to danger of the catalytic oxidizer, contaminants with very low allowable concentrations, and the impact of relaxing materials requirements.

Olcutt, T.↗

Skylab contamination control

The optical contamination control systems of Skylab are reviewed, covering contamination sources, critical elements, flight hardware configuration, contamination monitoring sensors, mathematical contamination prediction models, contamination cloud and deposition models, and hardware implementation. Also considered are supportive contamination tests, contamination mission support activities, Skylab contamination evaluation, contamination measurement experiments, and the effectiveness of contamination control measures. Sources of contamination are identified, Skylab system susceptibility to contamination is determined, and predictions are made for surface contamination deposition and background brightness levels. Mission evaluation results indicate that, barring anomalous conditions, Skylab mission equipment and activities are adequate to reduce the general contamination level to the sensitivity threshold levels for experiments and affected subsystems.

Davis, C. M.↗

A comparison of shuttle vernier engine plume contamination with CONTAM 3.4 code predictions

In 1985, using the CONTAM 3.2 code, it was predicted that the shuttle Primary Reaction Control System (PRCS) and Vernier Reaction Control System (VRCS) engines could be potential contamination sources to sensitive surfaces located within the shuttle payload bay. Spaceflight test data on these engines is quite limited. Shuttle mission STS-32, the Long Duration Exposure Facility retrieval mission, was instrumented with an experiment that provided the design engineer with evidence that contaminant species from the VRCS engines can enter the payload bay. More recently, the most recent version of the analysis code, CONTAM 3.4, has re-examined the contamination potential of these engines.

Maag, Carl R.↗

Oxides in NaK

Oxygen reactivity effects on eutectic NaK alloy and SNAP 8 system including oxygen contamination sources, oxide solubility, and oxide control methods

Cassidy, F. H.↗

Ammonia Stability in a Simulated Trace Contaminant Rich Cabin Environment

The off-gassing of ammonia from hardware and metabolic sources presents a unique challenge to trace contaminant control system design, driving process flowrates to meet crewed air quality requirements. Accurately simulating representative trace contaminant cabin loads during ground testing is necessary to validate component design as well as understand potential contaminant propagation across life-support system process interface boundaries. This effort is complicated by the observed temporal concentration instability of gaseous ammonia in ground test chambers. To this end, ammonia concentration decay rates were characterized under controlled environmental conditions to better understand underlying phenomena and quantify incidental mass losses. The suspected chemical interaction between ammonia and trace acetaldehyde was investigated and its effect on species quantification was examined by both gas chromatography-mass spectrometry and Fourier-transform infrared spectroscopy. Recommendations for ground test procedures were made in order to best compensate for undesirable ammonia mass losses and mitigate test artifacts.

Kayatin, Matthew J.↗

Internal contamination in the space station

Atmosphere trace contaminant control systems used in the past (Lunar Module and Skylab) and present (nuclear submarines and Shuttle) are discussed. Recommendations are made for the future Space Station contaminant control system. The prevention and control methods used are judicious material selection, detection, and specific removal equipment. Sources and effects of contamination relating to crew and equipment are also discussed.

Poythress, C.↗

The Plume Impingement Contamination II Experiment: Motivation, Design, and Implementation Plan

The International Space Station (ISS) will have a long service life during which it must be able to serve as a capable platform for a wide variety of scientific investigations. In order to provide this capability, the ISS has, at the system level, a design requirement of no more than 100 Angstroms of contaminant deposition per year from "non-quiescent" sources. Non-quiescent sources include the plumes resulting from the firing of reaction control system (ReS) engines on space vehicles visiting the ISS as well as the engines on the ISS itself. Unfortunately, good general plume contamination models do not yet exist. This is due both to the complexity of the problem, making the analytic approach difficult, and to the difficulty in obtaining empirical measurements of contaminant depositions. To address this lack of flight data, NASA Johnson Space Center is planning to fly an experiment, Plume Impingement Contamination-II, to measure the contamination deposition from the Shuttle Orbiter's primary RCS engines as a function angle from plume centerline. This represents the first direct on-orbit measurement of plume impingement contamination away from the nozzle centerline ever performed, and as such is extremely important in validating mathematical models which will be used to quantify the cumulative plume impingement contamination to the ISS over its lifetime. The paper will elaborate further upon the motivation behind making these measurements as well as present the design and implementation plan of this planned experiment.

Lumpkin, Forrest E., III↗

Environmental Verification Experiment for the Explorer Platform (EVEEP)

Satellites and long-life spacecraft require effective contamination control measures to ensure data accuracy and maintain overall system performance margins. Satellite and spacecraft contamination can occur from either molecular or particulate matter. Some of the sources of the molecular species are as follows: mass loss from nonmetallic materials; venting of confined spacecraft or experiment volumes; exhaust effluents from attitude control systems; integration and test activities; and improper cleaning of surfaces. Some of the sources of particulates are as follows: leaks or purges which condense upon vacuum exposure; abrasion of movable surfaces; and micrometeoroid impacts. The Environmental Verification Experiment for the Explorer Platform (EVEEP) was designed to investigate the following aspects of spacecraft contamination control: materials selection; contamination modeling of existing designs; and thermal vacuum testing of a spacecraft with contamination monitors.

Norris, Bonnie↗

Lessons Learned in Designing A Proposed Ultraviolet Sterilization System for Space

This paper presents a number of lessons learned while designing a proposed sterilization system for Mars Sample Return. This sterilization system is needed to inactivate any potentially hazardous Mars material on the exterior surface of the vessel containing sealed sample tubes filled with Mars rock cores, regolith and atmosphere. These returned samples would provide information on the geologic history of Mars, the evolution of its climate and the potential for ancient life. Mars Sample Return is categorized at Planetary Protection Category V Restricted Earth Return, so it is required to protect the Earth–Moon system from the biological impact of returning samples from Mars to Earth. This article reviews lessons learned in the development of a particular engineering implementation to support the protection of the Earth–Moon biosphere: the use of in situ ultraviolet LED illumination. The details of the biological efficacy of this approach or the policy-related impacts are outside of the scope of this manuscript. The lessons learned presented here include establishing design requirements for the system, the selection of a light source, optical design options, contamination control and approaches to thermal and power management.

Planetary Protection↗

Trace Contaminant Control: An In-Depth Study of a Silica-Titania Composite for Photocatalytic Remediation of Closed-Environment Habitat Air

This collection of studies focuses on a PCO system for the oxidation of a model compound, ethanol, using an adsorption-enhanced silica-TiO2 composite (STC) as the photocatalyst; studies are aimed at addressing the optimization of various parameters including light source, humidity, temperature, and possible poisoning events for use as part of a system for gaseous trace-contaminant control system in closed-environment habitats. The first goal focused on distinguishing the effect of photon flux (i.e., photons per unit time reaching a surface) from that of photon energy (i.e., wavelength) of a photon source on the PCO of ethanol. Experiments were conducted in a bench-scale annular reactor packed with STC pellets and irradiated with either a UV-A fluorescent black light blue lamp O max=365 nm) at its maximum light intensity or a UV-C germicidal lamp O. max=254 nm) at three levels of light intensity. The STC-catalyzed oxidation of ethanol was found to follow zero-order kinetics with respect to CO2 production, regardless of the photon source. Increased photon flux led to increased EtOH removal, mineralization, and oxidation rate accompanied by lower intermediate concentration in the effluent. The oxidation rate was higher in the reactor irradiated by UV-C than by UV-A (38.4 vs. 31.9 nM s-1 ) at the same photon flux, with similar trends for mineralization (53.9 vs. 43.4%) and reaction quantum efficiency (i.e., photonic efficiency, 63.3 vs. 50.1 nmol C02 ~mol photons-1 ). UV-C irradiation also led to decreased intermediate concentration in the effluent compared to UV -A irradiation. These results demonstrated that STC-catalyzed oxidation is enhanced by both increased photon flux and photon energy. The effect of temperature and relative humidity on the STC-catalyzed degradation of ethanol was also determined using the UV-A light source at its maximum intensity.

Coutts, Janelle L.↗

Experimental system, and its evaluation for the control of surgically inducted infections

The effect is reported to design, fabricate, test and evaluate a prototype experimental system for the control of surgically induced infections. The purpose is to provide the cleanest possible environment within a hospital surgery room and eliminate contamination sources that could cause infections during surgery. The system design is described. The system provides for a portable laminar flow clean room, a full bubble helmet system with associated communications and ventilation subsystems for operating room personnel, and surgical gowns that minimize the migration of bacteria. The development test results consisting of portability, laminar flowrate, air flow pattern, electrostatic buildup, noise level, ventilation, human factors, electrical and material compatibility tests are summarized. The conclusions are that the experimental system is effective in reducing the airborne and wound contamination although the helmets and gowns may not be a significant part of this reduction. Definitive conclusions with regard to the infection rate cannot be made at this time.

Tevebaugh, M. D.↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

Trace chemical contaminant generation rates for spacecraft contamination control system design

A spacecraft presents a unique design challenge with respect to providing a comfortable environment in which people can live and work. All aspects of the spacecraft environmental design including the size of the habitable volume, its temperature, relative humidity, and composition must be considered to ensure the comfort and health of the occupants. The crew members and the materials selected for outfitting the spacecraft play an integral part in designing a habitable spacecraft because material offgassing and human metabolism are the primary sources for continuous trace chemical contaminant generation onboard a spacecraft. Since these contamination sources cannot be completely eliminated, active control processes must be designed and deployed onboard the spacecraft to ensure an acceptably clean cabin atmosphere. Knowledge of the expected rates at which contaminants are generated is very important to the design of these processes. Data from past spacecraft missions and human contaminant production studies have been analyzed to provide this knowledge. The resulting compilation of contaminants and generation rates serve as a firm basis for past, present, and future contamination control system designs for space and aeronautics applications.

Perry, J. L.↗

Causes and control of solar electric propulsion interactive effects

Contaminant effects and questions of thrust system operation status are discussed together with the sources of contaminant effects and the areas of contaminant impact. Contaminant reduction techniques are considered, giving attention to magnetic contamination, dc electric contamination, ac electric contamination, conducted EM interference, radio frequency interference, and material transport and deposition. Design goals for the reduction of contaminant levels are examined along with some areas of uncertainty.

Sellen, J. M., Jr.↗