Tunable resonator-based devices for producing variable delays and narrow spectral linewidths

Devices with two or more coupled resonators to produce narrow spectral responses due to interference of signals that transmit through the resonators and techniques for operating such devices to achieve certain operating characteristics are described. The devices may be optical devices where optical resonators such as whispering gallery mode resonators may be used. In one implementation, at least one of the coupled optical resonators is a tunable resonator and is tuned to change its resonance frequency to tune the spectral response of the device. The described devices and techniques may be applied in optical filters, optical delays, optical waveform generators, and other applications.

Savchenkov, Anatoliy↗

Vibrational dependence of pressure induced spectral linewidths and line shifts - Application of the infinite order sudden scattering approximation

The infinite order sudden (IOS) approximation to molecular rotation is applied to simplify the theory of linewidths and shifts in vibration-rotation spectra. This approximation is expected to be most accurate for hard, short-range collisions and is therefore complementary to Anderson theory which is best for weak, glancing collisions. The IOS approximation predicts identical linewidths and shifts for P- and R-branch transitions with the same line number. It also predicts zero line shifts for pure rotational spectra. The dependence of linewidths and shifts on vibrational band is seen to be due mainly to variation in diagonal vibrational matrix elements of the intermolecular potential. Calculations are performed for the 0-0, 0-1, and 0-2 bands of CO perturbed by He, using a theoretical interaction potential with no semiempirical or adjustable parameters; results are in satisfactory accord with experimental data.

Green, S.↗

Ultranarrow linewidth, magnetically switched, long pulse, xenon chloride laser

A spectral linewidth of less than 70 fm and diffraction-limited beam divergence have been obtained from a long-pulse, electric-discharge xenon chloride laser with intracavity Fabry-Perot etalons. A gain duration of 100 ns provided for multipass operation of the etalons, significantly improving both contrast and finesse. The electrical-discharge circuit required to produce this long gain duration was comprised of a pulse-forming network, a saturable-inductor magnetic switch, and a tapered constant-impedance interface transmission line.

Pacala, T. J.↗

Linewidth broadening due to longitudinal spatial hole burning in a long distributed feedback laser

The spectral linewidth of a long distributed feedback (DFB) laser above threshold at high output power is investigated theoretically. Longitudinal spatial hole burning (LSHB) is shown to have important effects on the lasing characteristics and the broadening of linewidth. A four-wave coupled mode equation is developed to describe the LSHB phenomenon. The threshold gain and the carrier distribution are solved self-consistently above threshold at various output powers. The simulation results show that the power-linewidth product can increase by a factor greater than 2 due to LSHB for long DFB lasers. This theory has important implications on the limits of linewidth reduction by increasing the length of DFB lasers and on possible future device design for coherent optical systems.

Wu, Ming-Chiang↗

High Spectral Purity, Narrow Linewidth Laser Transmitter for Dial Measurements

A laser transmission with very high degree of spectral purity was described. Amplified Spontaneous Emission (ASE) dependence on the oscillator energy and the detuning away from the gain curve center are demonstrated. The effects of both finite laser linewidth and spectral purity on humidity measurements are experimentally demonstrated.

Singh, U. N.↗

Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection

A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.

Non-NASA Center↗

Yb fiber laser pumped mid-IR source based on difference frequency generation and its application to ammonia detection

A Yb fiber laser pumped cw narrow-linewidth tunable mid-IR source based on a difference frequency generation (DFG) in a periodically poled LiNbO3 (PPLN) crystal for trace gas detection was demonstrated. A high power Yb fiber laser and a distributed feedback (DFB) laser diode were used as DFG pump sources. This source generated mid-IR at 3 microns with a powers of ~2.5 microW and a spectral linewidth of less than 30 MHz. A frequency tuning range of 300 GHz (10 cm-1) was obtained by varying the current and temperature of the DFB laser diode. A high-resolution NH3 absorption Doppler-broadened spectrum at 3295.4 cm-1 (3.0345 microns) was obtained at a cell pressure of 27 Pa from which a detection sensitivity of 24 ppm m was estimated.

NASA Discipline Environmental Health↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Detection of NO sub x,C2H4 concentrations by using CO and CO2 lasers

A laser, especially the infrared line tunable laser, opens up a new way to monitor the atmospheric environment, and already has gotten effective practical application. One of the most serious problems in open path remote measurement at atmospheric pressure is the broadening effect which leads to increased linewidths, spectral interferences, and, as a result, tends to reduce detection sensitivity, so measuring laser wavelengths should be selected carefully, and interaction between the measuring wavelength and gas to be measured must be known very well. Therefore, N2O, No, NO2, CH4, NH3 and C2H4 absorption properties at some lines of CO and CO2 line tunable lasers were studied. The absorption coefficients of NO, NO2, and C2H4; some results on detection of NO sub x, C2H4 concentrations in both laboratory and field; and selection of measuring wavelengths and error analysis are discussed.

Gengchen, W.↗

A lidar system for measuring atmospheric pressure and temperature profiles

The design and operation of a differential absorption lidar system capable of remotely measuring the vertical structure of tropospheric pressure and temperature are described. The measurements are based on the absorption by atmospheric oxygen of the spectrally narrowband output of two pulsed alexandrite lasers. Detailed laser output spectral characteristics, which are critical to successful lidar measurements, are presented. Spectral linewidths of 0.026 and 0.018 per cm for the lasers were measured with over 99.99 percent of the energy contained in three longitudinal modes.

Schwemmer, Geary K.↗

Quasi-optical Josephson-junction oscillator arrays

Josephson junctions are natural voltage-controlled oscillators capable of generating submillimeter-wavelength radiation, but a single junction usually can produce only 100 nW of power and often has a broad spectral linewidth. The authors are investigating 2D quasi-optical power combining arrays of 103 and 104 NbN/MgO/NbN and Nb/Al-AlO(x)/Nb junctions to overcome these limitations. The junctions are dc-biased in parallel and are distributed along interdigitated lines. The arrays couple to a resonant mode of a Fabry-Perot cavity to achieve mutual phase-locking. The array configuration has a relatively low impedance, which should allow the capacitance of the junctions to be tuned out at the oscillation frequency.

Stern, J. A.↗

An Intense Slit Discharge Source of Jet-Cooled Molecular Ions and Radicals (T(sub rot) less than 30 K)

A novel pulsed, slit supersonic discharge source is described for generating intense jet-cooled densities of radicals (greater than 10(exp 12)/cu cm) and molecular ions (greater than 10(exp 10)/cu cm) under long absorption path (80 cm), supersonically cooled conditions. The design confines the discharge region upstream of the supersonic expansion orifice to achieve efficient rotational cooling down to 30 K or less. The collisionally collimated velocity distribution in the slit discharge geometry yields sub-Doppler spectral linewidths, which for open-shell radicals reveals spin-rotation splittings and broadening due to nuclear hyperfine structure. Application of the slit source for high-resolution, direct IR laser absorption spectroscopy in discharges is demonstrated on species such as OH, H3O(+) and N2H(+).

Anderson, David T.↗

The tropospheric emission spectrometer (TES) for the Earth Observing System (EOS)

In recent years, increasing concern has been expressed about Global Change - the natural and anthropogenic alteration of the Earth's environment involving global greenhouse warming and the associated climate change, urban and regional atmospheric pollution, acid deposition, regional increases in tropospheric zone, and the decrease in stratospheric ozone. A common theme among these problems is that they all involve those tropospheric trace gases which are fundamental to the biosphere-troposphere interaction, the chemistry of the free troposphere itself, and troposphere-stratosphere exchange. The chemical species involved all have spectral signatures within the near and mid infrared that can now be measured by advanced techniques of remote-sensing infrared spectroradiometry. Such a system is the Tropospheric Emission Spectrometer (TES), now in Phase B definition for the Earth Observing System (EOS) polar platforms. TES addresses these objectives by obtaining radiometrically calibrated, linewidth-limited spectral resolution, infrared spectra of the lower atmosphere using both natural thermal emission and reflected sunlight (where appropriate) in three different, but fully programmable, modes: a gobal mode, a pointed mode, and a limb-viewing mode. The goals of TES, its instrumentation, operational modes, sensitivity and data handling are discussed.

Beer, R.↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Matched tandem etalon camera - MATEC - and its application to auroral observations

The matched tandem etalon camera employs a Fabry-Perot interferometer (FP) in the photographic mode for the spatial resolution over all angles up to 7 deg from normal. An interference filter and an appropriate field lens isolate a single order of 0.1 A resolution, which is recorded simultaneously at all angles in the field of view by array detection. Thus the resolution and luminosity of the MATEC camera are those of the FP. The MATEC pilot model has a ratio of free spectral range to linewidth of 400 and utilizes intensified photographic detection. In a system applied to auroral measurements the MATEC views a semiconical sky mirror to provide a simulatenous dimension of spatial resolution in the N-S meridian combined with the dimension of spectral resolution. Stellar features and cloud and ground reflections are more easily identified than by any scanning photometer.

Young, E. R.↗

Broadening of fast-beam spectral lines due to diffraction at the entrance slit of a spectrometer.

Experimental and theoretical demonstration of the necessity to take into account the effects of diffraction at a spectrometer's entrance slit in adjusting the spectrometer for observation of fast-beam spectral lines under conditions of minimum linewidth. An approximate expression is obtained for the optimum entrance slit width to be used in order to avoid the pronounced broadening of the spectral lines that occurs for very narrow entrance slits.

Leavitt, J. A.↗

SUNLITE program. Sub-Hertz relative frequency stabilization of two diode laser pumped Nd:YAG lasers locked to a Fabry-Perot interferometer

Two laser pumped Nd:YAG lasers were frequency stabilized to a commercial 6.327 GHz free spectral range Fabry-Perot interferometer yielding a best case beatnote linewidth of 330 MHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27,500 was built, and when it was substituted in place of the commercial interferometer, it produced a robust and easily repeatable beatnote linewidth of 700 MHz.

Byer, R. L.↗