Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy, Fourier Transform Infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fourier Transform Infrared Spectroscopy of CF4 on the GEC Reference Cell

Fourier Transform Infrared Spectroscopy (FTIR) has been used to characterize inductively coupled CF4 plasmas in a GEC Reference Cell in-situ In examining these FTIR spectra, several assumptions and approximations of FTIR analysis are addressed. This includes the density dependence of cross-sections, non-linear effects in the addition of overlapping bands and the effect of spatial variations in density and temperature, This analysis demonstrates that temperatures extracted from MR spectra may provide a poor estimate of the true neutral plasma temperature. The FTIR spectra are dominated by unreacted CF, accounting for 40-60% of the gas products. The amount of CF4 consumption is found to have a marked dependence on power, and is nearly independent of pressure in the range of 10-50 mtorr. Small amounts of C2F6 are observed at low power. Also observed are etching products from the quartz window SiF4 COF2 and CO which occur in approximately equal ratios and together account for less than 10% of the gas. The concentrations of these species are nearly independent of pressure. CFx radicals are below the detection limit of this apparatus (approx. 1012/cc).

Rao, M. V. V. S.↗

Non-Destructive Evaluation of Polyolefin Thermal Aging Using Infrared Spectroscopy

Fourier transform infrared (FTIR) spectroscopy is an information-rich method that reveals chemical bonding near the surface of polymer composites. FTIR can be used to verify composite composition, identify chemical contaminants and expose composite moisture content. Polymer matrix changes due to thermal exposure including loss of additives, chain scission, oxidation and changes in crystallinity may also be determined using FTIR spectra. Portable handheld instruments using non-contact reflectance or surface contact attenuated total reflectance (ATR) may be used for non-destructive evaluation (NDE) of thermal aging in polymer and composite materials of in-service components. We report the use of ATR FTIR to track oxidative thermal aging in ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE) materials used in medium voltage nuclear power plant electrical cable insulation and jacketing. Mechanical property changes of the EPR and CPE materials with thermal degradation for correlation with FTIR data are tracked using indenter modulus (IM) testing. IM is often used as a local NDE metric of cable jacket health. The FTIR-determined carbonyl index was found to increase with IM and may be a valuable NDE metric with advantages over IM for assessing cable remaining useful life.

aging↗

Structures of aspartic acid-96 in the L and N intermediates of bacteriorhodopsin: analysis by Fourier transform infrared spectroscopy

The light-induced difference Fourier transform infrared spectrum between the L or N intermediate minus light-adapted bacteriorhodopsin (BR) was measured in order to examine the protonated states and the changes in the interactions of carboxylic acids of Asp-96 and Asp-115 in these intermediates. Vibrational bands due to the protonated and unprotonated carboxylic acid were identified by isotope shift and band depletion upon substitution of Asp-96 or -115 by asparagine. While the signal due to the deprotonation of Asp-96 was clearly observed in the N intermediate, this residue remained protonated in L. Asp-115 was partially deprotonated in L. The C = O stretching vibration of protonated Asp-96 of L showed almost no shift upon 2H2O substitution, in contrast to the corresponding band of Asp-96 or Asp-115 of BR, which shifted by 9-12 cm-1 under the same conditions. In the model system of acetic acid in organic solvents, such an absence of the shift of the C = O stretching vibration of the protonated carboxylic acid upon 2H2O substitution was seen only when the O-H of acetic acid is hydrogen-bonded. The non-hydrogen-bonded monomer showed the 2H2O-dependent shift. Thus, the O-H bond of Asp-96 enters into hydrogen bonding upon conversion of BR to L. Its increased hydrogen bonding in L is consistent with the observed downshift of the O-H stretching vibration of the carboxylic acid of Asp-96.

NASA Discipline Exobiology↗

Mechanistic aspects of plasma-enhanced catalytic methane decomposition by time-resolved operando diffuse reflectance infrared Fourier transform spectroscopy

To study mechanistic aspects of plasma-enhanced catalysis, methane is decomposed by a supported Ni catalyst assisted by an Ar/O 2 atmospheric pressure plasma jet (APPJ). Here, the time-resolved surface response of the Ni catalyst is investigated by operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) using various experimental settings. Catalyst temperatures of room temperature (RT) and 500 °C and nozzle-catalyst surface distances of 3, 5 and 8 mm were examined, and the amount of O 2 of the Ar/O 2 gas mixture flowing through the APPJ was either 0 or 0.5%. A synergistic effect of surface bonded C-O was observed during the exposure of the Ni catalyst to the APPJ for low oxygen operating conditions (pure Ar jet). Surface bonded C-O formed only when there was plasma present and the C-O signal was enhanced for higher catalyst temperature. When the supported Ni catalyst was subjected to the plasma-generated particle fluxes using highly oxidizing conditions, the presence of surface bonded C-O was suppressed. The plasma-catalytic CO and CO 2 production in the gas phase measured downstream mirrored the surface behavior of C-O bonds when the plasma source operating condition was changed from a low oxygen portion to a high oxygen portion at high catalyst temperature (500 °C). CH n (n =1, 2, ) species on the catalyst surface were also studied by DRIFTS, and CHn destruction was found to correlate with C-O formation. In particular, the time-resolved CH n response showed a possible conversion process of CH n to C-O when the Ni catalyst was exposed to the plasma source. This finding may indicate a plasma-mediated regeneration of the catalyst by plasma-catalyst surface interactions.

42 ENGINEERING↗

Trace Gas Measurements in Nascent, Aged and Cloud-processed Smoke from Africa Savanna Fires by Airborne Fourier Transform Infrared Spectroscopy (AFTIR)

We measured stable and reactive trace gases with an airborne Fourier transform infrared spectrometer (AFTIR) on the University of Washington Convair-580 research aircraft in August/September 2000 during the SAFARI 2000 dry season campaign in Southern Africa. The measurements included vertical profiles of C02, CO, H20, and CH4 up to 5.5 km on six occasions above instrumented ground sites and below the TERRA satellite and ER-2 high-flying research aircraft. We also measured the trace gas emissions from 10 African savanna fires. Five of these fires featured extensive ground-based fuel characterization, and two were in the humid savanna ecosystem that accounts for most African biomass burning. The major constituents we detected in nascent CH3OOH, HCHO, CH30H, HCN, NH3, HCOOH, and C2H2. These are the first quantitative measurements of the initial emissions of oxygenated volatile organic compounds (OVOC), NH3, and HCN from African savanna fires. On average, we measured 5.3 g/kg of OVOC and 3.6 g/kg of hydrocarbons (including CH4) in the initial emissions from the fires. Thus, the OVOC will have profound, largely unexplored effects on tropical tropospheric chemistry. The HCN emission factor was only weakly dependent on fire type; the average value (0.53 g/kg) is about 20 times that of a previous recommendation. HCN may be useful as a tracer for savanna fires. Delta O3/Delta CO and Delta CH3COO/Delta CO increased to as much as 9% in <1 h of photochemical processing downwind of fires. Direct measurements showed that cloud processing of smoke greatly reduced CH30H, NH3, CH3COOH, SO2, and NO2 levels, but significantly increased HCHO and NO.

Yokelson, Robert J.↗

A comprehensive review of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques in protonic ceramic cells (PCCs): Current status and future perspective

Protonic ceramic cells (PCCs) have emerged as a promising technology for power generation, energy storage, and value-added chemical synthesis, offering benefits such as fuel flexibility, low emissions, and efficient operation at intermediate temperatures (300–600 ​°C). Recently, significant breakthroughs in materials and manufacturing methods have markedly enhanced the performance of PCCs. However, establishing a fundamental understanding of their electrocatalytic reactions has gained less attention. As a fast and cost-effective method for physicochemical fingerprinting, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) has proven to be a surface-sensitive analytical tool for structural and functional studies. This review critically examines the most up-to-date applications of DRIFTS for characterizing key components of PCCs, including oxygen electrodes, protonic electrolytes, and hydrogen electrodes for different applications, with a focus on revealing hydration properties and catalytic reactions, and guiding rational material design. The challenges for advancing DRIFTS, including quantitative capabilities and operando applications for PCC investigations, are highlighted and strategies to tackle these challenges are discussed. Ultimately, this review underscores the critical role of DRIFTS in accelerating the development of high-performance and durable PCCs for next-generation energy solutions, offering methodologies and insights broadly applicable to a wide range of electrochemical energy conversion and storage technologies.

Diffuse Reflectance Infrared Fourier Transform Spe↗

Fourier transform infrared spectroscopy measurements of multi-phonon and free-carrier absorption in ZnO

Fourier transform infrared (FTIR) measurements were carried out on thin films and bulk single crystals of ZnO over a wide temperature range to study the free-carrier and multi-phonon infrared absorptions and the effects of hydrogen incorporation on these properties. Aluminum-doped ZnO thin films were deposited on quartz substrates using atomic-layer deposition (ALD) and sol–gel methods. Hall-effect measurements showed that the ALD films have a resistivity of ρ = 1.11 × 10 –3 Ω cm, three orders of magnitude lower than sol–gel films (ρ = 1.25 Ω cm). This result is consistent with the significant difference in their free-carrier absorption as revealed by FTIR spectra obtained at room temperature. By reducing the temperature to 80 K, the free carriers were frozen out, and their absorption spectrum was suppressed. From the FTIR measurements on ZnO single crystals that were grown by the chemical vapor transport method, we identified a shoulder around 3350 cm –1 and associated it with the presence of two or more hydrogen ions in a Zn vacancy. After reducing the hydrogen level in the crystal, the measurements revealed the multi-phonon absorption of ZnO in the range of 700–1200 cm –1 . Furthermore, this study shows that the multi-phonon absorption bands can be completely masked by the presence of a large concentration of hydrogen in the crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing the proton exchange kinetics of BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3− δ ceramic electrolyte by operando diffuse reflectance infrared Fourier transform spectroscopy

Proton exchange kinetics plays an important role in governing the performance of intermediate-temperature protonic ceramic electrolysis cells (PCECs) for hydrogen production. Our understanding of the nature of the surface hydration reaction at the single-cell level, however, remains very limited, hampering further efficiency improvements. Here, in this study, we developed a custom operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) platform that operates under high temperature and steam conditions with applied bias. Quantitative investigations of surface H 2 O/D 2 O isotope exchange in a BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3−δ (BZCYYb1711) protonic electrolyte-based single cell were conducted under different applied voltages using this DRIFTS platform, to gain molecular-level insight into hydration kinetics. The findings show that the application of an external voltage significantly enhances the surface proton exchange rate, decreasing the apparent activation energy from 29.1 kJ mol −1 at open-circuit voltage (OCV) to 6.8 kJ mol −1 at 1.3 V. In addition, distinct voltage-induced spectral shifts in O–D vibrations point to dynamic changes in surface hydration. These findings demonstrate a sensitive spectroscopic platform for probing interfacial proton processes and reveal strong electrochemical control over surface proton kinetics, offering new opportunities for probing electrolyte hydration behavior in PCECs.

36 - MATERIALS SCIENCE↗

Characterization of the surfaces of platinum/tin oxide based catalysts by Fourier Transform Infrared Spectroscopy (FTIR)

A Pt/SnO2 catalyst has been developed at NASA Langley that is effective for the oxidation of CO at room temperature (1). A mechanism has been proposed to explain the effectiveness of this catalyst (2), but most of the species involved in this mechanism have not been observed under actual catalytic conditions. A number of these species are potentially detectable by Fourier Transform Infrared Spectroscopy (FTIR), e.g., HOSnO sub x, HO sub y PtO sub z, Pt-CO, and SnHCO3. Therefore a preliminary investigation was conducted to determine what might be learned about this particular catalyst by transmission FTIR. The main advantage of FTIR for this work is that the catalyst can be examined under conditions similar to the actual catalytic conditions. This can be of critical importance since some surface species may exist only when the reaction gases are present. Another advantage of the infrared approach is that since vibrations are probed, subtle chemical details may be obtained. The main disadvantage of this approach is that FTIR is not nearly as sensitive as the Ultra High Vacuum (UHV) surface analytical techniques such as Auger, Electron Spectroscopy for Chemical Analysis (ESCA), Electron Energy Loss Spectroscopy (EELS), etc. Another problem is that the assignment of the observed infrared bands may be difficult.

Keiser, Joseph T.↗

Fourier Transform Infrared Spectroscopy

KSC's Analytical Laboratories branch provides Center-wide chemical analysis support for the identification of contaminants found in payloads, flight hardware, clean rooms, and processing facilities for programs such as Orion, and almost every payload launched from KSC including commercial operations. This is a common but very serious issue and there are stringent health and safety restrictions pertaining to foreign object debris and contamination in aerospace systems due to their extremely sensitive nature and potential to interface with the astronauts aboard the ISS. When contamination is discovered, such as fibers, particles, residues, etc., it is sampled and then analyzed to determine its identity. Fourier Transform Infrared spectroscopy (FTIR) is a critical component of this analysis.

FTIR↗

Measuring Thermal Emission Near Room Temperature Using Fourier-Transform Infrared Spectroscopy

Accurate characterization of thermal emitters can be challenging due to the presence of background thermal emission from components of the experimental setup and the surrounding environment. This is especially true for an emitter operating close to room temperature. Here, we explore the characterization of near-room-temperature thermal emitters using Fourier-transform infrared (FTIR) spectroscopy. We find that the thermal background arising from optical components placed between the beam splitter and the detector in an FTIR spectrometer appears as a “negative” contribution to the Fourier-transformed signal, leading to errors in thermal-emission measurements near room temperature. As a result, awareness of this contribution will help properly calibrate low-temperature thermal-emission measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Poison or Promoter? Investigating the Dual-Role of Carbon Monoxide in Pincer-Iridium-Based Alkane Dehydrogenation Systems via Operando Diffuse Reflectance Infrared Fourier Transform Spectroscopy

Pincer-ligated iridium complexes of the form [( R 4 PCP)IrL] ( R 4 PCP = κ 3 -C 6 H 3 -2,6-(XPR 2 ) 2 ; X = CH 2 , O; R = tBu, iPr) have previously been shown competent for acceptorless alkane dehydrogenation when supported on silica. It was observed by postcatalysis solid-state NMR that silica-tethered [(≡SiO- tBu 4 POCOP)Ir(C 2 H 4 )] (3-C 2 H 4 ) was converted fully to [(≡SiO- tBu 4 POCOP)Ir(CO)] (3-CO) at 300 °C. In this work, the characterization of species under dehydrogenation reaction conditions far from equilibrium between butane and butenes (approach to equilibrium Q/K eq = 0.3 at 300 °C) is performed with operando Diffuse Reflectance Infrared Fourier–Transform Spectroscopy (DRIFTS) to show the kinetics of species conversion from 3-C 2 H 4 to 3-CO. It is further found that [(≡SiO- tBu 4 POCOP)IrHCl] (3-HCl), a species considered to be a precatalyst for alkane dehydrogenation, is also fully converted to 3-CO. Here, a mechanism of decomposition is proposed that implicates surface silanol groups, while carbon monoxide acts as a “stabilizer” for the catalyst by promoting their reductive elimination and maintaining the complex in the I oxidation state.

02 PETROLEUM↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

Observation of Potential Contaminants in Processed Biomass Using Fourier Transform Infrared Spectroscopy

With rapidly increased interests in biomass, diverse chemical and biological processes have been applied for biomass utilization. Fourier transform infrared (FTIR) analysis has been used for characterizing different types of biomass and their products, including natural and processed biomass. During biomass treatments, some solvents and/or catalysts can be retained and contaminate biomass. In addition, contaminants can be generated by the decomposition of biomass components. Herein, we report FTIR analyses of a series of contaminants, such as various solvents, chemicals, enzymes, and possibly formed degradation by-products in the biomass conversion process along with poplar biomass. This information helps to prevent misunderstanding the FTIR analysis results of the processed biomass.

09 BIOMASS FUELS↗

In situ CF3 Detection in Low Pressure Inductive Discharges by Fourier Transform Infrared Spectroscopy

The detection of CF(x) (x=1-3) radicals in low pressure discharges using source gases such as CF4 and CHF3 is of importance to the understanding of their chemical structure and relevance in plasma based etching processes. These radicals are known to contribute to the formation of fluorocarbon polymer films, which affect the selectivity and anisotropy of etching. In this study, we present preliminary results of the quantitative measurement of trifluoromethyl radicals, CF3, in low pressure discharges. The discharge studied here is an inductively (transformer) coupled plasma (ICP) source in the GEC reference cell, operating on pure CF4 at pressures ranging from 10 - 100 mTorr, This plasma source generates higher electron number densities at lower operating pressures than obtainable with the parallel-plate capacitively coupled version of the GEC reference cell. Also, this expanded operating regime is more relevant to new generations of industrial plasma reactors being used by the microelectronics industry. Fourier transform infrared (FTIR) spectroscopy is employed to observe the absorption band of CF3 radicals in the electronic ground state X2Al in the region of 1233-1270/cm. The spectrometer is equipped with a high sensitivity HgCdTe (MCT) detector and has a fixed resolution of 0.125/cm. The CF3 concentrations are measured for a range of operating pressures and discharge power levels.

Kim, J. S.↗