A humidity-controlled fast integrated mobility spectrometer (HFIMS) for rapid measurements of particle hygroscopic growth

We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et al., 2017) combines the Fast Integrated Mobility Spectrometer (Kulkarni and Wang, 2006a, b) with laminar flow water condensation methodologies (Hering & Stolzenburg 2005; Spielman et al. 2017). Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1-Hz measurements of size distribution spanning a factor of ~3 in particle diameter, sufficient to cover the entire range of growth factor for atmopheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA) system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior, and further through measurements of ambient aerosols. Results show that HFIMS can reproduce, within 2 % the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 % and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001), and efflorescence relative humidity (43 %) was found to lie within the RH range of 41 % to 56 % reported in the literature. Ambient data indicate that HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than three minutes, which makes it about an order of magnitude faster than traditional HTDMA systems.

54 ENVIRONMENTAL SCIENCES↗

A Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid measurements of particle hygroscopic growth

We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et al., 2017) combines the Fast Integrated Mobility Spectrometer (Kulkarni and Wang, 2006a, b) with laminar flow water condensation methodologies (Hering and Stolzenburg, 2005; Spielman et al., 2017). Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1-Hz measurements of size distribution spanning a factor of ~ 3 in particle diameter, sufficient to cover the entire range of growth factor for atmospheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA) system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior, and further through measurements of ambient aerosols. Results show that HFIMS can reproduce, within 2 % the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 % and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001), and efflorescence relative humidity (43 %) was found to lie within the RH range of 41 % to 56 % reported in the literature. Ambient data indicate that HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than three minutes, which makes it about an order of magnitude faster than traditional HTDMA systems.

54 ENVIRONMENTAL SCIENCES↗

Bose-Einstein Condensates with Spin-Orbit Interaction

Motivated by recent experiments carried out by Spielman's group at NIST, we study a general scheme for generating families of gauge fields, spanning the scalar, spin-orbit, and non-Abelian regimes. The NIST experiments, which impart momentum to bosons while changing their spin state, can in principle realize all these. In the spin-orbit regime, we show that a Bose gas is a spinor condensate made up of two non-orthogonal dressed spin states carrying different momenta. As a result, its density shows a stripe structure with a contrast proportional to the overlap of the dressed states, which can be made very pronounced by adjusting the experimental parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polynomial time blackbox identity testers for depth-3 circuits : the field doesn't matter.

Let C be a depth-3 circuit with n variables, degree d and top fanin k (called {Sigma}{Pi}{Sigma}(k, d, n) circuits) over base field F. It is a major open problem to design a deterministic polynomial time blackbox algorithm that tests if C is identically zero. Klivans & Spielman (STOC 2001) observed that the problem is open even when k is a constant. This case has been subjected to a serious study over the past few years, starting from the work of Dvir & Shpilka (STOC 2005). We give the first polynomial time blackbox algorithm for this problem. Our algorithm runs in time poly(n)d{sup k}, regardless of the base field. The only field for which polynomial time algorithms were previously known is F = Q (Kayal & Saraf, FOCS 2009, and Saxena & Seshadhri, FOCS 2010). This is the first blackbox algorithm for depth-3 circuits that does not use the rank based approaches of Karnin & Shpilka (CCC 2008). We prove an important tool for the study of depth-3 identities. We design a blackbox polynomial time transformation that reduces the number of variables in a {Sigma}{Pi}{Sigma}(k, d, n) circuit to k variables, but preserves the identity structure. Polynomial identity testing (PIT) is a major open problem in theoretical computer science. The input is an arithmetic circuit that computes a polynomial p(x{sub 1}, x{sub 2},..., x{sub n}) over a base field F. We wish to check if p is the zero polynomial, or in other words, is identically zero. We may be provided with an explicit circuit, or may only have blackbox access. In the latter case, we can only evaluate the polynomial p at various domain points. The main goal is to devise a deterministic blackbox polynomial time algorithm for PIT.

99 GENERAL AND MISCELLANEOUS↗

Full Scale Evaluation of How Task-Based Overview Displays Impact Operator Workload and Situation Awareness When in Emergency Procedure Space

Control room modernization is critical to extending the life of the 99 operating commercial nuclear power plants (NPP) within the United States. However, due to the lack of evidence demonstrating the efficiency and effectiveness of recent candidate technologies, current NPP control rooms operate without the benefit of various newer technologies now available. As nuclear power plants begin to extend their licenses to continue operating for another 20 years, there is increased interest in modernizing the control room and supplementing the existing control boards with advanced technologies. As part of a series of studies investigating the benefits of advanced control room technologies, the researchers conducted an experimental study to observe the effect of Task-Based Overview Displays (TODs) on operator workload and situation awareness (SA) while completing typical operating scenarios. Researchers employed the Situation Awareness Rating Technique (SART) and the NASA Task Load Index (TLX) as construct measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

A fast integrated mobility spectrometer for rapid measurement of sub-micrometer aerosol size distribution, Part I: Design and model evaluation

This study discusses, a fast integrated mobility spectrometer (FIMS) was previously developed to characterize submicron aerosol size distributions at a frequency of 1 Hz and with high size resolution and counting statistics. However, the dynamic size range of the FIMS was limited to one decade in particle electrical mobility. It was proposed that the FIMS dynamic size range can be greatly increased by using a spatially varying electric field. This electric field creates regions with drastically different field strengths in the separator, such that particles of a wide diameter range can be simultaneously classified and subsequently measured. A FIMS incorporating this spatially varying electric field is developed. This paper describes the theoretical frame work and numerical simulations of the FIMS with extended dynamic size range, including the spatially varying electric field, particle trajectories, activation of separated particles in the condenser, and the transfer function, transmission efficiency, and mobility resolution. The influences of the particle Brownian motion on FIMS transfer function and mobility resolution are examined. The simulation results indicate that the FIMS incorporating the spatially varying electric field is capable of measuring aerosol size distribution from 8 to 600 nm with high time resolution. As a result, the experimental characterization of the FIMS is presented in an accompanying paper.

54 ENVIRONMENTAL SCIENCES↗

A fast integrated mobility spectrometer for rapid measurement of sub-micrometer aerosol size distribution, Part II: Experimental characterization

A Fast Integrated Mobility Spectrometer (FIMS) with a wide dynamic size range has been developed for rapid aerosol size distribution measurements. The design and model evaluation of the FIMS are presented in the preceding paper (Paper I), and this paper focuses on the experimental characterization of the FIMS. Monodisperse aerosol with diameter ranging from 8 to 600 nm was generated using Differential Mobility Analyzer (DMA), and was measured by the FIMS in parallel with a Condensation Particle Counter (CPC). The mean particle diameter measured by the FIMS is in good agreement with the DMA centroid diameter. Comparison of the particle concentrations measured by the FIMS and CPC indicates the FIMS detection efficiency is essentially 100% for particles with diameters of 8 nm or larger. For particles smaller than 20 nm or larger than 200 nm, FIMS transfer function and resolution can be well represented by the calculated ones based on simulated particle trajectories in the FIMS. For particles between 20 and 200 nm, the FIMS transfer function is boarder than the calculated, likely due to non-ideality of the electric field, including edge effects near the end of the electrode, which are not represented by the 2-D electric field used to simulate particle trajectories.

54 ENVIRONMENTAL SCIENCES↗

Conceptual design of a 15-TW pulsed-power accelerator for high-energy-density—physics experiments

We have developed a conceptual design of a 15-TW pulsed-power accelerator based on the linear-transformer-driver (LTD) architecture described by Stygar [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The driver will allow multiple, high-energy-density experiments per day in a university environment and, at the same time, will enable both fundamental and integrated experiments that are scalable to larger facilities. In this design, many individual energy storage units (bricks), each composed of two capacitors and one switch, directly drive the target load without additional pulse compression. Ten LTD modules in parallel drive the load. Each module consists of 16 LTD cavities connected in series, where each cavity is powered by 22 bricks connected in parallel. This design stores up to 2.75 MJ and delivers up to 15 TW in 100 ns to the constant-impedance, water-insulated radial transmission lines. The transmission lines in turn deliver a peak current as high as 12.5 MA to the physics load. To maximize its experimental value and flexibility, the accelerator is coupled to a modern, multibeam laser facility (four beams with up to 5 kJ in 10 ns and one beam with up to 2.6 kJ in 100 ps or less) that can provide auxiliary heating of the physics load. The lasers also enable advanced diagnostic techniques such as X-ray Thomson scattering and multiframe and three-dimensional radiography. The coupled accelerator-laser facility will be the first of its kind and be capable of conducting unprecedented high-energy-density–physics experiments.

47 OTHER INSTRUMENTATION↗

Environmental impact of solution pH on the formation and migration of iron colloids in deep subsurface energy systems

Deep subsurface stimulation processes often promote fluid-rock interactions that can lead to the formation of small colloidal particles that are suspected to migrate through the rock matrix, partially or fully clog pores and microfractures, and promote the mobilization of contaminants. Thus, the goal of this work is to understand the geochemical changes of the host rock in response to reservoir stimulation that promote the formation and migration of colloids. Two different carbonate-rich shales were exposed to different solution pHs (pH = 2 and 7). In this study, iron and other mineral transformations at the shale-fluid interface were first characterized by synchrotron-based XRF mapping. Then, colloids that were able to migrate from the shale into the bulk fluid were characterized by synchrotron-based extended X-ray absorption structure (EXAFS), scanning electron microscopy (SEM), and single-particle inductively coupled plasma time-of-flight mass spectrometry (sp-icpTOF-MS). When exposed to the pH = 2 solution, extensive mineral dissolution and secondary precipitation was observed; iron-(oxyhydr)oxide colloids colocated with silicates were observed by SEM at the fluid-shale interfaces, and the mobilization of chromium and nickel with these iron colloids into the bulk fluid was detected by sp-icpTOF-MS. Iron EXAFS spectra of the solution at the shale-fluid interface suggests the rapid (within minutes) formation of ferrihydrite-like nanoparticles. Thus, we demonstrate that the pH neutralization promotes the mobilization of existing silicate minerals and the rapid formation of new iron colloids. These Fe colloids have the potential to migrate through the shale matrix and mobilize other heavy metals (such as Cr and Ni, in this study) and impacting groundwater quality, as well produced waters from these hydraulic fracturing operations.

54 ENVIRONMENTAL SCIENCES↗

Organic colloid composition in variable-redox porewaters within a mountainous floodplain

Redox gradients, often driven by changes in sediment moisture levels in porous, heterogeneous groundwater systems, create dynamic conditions that may promote the production and transport of colloids within natural waters. While much research has focused on the inorganic composition of colloids, the organic composition remains less well understood. Organic matter (OM) in colloids may associate with minerals, complex metal ions, and serve as an electron donor for microbial respiration; therefore, its composition is of high interest. We examined the composition of porewater OM along a redox gradient in a riparian soil located along the Slate River in Crested Butte, Colorado, USA as a function of depth (90, 130, 200, and 350 cm below ground surface). All depths were oxic to suboxic, except 200 cm, where the products of iron and sulfate reduction were observed concomitant with an increase in dissolved and/or colloidal OM, pH, alkalinity, and conductivity. We investigated the composition of porewater using correlated scanning transmission X-ray microscopy and transmission electron microscopy. We observed a change in the OM chemistry from carboxylate-rich at the 200 cm depth (where it was also enmeshed with non-crystalline iron) to phenol- and substituted-aromatic-rich at other depths. Radiocarbon dating revealed carbon in porewater at 200 cm was younger than depths above and below. Soil porewater can flow down into the underlaying gravel bed during baseflow conditions, thus we speculate whether riparian porewater could transport iron- and carboxylate-rich organic colloids into surrounding surface waters through the gravel bed conduit.

Alpine floodplain↗

Impact of Acid–Base Stimulation Sequence on Mineral Stability for Tight/Impermeable Unconventional Carbonate-Rich Rocks: A Delaware Basin Case Study

We report mineral precipitation due to reactions with injected fluids during unconventional fracture stimulation is a well-recognized problem. The goal of this study is to evaluate secondary mineral precipitation and permeability attenuation under chemical injection scenarios specific to the Delaware basin. Whole cylindrical cores (2.54 cm diameter and 2.54 cm height) and ground shale (150–250 μm) from the carbonate-rich Bone Spring Formation, Delaware Basin TX (Leonardian), were reacted at 80 °C and 85 bar using a hydraulic fracturing fluid (HFF) recipe and an injection sequence typical of the Delaware Basin. The reacted shales and solutions were analyzed using a variety of laboratory- and synchrotron-based techniques to characterize both the chemical and spatial distributions of secondary mineral precipitation and identify changes in permeability and mineralogy. This carbonate-rich shale (>84% calcite) rapidly neutralized the acidic HFF. Synchrotron-based X-ray fluorescence mapping coupled with X-ray absorption spectroscopy (both bulk and micro) showed that most of the iron was in an oxidized form prior to exposure to HFF and that almost all iron(II) became fully oxidized after the reaction. Scanning electron microscopy images of the ground shale samples primarily identified iron(oxyhydr)oxide microcrystals on grain surfaces. A few small isolated iron-rich areas also contained sulfur, suggesting that some pyrite was preserved when isolated within a calcite crystal but that most was oxidized. The rapid neutralization of the acid spearhead in these carbonate-rich samples demonstrates that the acid spearhead is useful for initiating fractures in extremely calcite-rich rocks but does little to enhance rock permeability. This suggests that the impact of the acid spearhead is significantly smaller for carbonate-rich shales compared to clay-rich shales, which has broad implications for acidizing in carbonate-rich shale formations and iron transformations within these shales.

58 GEOSCIENCES↗

A Critical Review of the Physicochemical Impacts of Water Chemistry on Shale in Hydraulic Fracturing Systems

Hydraulic fracturing of unconventional hydrocarbon resources involves the sequential injection of a high-pressure, particle-laden fluid with varying pH’s to make commercial production viable in low permeability rocks. This process both requires and produces extraordinary volumes of water. The water used for hydraulic fracturing is typically fresh, whereas “flowback” water is typically saline with a variety of additives which complicate safe disposal. As production operations continue to expand, there is an increasing interest in treating and reusing this high-salinity produced water for further fracturing. Here in this paper we review the relevant transport and geochemical properties of shales, and critically analyze the impact of water chemistry (including produced water) on these properties. We discuss five major geochemical mechanisms that are prominently involved in the temporal and spatial evolution of fractures during the stimulation and production phase: shale softening, mineral dissolution, mineral precipitation, fines migration, and wettability alteration. A higher salinity fluid creates both benefits and complications in controlling these mechanisms. For example, higher salinity fluid inhibits clay dispersion, but simultaneously requires more additives to achieve appropriate viscosity for proppant emplacement. In total this review highlights the nuances of enhanced hydrogeochemical shale stimulation in relation to the choice of fracturing fluid chemistry.

54 ENVIRONMENTAL SCIENCES↗

Geochemical Modeling of Celestite (SrSO 4 ) Precipitation and Reactive Transport in Shales

Celestite (SrSO 4 ) precipitation is a prevalent example of secondary sulfate mineral scaling issues in hydraulic fracturing systems, particularly in basins where large concentrations of naturally occurring strontium are present. Herein, we present a validated and flexible geochemical model capable of predicting celestite formation under such unconventional environments. Simulations were built using CrunchFlow and guided by experimental data derived from batch reactors. These data allowed the constraint of key kinetic and thermodynamic parameters for celestite precipitation under relevant synthetic hydraulic fracturing fluid conditions. Effects of ionic strength, saturation index, and the presence of additives were considered in the combined experimental and modeling construction. This geochemical model was then expanded into a more complex system where interactions between hydraulic fracturing fluids and shale rocks were allowed to occur subject to diffusive transport. We find that the carbonate content of a given shale and the presence of persulfate breaker in the system strongly impact the location and extent of celestite formation. The results of this study provide a novel multicomponent reactive transport model that may be used to guide future experimental design in the pursuit of celestite and other sulfate mineral scale mitigation under extreme conditions typical of hydraulic fracturing in shale formations.

54 ENVIRONMENTAL SCIENCES↗