The Algorithm for MODIS Wavelength On-Orbit Calibration using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didyrnium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, beta (half angle between the incident and diffractive beams) and theta(sub ff) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing. The response of the MODIS bands to the SRCA output is also normalized by the reference SIPD signal to eliminate the effect of the source spectrum. That response differs from what is measured by MODIS using the Spectral Measurements Assembly (SpMA), a laboratory double-monochromator, due to the wider slit width of the SRCA. The SRCA slit function, calculated using measurements by the SPMA and the SRCA at the same MODIS temperature, will be used to recover the MODIS spectral response using the SRCA data measured on-orbit.

Montgomery, Harry↗

Measuring Crosstalk in MODIS Spectral Bands On-orbit Using the SRCA

Near-identical MODIS instruments launched on-board the Terra and Aqua spacecraft in 1999 and 2002, respectively. Each MODIS instrument has36 spectral bands covering 0.41 to 14.2μm mounted among four focal plane assemblies, along with a series of on-board calibrators (OBCs) used to characterize the instrument performance on-orbit. One such OBC is the Spectro-radiometric Calibration Assembly (SRCA), which is a multi-function calibrator, able to provide calibration sources to measure spatial, spectral, or radiometric properties of the MODIS bands depending on its configuration. The MODIS instrument performance, including measurements of the signal cross-contamination (crosstalk) between bands, was measured on-orbit during early-mission characterization for both instruments. This crosstalk test used the SRCA in its spatial mode while utilizing the thin slit, which is normally used for spectral calibrations. A similar crosstalk test was recently performed for Terra MODIS. Since the Terra safe mode event in 2016, the PVLWIR bands specifically (6.7-9.7μm) have shown increased influence from crosstalk. The process involved in preparing and performing this crosstalk test is included in this work, as well as the findings from the recent and previous SRCA-based crosstalk characterizations.

MODIS↗

The Algorithm for MODIS Wavelength On-Orbit Calibration Using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didymium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, Beta (half angle between the incident and diffractive beams) and Theta(sub off) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing.

Montgomery, Harry↗

On-Orbit Lunar Modulation Transfer Function Measurements for the Moderate Resolution Imaging Spectroradiometer

Spatial quality of an imaging sensor can be estimated by evaluating its modulation transfer function (MTF) from many different sources such as a sharp edge, a pulse target, or bar patterns with different spatial frequencies. These well-defined targets are frequently used for prelaunch laboratory tests, providing very reliable and accurate MTF measurements. A laboratory-quality edge input source was included in the spatial-mode operation of the Spectroradiometric Calibration Assembly (SRCA), which is one of the onboard calibrators of the Moderate Resolution Imaging Spectroradiometer (MODIS). Since not all imaging satellites have such an instrument, SRCA MTF estimations can be used as a reference for an on-orbit lunar MTF algorithm and results. In this paper, the prelaunch spatial quality characterization process from the Integrated Alignment Collimator and SRCA is briefly discussed. Based on prelaunch MTF calibration using the SRCA, a lunar MTF algorithm is developed and applied to the lifetime on-orbit Terra and Aqua MODIS lunar collections. In each lunar collection, multiple scan-directionMoon-to-background transition profiles are aligned by the subpixel edge locations from a parametric Fermi function fit. Corresponding accumulated edge profiles are filtered and interpolated to obtain the edge spread function (ESF). The MTF is calculated by applying a Fourier transformation on the line spread function through a simple differentiation of the ESF. The lifetime lunar MTF results are analyzed and filtered by a relationship with the Sun-Earth-MODIS angle. Finally, the filtered lunarMTF values are compared to the SRCA MTF results. This comparison provides the level of accuracy for on-orbit MTF estimations validated through prelaunch SRCA measurements. The lunar MTF values had larger uncertainty than the SRCA MTF results; however, the ratio mean of lunarMTF fit and SRCA MTF values is within 2% in the 250- and 500-m bands. Based on the MTF measurement uncertainty range, the suggested lunar MTF algorithm can be applied to any on-orbit imaging sensor with lunar calibration capability.

Choi, Taeyong↗

Comparison of Terra and Aqua MODIS VIS Bands On-Orbit Response

The Moderate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with a total of 490 detectors, covering spectral regions in the visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). MODIS is a cross-track scanning radiometer which collects data using a rotating scan mirror (both sides) over a wide range of scan angles. The VIS, NIR, and SWIR bands (bands 1-19 and 26) make measurements of daytime surface reflected radiances, thus are referred to as the reflective solar bands (RSB). MODIS was built with a complete set of on-board calibrators, capable of providing radiometric, spatial, and spectral calibration and characterization during its entire mission. The RSB on-orbit calibration is primarily provided using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD and SDSM calibration system is operated on a regular (weekly to bi-weekly) basis. The spectro-radiometric calibration assembly (SRCA) is another on-hoard calibrator that also provides RSB radiometric calibration support. For this purpose, the SRCA is operated in a radiometric mode on a monthly basis. A complete SRCA radiometric calibration is performed using different lamp configurations, or different radiance levels, to cover the range of RSB gain. Two additional SRCA modes with slightly different configurations are designed and operated for sensor on-orbit spectral and spatial characterization. In addition to its on-hoard calibrators, each MODIS makes monthly lunar observations to monitor RSB radiometric calibration stability. The MODIS lunar observations are made through its space view (SV) port at nearly the same lunar phase angles via spacecraft roll maneuvers. The SD, SRCA, and lunar measurements are made at different scan angles and data samples are collected for all spectral bands and detectors using both sides of the scan minor. Since launch, Terra and Aqua MODIS have operated successfully for more than 8 years and 6 years, respectively. Many SD/SDSM, SRCA, and lunar observations have been made by each instrument and used to derive RSB on-orbit calibration parameters, enabling corrections for sensor response changes and changes of the response versus scan angle (RVS). In general, the RSB calibration parameters are updated regularly into the MODIS Level 1B (LIB) code in support of continuous data processing for all MODIS science data products. This paper provides a brief description of MODIS RSB calibration methodologies and approaches, and summarizes on-orbit changes of their responses (gains), particularly for the VIS spectral bands.

Xiong, Xiaoxiong↗

Twenty Years of Terra MODIS Spatial Performance Using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the NASA’s Earth Observing System Terra satellite has continued successful Earth-sensing operations for over 20 years. To aid in its mission in providing calibrated science data to the worldwide user community, the MODIS instrument is equipped with several on-board calibrators designed to measure changes in the instrument response over time. One such calibrator is the Spectro-Radiometric Calibration Assembly (SRCA), which can provide a source signal for radiometric, spectral, or spatial characterization. When commanded into its spatial calibration mode, the SRCA is able to produce light across the MODIS band spectral range (0.412μm to 14.2μm) at a variety of signal levels thanks to several internal halogen lamps, an IR glow bar, and a neutral density filter. This signal, used in combination with commanded sub-sample measurements of the MODIS detectors, provides a basis for determining changes in the spatial performance of the MODIS spectral bands. This work summarizes the spatial calibration process using the SRCA and presents 20 years of Terra MODIS spatial performance characterized through co-registration between MODIS bands, detectors, and focal plane assemblies. Results from pre-launch testing using the Integration and Alignment Collimator and the SRCA are incorporated in the history of the Terra MODIS mission-long spatial performance. We also note modifications to the spatial characterization methodology brought on by changes to the SRCA’s operational configuration and changes to the MODIS spectral band performance, particularly after the recovery from the safe-mode event in February 2016. Results are compared against the MODIS design specifications.

MODIS↗

Results and Lessons from a Decade of Terra MODIS On-Orbit Spectral Characterization

Since its launch in December 1999, the NASA EOS Terra MODIS has successfully operated for more than a decade. MODIS makes observations in 36 spectral bands from visible (VIS) to longwave infrared (LWIR) and at three nadir spatial resolutions: 250m (2 bands), 500m (5 bands), and 1km (29 bands). In addition to its on-board calibrators designed for the radiometric calibration, MODIS was built with a unique device, called the spectro-radiometric calibration assembly (SRCA). It can be configured in three different modes: radiometric, spatial, and spectral. When it is operated in the spectral modes, the SRCA can monitor changes in Sensor spectral performance for the VIS and near-infrared (NIR) spectral bands. For more than 10 years, the SRCA operation has continued to provide valuable information for MODIS on-orbit spectral performance. This paper briefly describes SRCA on-orbit operation and calibration activities; it presents decade-long spectral characterization results for Terra MODIS VIS and NIR spectral bands in terms of chances in their center wavelengths (CW) and bandwidths (BW). It is shown that the SRCA on-orbit wavelength calibration capability remains satisfactory. For most spectral bands, the changes in CW and BW are less than 0.5 and 1 nm, respectively. Results and lessons from Terra MODIS on-orbit spectral characterization have and will continue to benefit its successor, Aqua MODIS, and other future missions.

Xiong, X.↗

MODIS On-orbit Spectral Calibration for the Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) makes observations in 36 spectral bands with wavelengths from 0.41 to 14.5 microns. The bands with center wavelengths below 2.2 microns are referred as the reflective solar bands (RSB) with their radiometric calibration performed by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). This paper focuses on the MODIS spectral calibration performed by its unique on-board calibrator (OBC): the Spectro-Radiometric Calibration Assembly (SRCA). When operated in the spectral mode, the SRCA acts as a monochromator with internal spherical integration source (SIS) that measures the spectral responses for all the reflective solar bands. A wavelength calibrator, a didymium filter with known spectral profile, is utilized to calibrate the wavelength scale for the grating positions during each SRCA spectral calibration activity. The capability of self-wavelength calibration allows the SRCA to track the center wavelength shifts and to monitor the spectral response changes throughout the instruments lifetime. The MODIS spectral calibration, same for both Terra and Aqua missions, is performed every three months on-orbit. An overview of MODIS spectral characterization approach and a summary of the on-orbit results will be presented in this paper.

Xiong, X.↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

Status of MODIS Spatial and Spectral Characterization and Performance

Since launch, both Terra and Aqua MODIS instruments have continued to operate and make measurements of the earth's top of atmospheric (TOA) radiances and reflectance. MODIS collects data in 36 spectral bands covering wavelengths from 0.41 to 14.4 microns. These spectral bands and detectors are located on four focal plane assemblies (FPAs). MODIS on-board calibrators (OBC) include a spectro-radiometric calibration assembly (SRCA), which was designed to characterize and monitor sensor spatial and spectral performance, such as on-orbit changes in the band-to-band registration (BBR), modulation transfer function (MTF), spectral band center wavelengths (CW) and bandwidths (BW). In this paper, we provide a status update of MODIS spatial and spectral characterization and performance, following a brief description of SRCA functions and on-orbit calibration activities. Sensor spatial and spectral performance parameters derived from SRCA measurements are introduced and discussed. Results show that on-orbit spatial performance has been very stable for both Terra and Aqua MODIS instruments. The large BBR shifts in Aqua MODIS, an issue identified pre-launch, have remained the same over its entire mission. On-orbit changes in CW and BW are less than 0.5 nm and 1 nm, respectively, for most VIS/NIR spectral bands of both instruments.

Link, Daniel↗

An Overview of MODIS On-orbit Operation, Calibration, and Lessons

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated onboard the Terra and Aqua spacecraft for more than II years and 9 years since their launch in December 1999 and May 2002, respectively. MODIS is a key instrument for the NASA's Earth Observing System (EOS) missions. MODIS observations have produced an unprecedented amount and a broad range of data products and significantly benefited the science and user community. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS) on-board the NPOESS Preparatory Project (NPP) spacecraft, is currently scheduled for launch in late October, 2011. The NPP serves as a bridge mission between EOS and the Joint Polar Satellite System (JPSS). MODIS collects data in 36 spectral bands, covering spectral regions from visible (VIS) to long-wave infrared (L WIR), and at three different spatial resolutions. Because of its stringent design requirements, MODIS was built with a complete set of onboard calibrators, including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. Except for tbe SRCA, VIlRS carries the same set of onboard calibrators as MODIS. The SD/SDSM system is used together to calibrate tbe reflective solar bands (RSB). The BB is designed for the thermal emissive bands (TEB) calibration. Similar to Terra and Aqua MODIS, VIlRS will also make regular lunar observations to monitor RSB radiometric calibration stability. In this paper, we provide an overview of MODIS on-orbit operation and calibration activities and present issues identified and lessons learned from mission-long instrument operations and implementation of various calibration and characterization strategies. Examples of both Terra and Aqua MODIS instrument on-orbit performance, including their similarities and unique characteristics, are discussed in tbe context of what might be expected from and benefited to tbe NPP VIlRS operation and calibration. It is anticipated that MODIS experience and lessons will also provide valuable information for other earth observing missions/sensors.

Xiong, Jack↗

MODIS. Volume 2: MODIS level 1 geolocation, characterization and calibration algorithm theoretical basis document, version 1

The EOS Moderate Resolution Imaging Spectrometer (MODIS) is being developed by NASA for flight on the Earth Observing System (EOS) series of satellites, the first of which (EOS-AM-1) is scheduled for launch in 1998. This document describes the algorithms and their theoretical basis for the MODIS Level 1B characterization, calibration, and geolocation algorithms which must produce radiometrically, spectrally, and spatially calibrated data with sufficient accuracy so that Global change research programs can detect minute changes in biogeophysical parameters. The document first describes the geolocation algorithm which determines geodetic latitude, longitude, and elevation of each MODIS pixel and the determination of geometric parameters for each observation (satellite zenith angle, satellite azimuth, range to the satellite, solar zenith angle, and solar azimuth). Next, the utilization of the MODIS onboard calibration sources, which consist of the Spectroradiometric Calibration Assembly (SRCA), Solar Diffuser (SD), Solar Diffuser Stability Monitor (SDSM), and the Blackbody (BB), is treated. Characterization of these sources and integration of measurements into the calibration process is described. Finally, the use of external sources, including the Moon, instrumented sites on the Earth (called vicarious calibration), and unsupervised normalization sites having invariant reflectance and emissive properties is treated. Finally, algorithms for generating utility masks needed for scene-based calibration are discussed. Eight appendices are provided, covering instrument design and additional algorithm details.

Barker, John L.↗

On-Orbit Performance of MODIS On-Board Calibrators

The Terra MODIS (Moderate Resolution Imaging Spectroradiometer) was launched on December 18, 1999 and acquired the first scene data on February 24, 2000. It has 36 spectral bands covering spectral range from 0.41 to 14.2 microns and provides spatial resolutions of 250 (2 bands), 500 (5 bands), and 1000 m at Nadir. The instrument on-orbit calibration and characterization are determined and monitored through the use of a number of on-board calibrators (OBC). Radiometric calibration for the reflective solar bands (B1-B19, B26), from VIS (visible) to SWIR (short wavelength infrared) (0.41 to 2.1 microns), uses a Spectralon (tm) solar diffuser (SD) and a solar diffuser stability monitor (SDSM). For the thermal emissive bands (B20-B25, B27-B36), from MWIR (medium wavelength infrared) to LWIR (long wavelength infrared) (3.75 to 14.2 micron), a V-grooved flat panel blackbody is used. The instrument spectral for the VIS to SWIR bands and spatial co-registration characterizations for all bands are monitored on-orbit by the spectral radiometric calibration assembly (SRCA). In this report, we discuss the application and performance of the key MODIS on-board calibrators and their impacts on the instrument system calibration and characterization.

Xiong, X.↗

MODIS In-flight Calibration Methodologies

MODIS is a key instrument for the NASA's Earth Observing System (EOS) currently operating on the Terra spacecraft launched in December 1999 and Aqua spacecraft launched in May 2002. It is a cross-track scanning radiometer, making measurements over a wide field of view in 36 spectral bands with wavelengths from 0.41 to 14.5 micrometers and providing calibrated data products for science and research communities in their studies of the Earth s system of land, oceans, and atmosphere. A complete suite of on-board calibrators (OBC) have been designed for the instruments in-flight calibration and characterization, including a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system for the radiometric calibration of the 20 reflective solar bands (RSB), a blackbody (BB) for the radiometric calibration of the 16 thermal emissive bands (TEB), and a spectro-radiometric calibration assembly (SRCA) for the spatial (all bands) and spectral (RSB only) characterization. This paper discusses MODIS in-flight Cali bration methodologies of using its on-board calibrators. Challenging issues and examples of tracking and correcting instrument on-orbit response changes are presented, including SD degradation (20% at 412nm, 12% at 466nm, and 7% at 530nm over four and a half years) and response versus scan angle changes (10%, 4%, and 1% differences between beginning of the scan and end of the scan at 412nm, 466nm, and 530nm) in the VIS spectral region. Current instrument performance and lessons learned are also provided.

Xiong, X.↗

An Overview of Lunar Calibration and Characterization for the EOS Terra and Aqua MODIS

The Moon can be used as a stable source for Earth-observing sensors on-orbit radiometric and spatial stability monitoring in the VIS and NIR spectral regions. It can also serve as a calibration transfer vehicle among multiple sensors. Nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODE) have been operating on-board the NASA's Earth Observing System (EOS) Terra and Aqua satellites since their launches in December 1999 and May 2002, respectively. Terra and Aqua MODIS each make observations in 36 spectral bands covering the spectral range from 0.41 to 14.5 microns and are calibrated on-orbit by a set of on-board calibrations (OBCs) including: 1) a solar diffuser (SD), 2) a solar diffuser stability monitor (SDSM), 3) a blackbody (BB), and 4) a spectro-radiometric calibration assembly (SRCA). In addition to fully utilizing the OBCs, the Moon has been used extensively by both Terra and Aqua MODIS to support their on-orbit calibration and characterization. A 4 This paper provides an overview of applications of lunar calibration and characterization from the MODIS perspective, including monitoring radiometric calibration stability for the reflective solar bands (RSBs), tracking changes of the sensors response versus scan-angle (RVS), examining the sensors spatial performance , and characterizing optical leaks and electronic crosstalk among different spectral bands and detectors. On-orbit calibration consistency between the two MODIS instruments is also addressed. Based on the existing on-orbit time series of the Terra and Aqua MODIS lunar observations, the radiometric difference between the two sensors is less than +/-1% for the RSBs. This method provides a powerful means of performing calibration comparisons among Earth-observing sensors and assures consistent data and science products for the long-term studies of climate and environmental changes.

Xiong, X.↗

MODIS On-orbit Calibration: Key Issues and Approaches

MODIS, one of the key instruments for the NASA's Earth Observing System (EOS), is currently operating on both the Terra and Aqua spacecraft making continuous observations in 36 spectral bands from 0.4 to 14.4 micrometers. A complete suite of on-board calibrators (OBC) have been designed for the instruments' on-orbit calibration and characterization, including a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system for the radiometric calibration of the 20 reflective solar bands (RSB), a blackbody (BB) for the radiometric calibration of the 16 thermal emissive bands (TEZB), and a spectro-radiometric calibration assembly (SRCA) for the sensors' spatial and spectral characterization. The task of continuously performing high quality on-orbit calibration and characterization of all 36 spectral bands with a total of 490 detectors located on four focal plane assemblies is extremely challenging. The use of a large two-sided paddle wheel scan mirror with a +/- 55 deg scan angle range and a retractable pinhole attenuation screen in front of the SD panel for calibrating the high gain bands have resulted in additional unanticipated complexity. In this paper, we describe some of the key issues in the Terra and Aqua MODIS on-orbit calibration and characterization, and discuss the methods developed to solve these problems or to reduce their impact on the Level 1B calibration algorithms. Instrument performance and current issues are also presented.

Xiong, Xian-Xiong↗

Calibration and Characterization of the NASA EOS Terra and Aqua MODIS Instruments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is operating on both of the Terra and Aqua missions within the NASA Earth Observing System (EOS). The Terra MODIS instrument began taking observations in February 2000 and the Aqua MODIS instrument began taking observations in June of 2002 and both continue to operate successfully up to the present time. The MODIS instrument scans the entire Earth every 24 hours at nominal spatial resolutions between 250 and 1000 meters. It has 36 spectral bands spanning the electromagnetic spectrum from the visible wavelengths mar 400 micrometers to the emissive thermal infrared wavelengths at 15 micrometers. The MODIS instruments produce approximately 40 geophysical products devoted to observing land, ocean, and atmospheric processes and trends. To meet the scientific objectives associated with the NASA Earth sciences efforts the MODIS instruments must be and have been carefully calibrated and the performance characterized to meet specifications and goals such as five percent radiance and two percent relative to the sun accuracy in the twenty bands providing reflected solar radiation observations and one percent radiance accuracy in the sixteen bands observing in the thermal infrared. Over the time spanning instrument development and the pre-launch calibration and characterization of the instrument through the years of operation in space, the performance of the MODIS instruments have changed in multiple ways and appropriate adjustments made in relevant algorithms and look-up tables necessary to produce observations that meet the scientific objectives and requirements. The changes have been quantified and accounted for through careful use of on-board calibration devices such as the Spectro-Radiometric Calibration Assembly (SRCA), the Solar Diffuser (SD) and its companion Solar Diffuser Stability Monitor (SDSM), deep-space and lunar observations, and calibration targets on the Earth's surface. The strictest and most difficult challenges have come in trying to meet the requirements for observing Ocean color and related ocean biology processes over time and space. Overall the MODIS observations have been very successful in providing valuable scientific and applications results. The essential capabilities of MODIS are to be provided in the future by the Visible and Infrared Imaging Radiometer Suite (VIIRS) on the National Polar Orbiting Environmental Satellite Series (NPOESS).

Salomonson, Vincent V.↗

An Overview of MODIS Calibration and Characterization

The MODerate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for the NASA s Earth Observing System (EOS). It is currently operating on both EOS Terra and Aqua satellites. The MODIS is a major advance over its heritage sensors in terms of its spectral, spatial, and temporal resolutions with frequent global observations and a broad range of science applications. There are 20 reflective solar bands (RSB) with center wavelengths ranging from 0.41 to 2.l microns and 16 thermal emissive bands (TEB) from 3.7 to 14.4 microns. The absolute radiometric accuracy requirements (lsigma) at the typical spectral radiance levels are plus or minus 2% for the RSB reflectance factors and plus or minus 5% for the RSB radiance products. With few exceptions, the TEB requirements are plus or minus 1%. To verify that the instruments met their specified design requirements both Terra and Aqua MODIS underwent extensive pre-launch calibration and characterization at various levels, including system-level thermal vacuum testing. On-orbit calibration and characterization are performed by the on-board calibrators: a solar diffuser (SD) and a solar diffuser stability monitor (SDSM), a V-groove flat panel blackbody (BB), and a spectro-radiometric calibration assembly (SRCA). In this paper, we present an overview of MODIS calibration and characterization activities, methodologies, and lessons learned from pre-launch testing and on-orbit operations. Key issues to be discussed include our on-orbit efforts of monitoring detectors noise characterization, tracking solar diffuser and optics degradation, and updating sensor s response versus scan-angle. The MODIS experience has provided invaluable lessons that are being used in designing and testing the Visible Infrared Imaging Radiometer Suite (VIIRS), a direct follow-on to the MODIS that will be flown on the National Polar-Orbit Operational Environmental Satellite System (NPOESS) missions.

Xiong, X.↗