Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stand-off elemental analyses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development and Testing of Laser-induced Breakdown Spectroscopy for the Mars Rover Program: Elemental Analyses at Stand-Off Distances

One of the most fundamental pieces of information about any planetary body is the elemental composition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks to which direct contact is possible. These in- situ analyses require that the lander or rover be in contact with the sample. In addition to in-situ instrumentation, the present generation of rovers carry instruments that operate at stand-off distances. The Mini-TES is an example of a stand-off instrument on the MER rovers. Other examples for future missions include infrared point spectrometers and microscopic-imagers that can operate at a distance. The main advantage of such types of analyses is obvious: the sensing element does not need to be in contact or even adjacent to the target sample. This opens up new sensing capabilities. For example, targets that cannot be reached by a rover due to impassable terrain or targets positioned on a cliff face can now be accessed using stand-off analysis. In addition, the duty cycle of stand-off analysis can be much greater than that provided by in-situ measurements because the stand-off analysis probe can be aimed rapidly at different features of interest eliminating the need for the rover to actually move to the target. Over the past five years we have been developing a stand-off method of elemental analysis based on atomic emission spectroscopy called laser-induced breakdown spectroscopy (LIBS). A laser-produced spark vaporizes and excites the target material, the elements of which emit at characteristic wavelengths. Using this method, material can be analyzed from within a radius of several tens of meters from the instrument platform. A relatively large area can therefore be sampled from a simple lander without requiring a rover or sampling arms. The placement of such an instrument on a rover would allow the sampling of locations distant from the landing site. Here we give a description of the LIBS method and its advantages. We discuss recent work on determining its characteristics for Mars exploration, including accuracy, detection limits, and suitability for determining the presence of water ice and hydrated minerals. We also give a description of prototype instruments we have tested in field settings.

D A Cremers↗

Multivariate Methods for Prediction of Geologic Sample Composition with Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) uses pulses of laser light to ablate a material from the surface of a sample and produce an expanding plasma. The optical emission from the plasma produces a spectrum which can be used to classify target materials and estimate their composition. The ChemCam instrument on the Mars Science Laboratory (MSL) mission will use LIBS to rapidly analyze targets remotely, allowing more resource- and time-intensive in-situ analyses to be reserved for targets of particular interest. ChemCam will also be used to analyze samples that are not reachable by the rover's in-situ instruments. Due to these tactical and scientific roles, it is important that ChemCam-derived sample compositions are as accurate as possible. We have compared the results of partial least squares (PLS), multilayer perceptron (MLP) artificial neural networks (ANNs), and cascade correlation (CC) ANNs to determine which technique yields better estimates of quantitative element abundances in rock and mineral samples. The number of hidden nodes in the MLP ANNs was optimized using a genetic algorithm. The influence of two data preprocessing techniques were also investigated: genetic algorithm feature selection and averaging the spectra for each training sample prior to training the PLS and ANN algorithms. We used a ChemCam-like laboratory stand-off LIBS system to collect spectra of 30 pressed powder geostandards and a diverse suite of 196 geologic slab samples of known bulk composition. We tested the performance of PLS and ANNs on a subset of these samples, choosing to focus on silicate rocks and minerals with a loss on ignition of less than 2 percent. This resulted in a set of 22 pressed powder geostandards and 80 geologic samples. Four of the geostandards were used as a validation set and 18 were used as the training set for the algorithms. We found that PLS typically resulted in the lowest average absolute error in its predictions, but that the optimized MLP ANN and the CC ANN often gave results comparable to PLS. Averaging the spectra for each training sample and/or using feature selection to choose a small subset of wavelengths to use for predictions gave mixed results, with degraded performance in some cases and similar or slightly improved performance in other cases. However, training time was significantly reduced for both PLS and ANN methods by implementing feature selection, making this a potentially appealing method for initial, rapid-turn-around analyses necessary for Chemcam's tactical role on MSL. Choice of training samples has a strong influence on the accuracy of predictions. We are currently investigating the use of clustering algorithms (e.g. k-means, neural gas, etc.) to identify training sets that are spectrally similar to the unknown samples that are being predicted, and therefore result in improved predictions

Morris, Richard↗

Field Exploration and Life Detection Sampling Through Planetary Analogue Sampling (FELDSPAR).

Exploration missions to Mars rely on rovers to perform analyses over small sampling areas; however, landing sites for these missions are selected based on large-scale, low-resolution remote data. The use of Earth analogue environments to estimate the multi-scale spatial distributions of key signatures of habitability can help ensure mission science goals are met. A main goal of FELDSPAR is to conduct field operations analogous to Mars sample return in its science, operations, and technology from landing site selection, to in-field sampling location selection, remote or stand-off analysis, in situ analysis, and home laboratory analysis. Lava fields and volcanic regions are relevant analogues to Martian landscapes due to desiccation, low nutrient availability, and temperature extremes. Operationally, many Icelandic lava fields are remote enough to require that field expeditions address several sampling constraints that are experienced in robotic exploration, including in situ and sample return missions. The Fimmvruhls lava field was formed by a basaltic effusive eruption associated with the 2010 Eyjafjallajkull eruption. Mlifellssandur is a recently deglaciated plain to the north of the Myrdalsjkull glacier. Holuhraun was formed by a 2014 fissure eruptions just north of the large Vatnajkull glacier. Dyngjusandur is an alluvial plain apparently kept barren by repeated mechanical weathering. Informed by our 2013 expedition, we collected samples in nested triangular grids every decade from the 10 cm scale to the 1 km scale (as permitted by the size of the site). Satellite imagery is available for older sites, and for Mlifellssandur, Holuhraun, and Dyngjusandur we obtained overhead imagery at 1 m to 200 m elevation. PanCam-style photographs were taken in the field by sampling personnel. In-field reflectance spectroscopy was also obtained with an ASD spectrometer in Dyngjusandur. All sites chosen were 'homogeneous' in apparent color, morphology, moisture, grain size, and reflectance spectra at all scales greater than 10 cm. Field lab assays were conducted to monitor microbial habitation, including ATP quantification, qPCR for fungal, bacterial, and archaeal DNA, and direct cell imaging using fluorescence microscopy. Home laboratory analyses include Raman spectroscopy and community sequencing. ATP appeared to be significantly more sensitive to small changes in sampling location than qPCR or fluorescence microscopy. Bacterial and archaeal DNA content were more consistent at the smaller scales, but similarly variable across more distant sites. Conversely, cell counts and fungal DNA content have significant local variation but appear relatively homogeneous over scales of 1 km. ATP, bacterial DNA, and archaeal DNA content were relatively well correlated at many spatial scales. While we have observed spatial variation at various scales and are beginning to observe how that variation fluctuates over time as biodiversity recovers after an eruption, we do not yet fully understand what parameters lead to the observed spatial variation. Home laboratory analyses will help us further understand the elemental and structural composition of the basaltic matrices, but further field analyses are vital for the understanding how temperature, moisture, incident radiation, and so forth influence the habitability of a microclimate.

Field↗