At least 19 records

A standard capsule design for structural material testing in the Advanced Test Reactor

Nuclear materials testing is commonly completed in various material test and research reactors throughout the world, including the Advanced Test Reactor (ATR), but the current capsule design, analysis, and fabrication process can take years to complete. To decrease the costs and time associated with materials testing, a standard capsule has been designed which houses various specimen geometries and allows irradiation in virtually any ATR test position. The standard capsule features locking end caps which connect and lock together to form the capsule stack, eliminating the need for a basket and maximizing the quantity of specimens which are contained within the capsule. A customizable internal gas gap provides thermal resistance between the specimens and reactor coolant, making specimen temperatures from approximately 370 to 1000 K achievable. The flexibility of the capsule design allows experimenters to choose irradiation positions based off desired neutron flux, with typical fluences per cycle ranging from 8.8x10 19 to 2.3x10 21 n/cm 2 , depending on experiment position. Here this paper presents and discusses the standard capsule design and analysis.

36 MATERIALS SCIENCE↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compact 1-4 and 10-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined in one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011 and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support the improvement of modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These two goals were combined in the AGR-3/4 irradiation, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a “fuel body”, in which the outer graphite ring included a floor and cap that fully enclosed the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compacts 8-4 and 7-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined into one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011, and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both to be focused on obtaining fission product transport data to support improvements in modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These goals were combined in the AGR-3/4 irradiation experiment, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a fuel body, in which the outer graphite ring included a floor and cap to fully enclose the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to obtain data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compacts 1-3, 4-3, 10-1, and 10-2

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined into one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011 and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support modeling improvement. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and post-irradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These two goals were combined in the AGR-3/4 irradiation, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a fuel body in which the outer graphite ring included a floor and cap that fully enclosed the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of Average Burnup in AGR-3/4 Compacts 1-4 and 7-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined in one test train for irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011, and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support the improvement of modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and post-irradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite. These two goals were combined in the AGR-3/4 irradiation, which consisted of 12 independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. Two capsule types were used: a standard capsule and a so-called fuel body, in which the outer graphite ring included a floor and cap that fully enclosed the fuel. The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from the matrix and graphite at accident temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The state of the art for neutron irradiation experiments from the perspective of the High Flux Isotope Reactor (HFIR)

Irradiation experiment campaigns are critical to advancing nuclear energy technologies by providing data on material performance under relevant radiation conditions. Successful irradiation experiments require integrated design efforts that balance technical goals with facility constraints. Here, this paper presents an expert-informed overview of irradiation experiment design at the High Flux Isotope Reactor. It addresses the nuclear materials research and irradiation experiment communities to guide them toward developing technically sound, facility-compatible campaigns. The High Flux Isotope Reactor is a multipurpose reactor supporting isotope production, neutron scattering, and materials testing. Its high, steady-state neutron flux is ideal for irradiation experiments, but successful execution demands coordinated thermal, structural, and reactor physics analyses. The paper outlines the complete development workflow from concept definition and design optimization to safety qualification and post-irradiation examination. Standardized capsule platforms are also discussed in terms of flexibility, specimen capacity, and thermal performance. Common failure modes such as unanticipated geometric variations, can impact temperature-dose profiles and compromise data reliability. Therefore, detailed thermal modeling and accurate as-built characterization are essential for meaningful post-irradiation data interpretation. Key recommendations include early engagement all stakeholders, clearly defined design expectations, and alignment of specimen geometries with post-irradiation examination capabilities. This approach reduces design iterations, enhances data quality, and supports more efficient use of irradiation resources. Strategic and well-planned irradiation testing not only improves individual campaign success but also accelerates the deployment of advanced nuclear technologies. By closing critical data gaps and reducing development risks, the nuclear materials community can more effectively contribute to the future of clean, resilient energy systems.

Experiments↗

Challenges and successes in establishing a multipurpose fuels and materials irradiation capsule [Slides]

This presentation discusses the challenges and success related to designing and fabricating multipurpose capsules for irradiation experiments for irradiation within the Advanced Test Reactor (ATR) to be presented at tje DEVICE-MTR irradiation experiment design working group meeting hosted by the Japanese Atomic Energy Agency (JAEA). The information herein is limited to the design of the capsules only and no programmatic information from any project supporting the design of the multipurpose capsule is discussed. The intent of the design team was establish a capsule design that could accommodate multiple different irradiation project needs for the irradiation of nuclear fuel and materials of interest in the nuclear field. The main points of the presentation are as follows: use of tin as a molten thermal bond material was selected for the fueled capsule design and was found to be inadequate as it would corrode the stainless steel at high temperatures, this capsule design has high sensitivity to manufacturing of the gas gap and control of the gas mixture, and the fueled capsule has experienced welding challenges with the inner capsule material 800H Incoloy.

42 ENGINEERING↗

Enhancing Post-Irradiation Examination (PIE) Efficiency with High-Throughput Experiments

Nuclear materials testing is essential for understanding changes in reactor environments, but traditional methods are costly and time-consuming. High-Throughput Experimentation (HTE) enables rapid screening and optimization of material properties by significantly increasing the number of specimens in the experiment. In this work, HTE methods were employed to irradiate novel materials at the Advanced Test Reactor (ATR) at Idaho National Laboratory. A total of 367 sub-sized tensile specimens were irradiated using the standard capsule design. To facilitate HTE, automated systems such as the Automated Mechanical Testing System were implemented for mechanical testing within hot cell environments, thereby reducing the need for manual interaction with hot cell manipulators and significantly lowering both the cost and duration of experiments. Digital image correlation (DIC) was used to measure displacement during mechanical testing, providing precise, non-contact measurement capabilities. The methodologies developed in this research will support the advancement of HTE techniques for future nuclear materials testing experiments at ATR. This approach allows for more efficient and cost-effective evaluation of new materials, ultimately leading to improved reactor performance, enhanced safety, and extended longevity within the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

AMMT Round Robin 316H HFIR Irradiation Test Matrix and Readiness for Insertion

The Round Robin 316H HFIR-2 irradiation campaign, conducted under the Advanced Materials and Manufacturing Technologies (AMMT) Program, is designed to evaluate the variability in irradiation response of laser powder bed fusion (LPBF) stainless steel (SS)-316H across multiple national laboratories, powder heats, and processing conditions, with comparison to wrought counterparts. A total of 11 materials are intended for irradiation in the High Flux Isotope Reactor (HFIR), targeting two irradiation temperatures (400°C and 600°C) and one level of irradiation damage (2 dpa). This irradiation campaign utilizes the standardized general tensile (GENTEN) capsule design to accommodate subsized tensile specimens of these materials. Thermal analyses were performed to ensure appropriate temperature control by design and uniformity within the capsules. All the capsules for this irradiation except one have been successfully assembled, welded, and tested and are ready for HFIR insertion. The last capsule requires re-build following a failed weld. All eight capsules are intended to be inserted in HFIR cycle 517, which is scheduled to start September 8, 2026. This report summarizes the design, material selection, and readiness for insertion of the capsules.

36 MATERIALS SCIENCE↗

Status memorandum on ORNL support of vendor irradiation capsule design and ASME irradiation code development and new ASTM test standard development activities

This report is in submission of completion of the Level 4 milestone number M4TG-24OR0501111 within the larger Advanced Reactor Technologies Gas Cooled Reactor program at Oak Ridge National Laboratory (ORNL). The focus of this year’s efforts is to continue support of industry needs related to the development of future industry-funded irradiation programs. At ORNL these efforts included the development of a generalized three-dimensional CAD model of an irradiation creep capsules for graphite, cost estimates of the expansion of the Materials Irradiation Facility (MIF), involvement with ASTM D02.F0 “Manufactured Carbon and Graphite Products” and the ASME Boiler and Pressure Vessel Code, and publication of papers supporting these efforts. This report will document the status of these activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using distributions to understand neutron and x-ray production in ICF ignition capsules and other high energy density plasmas

Here this paper describes how x-ray and neutron distribution functions can be useful tools to visualize the conditions measured in many types of plasma physics experiments. In particular, we model a standard inertial confinement fusion ignition capsule that consists of a Si doped plastic ablator surrounding a layer of deuterium–tritium (DT) ice as the yield varies from 18 kJ to 16.7 MJ and use the distribution functions to show that neutrons and high energy x rays (15 keV) are produced under similar conditions when the yield is low. However, as the capsule starts to support a propagating burn due to alpha heating, the x rays and neutrons are produced under somewhat different conditions in different parts of the plasma. In particular, the x-ray production takes place mainly in the hot plastic ablator for the full yield ignition capsule under quite different plasma conditions from the DT region producing the 14 MeV neutrons, which results in x-ray images with larger radii than the corresponding neutron images. These same distribution functions can be applied to many other plasma physics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗