Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stark broadening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Stark-broadened Hydrogen Balmer-line Shapes for DA White Dwarf Synthetic Spectra

Abstract White dwarfs (WDs) are useful across a wide range of astrophysical contexts. The appropriate interpretation of their spectra relies on the accuracy of WD atmosphere models. One essential ingredient of atmosphere models is the theory used for the broadening of spectral lines. To date, the models have relied on Vidal et al., known as the unified theory of line broadening (VCS). There have since been advancements in the theory; however, the calculations used in model atmosphere codes have only received minor updates. Meanwhile, advances in instrumentation and data have uncovered indications of inaccuracies: spectroscopic temperatures are roughly 10% higher and spectroscopic masses are roughly 0.1 M ⊙ higher than their photometric counterparts. The evidence suggests that VCS-based treatments of line profiles may be at least partly responsible. Gomez et al. developed a simulation-based line-profile code Xenomorph using an improved theoretical treatment that can be used to inform questions around the discrepancy. However, the code required revisions to sufficiently decrease noise for use in model spectra and to make it computationally tractable and physically realistic. In particular, we investigate three additional physical effects that are not captured in the VCS calculations: ion dynamics, higher-order multipole expansion, and an expanded basis set. We also implement a simulation-based approach to occupation probability. The present study limits the scope to the first three hydrogen Balmer transitions (H α , H β , and H γ ). We find that screening effects and occupation probability have the largest effects on the line shapes and will likely have important consequences in stellar synthetic spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Competing Line-broadening Mechanisms in Neutron Star Atmospheres: Interference between Motional Stark and Ion Broadening

Neutron star surfaces have extremely high magnetic fields. In the atmosphere, the broadening of spectral lines will be substantial from the dense plasma as well as from the magnetic field. One broadening mechanism of note is due to the motional Stark effect (MSE)—an additional electric field that arises from the motion of the atom in the magnetic field. However, approximate formulae are often used to construct atmosphere models, and the MSE is assumed to be the dominant line-broadening mechanism even in ions. Detailed pressure-broadening models in these extreme magnetic fields are now currently being developed. In these more detailed models, it was suggested that the MSE may not be as large as previously predicted. If correct, this hypothesis implies that neutron star line widths might be dominated by pressure broadening rather than by motional Stark broadening. We find that, in the absence of plasma perturbations, for typical magnetic fields (B = 10 12 G), mid-Z elements, such as oxygen, have motional Stark widths of order 1 eV for transitions between dipole-allowed transitions from the ground state, though higher temperatures and transitions to higher-energy states are expected to have more broadening. The MSE also breaks down selection rules, giving rise to forbidden transitions, which have much larger widths. When plasma perturbations are included, we find that the plasma perturbation and motional Stark processes are not independent and, as a result, the spectral lines become narrow in a nontrivial way and display harmonics of the ion cyclotron frequency.

74 ATOMIC AND MOLECULAR PHYSICS↗

Temperature and density dependence of Kr L-shell spectrum in hot dense plasmas

Kr L-shell spectroscopy modeling results are discussed in this paper, focusing on the n = 4 to n = 2 line transitions of Be- and Li-like Kr ions. Collisional radiative atomic kinetic and Stark-broadened spectral line shape calculations show electron temperature Te and density ne sensitivity in the spectrum. The combination of the Te dependence due to the relative intensity of Be-like to Li-like line emissions in the range from 1.5 to 3 keV and the ne sensitivity from the Stark broadening effect on the line shapes in the range from 5×1023 to 2×1024/ cc results in a spectrum that can be employed to diagnose Te and ne. Two different collisional radiative atomic kinetic models i.e., Prismspect [J. J. MacFarlane, et al., Int. Fusion Sci. Appl. Conf. Proc. 457 (2003)] and ABAKO [Florido, et al., PRE, 80, 056402 (2009)] produce similar results in level populations and spectra. In x-ray spectroscopy of implosion cores, this Kr L-shell spectrum may prove useful in an intermediate Te range in which Ar is too ionized for its K-shell to be of diagnostic value and Kr is not ionized enough for its K-shell emission to be useful.

Physics↗

Plasma decay of nanosecond pulsed laser-produced Ar and Ar–H 2 O sparks at atmospheric pressure

Time-resolved diagnostics were applied to investigate free-electron properties in nanosecond laser-produced discharges generated in atmospheric pressure Ar and in Ar–3%H 2 O. The discharges were generated using 23 ns, 1064 nm laser pulses. Broadband plasma imaging and laser Thomson scattering were combined with optical emission spectroscopy, with particular emphasis on the Stark broadening of the H α and H β lines. The plasma exhibited a bright emission that persists for up to 30–40 µs after breakdown. Plasma emission was then followed by a very weak glow emission that persisted for up to 19 ms after breakdown. Peak electron number density of ∼2 × 10 17 cm −3 and electron temperature of ∼7 eV were measured. An excellent agreement between both techniques was obtained regarding absolute electron number densities. The inferred free-electron temporal decay dynamics are consistent with processes dominated by hydrodynamic expansion and two- and three-body electron–ion recombination. These results provide benchmark data for modeling nanosecond laser discharges and demonstrate the reliability of combining Thomson scattering with Stark broadening in atmospheric laser sparks.

Thomson scattering↗

Characterization of plasma in RF jet interacting with water: Thomson scattering versus spectral line broadening

Here, we carry out a detailed characterization of an Ar radiofrequency plasma jet interacting with liquid. The focus of the paper is measurement of the electron density by examining the Stark broadening of hydrogen Balmer α line and Thomson scattering (TS). Supporting diagnostics are done to investigate the channel evolution and movement, and gas temperature. The comparison of the two approaches shows the caveats and the advantages that should gain attention in future applications. In particular, the plasma channel dynamics have a significant impact on the TS signal and may result in physical phenomena being missed due to channel dislocations. The conclusions of the work elucidate the pitfalls for interpreting the results of TS when the discharge is a dynamic filamentary plasma. This work establishes the temporal evolution of the plasma and the gas parameters in a plasma–liquid system employed for investigation of plasma-induced electrodeless electrochemistry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enigmatic Line Broadening during Solar Flares: Magnetic Field Broadening?

The origin of the extreme broadening observed in chromospheric metal lines during solar and stellar flares—particularly Mg II h and k and Ca II H and K—remains poorly understood. These lines often display Lorentzian-like wings whose widths exceed standard Stark broadening predictions by factors of ∼30, with no known collisional mechanism capable of producing such enhancements. We posit that magnetic fields are responsible for this additional broadening, due to the increase of magnetic activity during flares. A magnetic field distribution of the form P(B) ∝ B −3 reproduces the observed Mg II profile wings while leaving H I Balmer lines and optically thin transitions largely unaffected. To explain the broadening using magnetic fields, the high-B tail can extend up to 10 6 G with extremely low probabilities where the filling factors are ≲10 −6 . We propose that observations of flares using spectropolarimetry can verify whether the anomalous broadening is from magnetic structures in flare ribbons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hollow plasma structure during the breakdown phase of nanosecond pulsed pin–pin discharges generated with overvoltage

Atmospheric pressure nanosecond repetitive pulsed discharges are of interest for applications in combustion, material processing, plasma medicine and gas treatment. Here, the observation of a hollow structure at the ignition stage of such discharge in a pin–pin geometry is reported. Plasma images show that the phenomenon occurs in a variety of gases (helium, humid helium, argon and air) suggesting that it is in first approximation non-species specific. The phenomenon is investigated in detail in pure helium discharges for peak applied voltages between 3 and 6 kV and 200 ns voltage pulse duration by performing time-resolved optical emission spectroscopy measurements of electron density, gas temperature and electric field. All the measurements were performed at the mid-gap during the early stages of the discharge, near the breakdown. The transition from a homogeneous filament to a hollow structure occurs between 4 and 5 kV in helium. Electron density measurements by Stark broadening of the He I line at 492.2 nm show no significant difference in electron densities for the applied voltage between 3 and 6 kV. In all cases, a maximum electron density of about 3.5 × 10 21 m –3 was found. Electric field measurements performed by Stark polarization spectroscopy of the He I transition at 492.2 nm and of its forbidden counterpart show electric field strengths higher than the DC breakdown field of helium at atmospheric pressure consistent with the generation of the discharges with overvoltage. Moreover, a correlation between electric field values and the appearance of the hollow structure is observed and, remarkably, the phenomenon is not sensitive to the pre-ionization level (memory effect). Possible mechanisms for the phenomenon are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid-Density Ion Temperature from Redshifted and Double-Peaked Stark Line Shapes

Heβ spectral line shapes are important for diagnosing temperature and density in many dense plasmas. This work presents Heβ line shapes measured with high spectral resolution from solid-density plasmas with minimized gradients. The line shapes show hallmark features of Stark broadening, including quantifiable redshifts and double-peaked structure with a significant dip between the peaks; these features are compared to models through a Markov chain Monte Carlo framework. Line shape theory using the dipole approximation can fit the width and peak separation of measured line shapes, but it cannot resolve an ambiguity between electron density n e and ion temperature T i , since both parameters influence the strength of quasistatic ion microfields. Here a line shape model employing a full Coulomb interaction for the electron broadening computes self-consistent line widths and redshifts through the monopole term; redshifts have different dependence on plasma parameters and thus resolve the n e – T i ambiguity. The measured line shapes indicate densities that are 80–100% of solid, identifying a regime of highly ionized but well-tamped plasma. This analysis also provides the first strong evidence that dense ions and electrons are not in thermal equilibrium, despite equilibration times much shorter than the duration of x-ray emission; cooler ions may arise from nonclassical thermalization rates or anomalous energy transport. Furthermore, the experimental platform and diagnostic technique constitute a promising new approach for studying ion-electron equilibration in dense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Regimes During Plasma Catalytic Ammonia Synthesis

Herein, we demonstrate that the performance of mesoporous silica SBA-15 and SBA-15-Ag during plasma ammonia synthesis depends on the plasma conditions. At high power, the mesoporous silica SBA-15 without Ag produces the largest amount of ammonia, but the addition of Ag provides a minor benefit at lower powers. Plasma conditions were analyzed through optical emission spectroscopy using N 2 , N 2 + , and NH molecular bands and H α line. Stark broadening of H α line was used to find electron density, and N 2 molecular bands were used to assess N 2 vibrational excitation, important for plasma nitrogen decomposition. At similar input conditions, reactors with SBA-15 have higher electron density and higher N 2 vibrational temperature. Consistent with higher electron density, SBA-15 reactors have stronger N 2 + emission intensity relative to the neutral N 2 . The addition of Ag results in higher N 2 rotational temperature, possibly due to localized heating. From the materials point of view, SBA-15 is a more robust catalyst with good surface area retention after plasma exposure due to the lack of local heating generated when a metal is in the structure. Furthermore, we identify two possible regimes during ammonia synthesis, a metal and a surface-plasma driven. At lower plasma densities, the addition of metal is beneficial, while at higher power and plasma density, the best performance is achieved without the aid of a metal catalyst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unipolar arc plasmas on nanostructured tungsten surfaces under perpendicular magnetic field

Abstract Unipolar arcing is an important phenomenon in terms of wall erosion and the subsequent plasma contamination in nuclear fusion devices. In this study, unipolar arc plasmas are experimentally explored under the presence of the external magnetic field perpendicular to a tungsten (W) sample on which a ‘fuzz’ nanostructure surface is formed. It is found that the fuzz layer thickness, d fuzz , plays a dominant role in determining the motion of arc spots, the arc ignition probability, and arc plasma parameters. High-speed imaging reveals that the motion of arc spots becomes more collective, as d fuzz increases. Interestingly, arc spots make a circle while moving outward. With increasing d fuzz , the amount of eroded W atoms increases, as indicated from an observed increase in the total visible emission intensity, while the arc ignition probability is found to drop. The physical mechanisms are discussed, in detail, based on spectroscopic measurements of the electron temperature, obtained from Boltzmann plots of both W I and W II, and the electron density, determined from Stark broadening of W I lines.

Physics↗

On the origins of the continuum radiation of an underwater nanosecond pulsed discharge: an absolute-intensity optical emission spectroscopy study

The plasma properties of an underwater nanosecond pulsed discharge remain not fully understood despite being extensively studied for several decades. In this work, we focus on the continuum radiation generated in such discharges. The discharge is characterized by power measurements as well as by absolute emission spectroscopy. When observed, Stark broadenings of H α , H β and O (777 nm) are employed for electron number densities measurements. The discharge was generated by a 10 ns main voltage pulse followed by multiple secondary pulses, which last up to 4 μs after the primary pulse. It is shown that a peak power of 3.5 MW and energy of 35 mJ is coupled during the main voltage pulse. A quantitative estimation of the different possible continuum radiation sources is performed through analytical calculations. This includes emission (blackbody, free–bound and free–free bremsstrahlung radiations) and absorption (electron–ion and electron–neutral free–free inverse bremsstrahlung) mechanisms. Our results suggest that electron–neutral free–free bremsstrahlung is the principal mechanism responsible for the strong continuum radiation observed experimentally during the primary pulse. We also show that self-absorption through electron–neutral (and electron–ion) inverse bremsstrahlung plays an important role in the main discharge pulse. Further, our results indicate the non-negligible additional contribution of the H 2 continuum during the first reflected pulse which is likely ignited in bubbles generated by the first discharge pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗