Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stark effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Motional Stark effect imaging first results on the DIII-D tokamak

A motional Stark effect (MSE) imaging diagnostic was benchmarked against existing conventional MSE polarimeters on the DIII-D tokamak and delivered new capabilities for measuring the magnetic pitch angle from 2 neutral beams and on the high field side of DIII-D. Line integration across flux surfaces was considerable for the radial view utilised; yet, the imaging MSE measurements from both beams were self-consistent and in close agreement with conventional MSE measurements. The ferroelectric liquid crystal waveplate used in the imaging polarimeter was discovered to have spatially non-uniform retardance; thus, it is required for the calibration source to replicate the ray paths of the neutral beam emission through the optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymmetries in the motional Stark effect emission on the DIII-D tokamak [Asymmetries in the motional Stark effect emission]

In this study, spectrometer measurements and filter upgrades to a motional Stark effect polarimeter measuring the outer half-radius of the DIII-D tokamak helped to identify asymmetries in the polarization angle of Stark-split emission. The measured polarization angle of the π components differs and is not orthogonal to the σ component. These differences persist over a range of densities and with low levels of background light. Lastly, it is suggested that the difference in the polarization angle between components is from a change in the ellipticity of the emitted light across the Stark components coupled with imperfect polarization preservation from an in-vessel mirror.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

Motional Stark effect (MSE) measurements constrain equilibrium reconstruction of DIII-D tokamak plasmas using the equilibrium code EFIT. In 2007, two new MSE arrays were brought online, bringing the system to three core arrays, two edge arrays, and 64 total channels. We present the first EFIT reconstructions using this expanded system. Safety factor and E{sub R} profiles produced by fitting to data from the two new arrays and one of the other three agree well with independent measurements. Comparison of the data from the three arrays that view the core shows that one of the older arrays is inconsistent with the other two unless the measured calibration factors for this array are adjusted. The required adjustments depend on the toroidal field and plasma current direction, and on still other uncertain factors that change as the plasma evolves. We discuss possible sources of calibration error for this array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-space pseudopotential method for computing the vibrational Stark effect

The vibrational Stark shift is an important effect in determining the electrostatic environment for molecular or condensed matter systems. However, accurate ab initio calculations of the vibrational Stark effect are a technically demanding challenge. In this paper, we make use of density functional theory constructed on a real-space grid to expedite the computation of this effect. Our format is especially advantageous for the investigation of small molecules in finite fields as cluster boundary conditions eliminate spurious supercell interactions and allow for charged systems, while convergence is controlled by a single parameter, the grid spacing. The Stark tuning rate is highly sensitive to the interaction between anharmonicity in a vibrational mode and the applied field. To ensure this subtle interaction is fully captured, we apply three parallel approaches: a direct finite field, a perturbative method, and a molecular dynamics method. Finally, we illustrate this method by applying it to several small molecules containing C–O and C–N bonds and show that a consistent result can be obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum interference between the optical Stark effect and resonant harmonic generation in WS 2

An applied field can modulate optical signals by resonance shifting via the Stark effect. The optical Stark effect uses ultrafast light in the transparency region of a material to shift resonances with speeds limited by the pulse duration or system coherence. In this Rapid Communication, we investigate the optical Stark effect in resonant optical harmonic generation using the A exciton transition of WS 2 . Multidimensional pump-harmonic-probe measurements, in which the probe is second- or third-harmonic emission, reveal not only large Stark shifts that are commensurate with the large optical susceptibilities common to WS 2 excitons, but also behaviors more complex than simple optical Stark effect treatments predict. We show how another manifestation of the Stark effect, brought forth by coherent photon exchange between the pump and harmonic generation fundamental fields, can strongly enhance or suppress harmonic generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a new optical system for Alcator C-Mod motional Stark effect diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Multi-point measurement of |B| in the gas-dynamic trap with a spectral motional Stark effect diagnostic

An upgraded spectral motional Stark effect diagnostic has been installed on the gas-dynamic trap (GDT) experiment to enable spatially resolved measurement of |B|. A new low-noise charge-coupled device detector, combined with enhancements of the diagnostic neutral beam, allows single-shot profile measurements. Previously only single-point motional Stark effect measurements were possible, and detector noise severely limited measurement precision, requiring multi-shot averaging. The plasma pressure profile in GDT is derived from the measured diamagnetic modification of |B| and used to examine the conditions of stable plasma confinement at high plasma pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoherence and dephasing errors caused by the dc Stark effect in rapid ion transport

We investigate the error due to the dc Stark effect for quantum information processing for trapped ion quantum computers using the scalable architecture proposed in D. Wineland et al. [J. Res. Natl. Inst. Stand. Technol. 103, 259 (1998)] and D. Kielpinski et al. [Nature (London) 417, 709 (2002)]. As the operational speed increases, dephasing and decoherence due to the dc Stark effect become prominent as a large electric field is applied for rapidly transporting ions. We estimate the relative significance of the decoherence and dephasing effects and find that the latter is dominant. We find that the minimum possible dephasing is quadratic in the length of a trap and an inverse cubic in the operational time scale. From these relations, we obtain the operational speed range at which the shifts, caused by the dc Stark effect, are no longer negligible, no matter on which trajectory the ion is transported. Without phase correction, the shortest time a qubit can be transferred across a 100-micrometer-long trap, without excessive error, is about 10 ns for a {sup 40}Ca{sup +} ion and 50 ps for a {sup 9}Be{sup +} ion. In practice, the accumulated error is difficult to track and to calculate; thus, our paper gives an estimate for the range of the speed limit imposed by the dc Stark effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical stark effect on CdSe nanoplatelets with mid-infrared excitation for large amplitude ultrafast modulation

The optical Stark effect is a universal response of the electronic structure to incident light. In semiconductors, particularly nanomaterials, the optical Stark effect achieved with sub-band gap photons can drive large, narrowband, and potentially ultrafast changes in the absorption or reflection at the band gap through excitation of virtual excitons. Rapid optical modulation using the optical Stark effect is ultimately constrained, however, by the generation of long-lived excitons through multiphoton absorption. This work compares the modulation achievable using the optical Stark effect on CdSe nanoplatelets with several different pump photon energies, from the visible to mid-infrared. Despite expected lower efficiencies for spectrally-remote pump energies, infrared pump pulses can ultimately drive larger sub-picosecond optical Stark shifts of virtual excitons without creation of real excitons. Importantly, the CdSe nanoplatelets show subpicosecond shifts of the lowest excitonic resonance of up to 22 meV, resulting in change in absorption as large as 0.32 OD (49% increase in transmission), with a long-lived offset from real excitons less than 1% of the peak signal.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Circularly Polarized Optical Stark Effect in CdSe Colloidal Quantum Wells

Colloidal quantum wells, or nanoplatelets, exhibit large, circularly polarized optical Stark effects under sub-band-gap femtosecond illumination. The optical Stark effect is measured for CdSe colloidal quantum wells of several thicknesses and separately as a measure of pump photon energy, pump fluence, and temperature. These measurements show that optical Stark effects in colloidal quantum wells shift the absorption features up to 5 meV, at the intensities up to 2.9 GW.cm -2 and large detuning (>400 meV) of the pump photon energy from the band edge absorption. Optical Stark shifts are underpinned by large transition dipoles of the colloidal quantum wells (mu = 15-23 D), which are larger than those of any reported colloidal quantum dots or epitaxial quantum wells. The rapid (<500 fs), narrow band blue shift of the excitonic features under circular excitation indicates the viability of these materials beyond light emission such as spintronics or all-optical switching.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Motional Stark Effect Diagnostic for NSTX-U

This report describes the development of the motional Stark Effect diagnostic for NSTX. The MSE concept relies upon observation of the Balmer-alpha (n=3 to n=2) emission from a neutral hydrogen beam traversing a plasma. As a beam at high velocity, $\vec{ν}$, passes through the magnetic field in the plasma, $\vec{B}$, it experiences in its reference frame a Lorentz electric field, $\vec{E}$ = $\vec{ν}$ x $\vec{B}$. This electric field causes the spectral emission to be split and polarized as described by the Stark effect. The transition is separated into a set of lines in which the line spacing is linearly proportional to the electric field magnitude, and the line polarization is dependent on the electric field direction. Traditionally, MSE has used polarimetry to determine the polarization angle of the light, and related that to the magnetic field pitch angle in the plasma. The MSE diagnostic was developed under high magnetic field ($>$ 1~T) conditions, and the lower fields of recent high-beta experiments such as NSTX posed challenges to the technique. At low magnetic fields Doppler broadening effects mask the Stark effect. With the use of a narrow bandwidth filter MSE measurements at very low magnetic fields have been obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the Motional Stark Effect Diagnostic Using Laser-Induced Fluorescence (Final Technical Report)

This report describes the development of the motional Stark Effect diagnostic with laser induced fluorescence (MSE-LIF). The MSE concept relies upon observation of the Balmer-alpha (n=3 to n=2) emission from a neutral hydrogen beam traversing a plasma. As a beam at high velocity, $\vec{v}$, passes through the magnetic field in the plasma, $\vec{B}$, it experiences in its reference frame a Lorentz electric field, $\vec{E} = \vec{v} &times; \vec{B}$. This electric field causes the spectral emission to be split and polarized as described by the Stark effect. The transition is separated into a set of lines in which the line spacing is linearly proportional to the electric field magnitude, and the line polarization is dependent on the electric field direction. Traditionally, MSE has used polarimetry to determine the polarization angle of the light, and related that to the magnetic field pitch angle in the plasma. The MSE diagnostic was developed under high magnetic field (> 1 T) conditions, and the lower fields of recent high-beta experiments such as NSTX posed challenges to the technique. At low magnetic fields Doppler broadening effects mask the Stark effect. With the use of a narrow band laser to pump the Balmer-alpha transition many of the broadening effects are eliminated or mitigated so that MSE measurements at very low magnetic fields can be obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ab initio modeling of the motional Stark effect on MAST

A multichord motional Stark effect (MSE) system has recently been built on the MAST tokamak. In MAST the {pi} and {sigma} lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch angle over the observation volume. The measured polarization angle does not relate to one local pitch angle but to an integration over all pitch angles in the observation volume. The velocity distribution of the neutral beam further complicates the measurement. To take into account volume effects and velocity distribution, an ab initio code was written that simulates the MSE spectrum on MAST. The code is modular and can easily be adjusted for other tokamaks. The code returns the intensity, polarized fraction, and polarization angle as a function of wavelength. Results of the code are presented, showing the effect on depolarization and wavelength dependence of the polarization angle. The code is used to optimize the design and calibration of the MSE diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrumentation for a multichord motional Stark effect diagnostic in KSTAR

The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1–3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The motional Stark effect polarimeter in the HL-2A tokamak

A 7-channel motional Stark effect polarimeter based on four polarizers and a spectrometer has been developed in the HL-2A tokamak, which is the first time successful utilizing this kind of polarimeter on a tokamak. The accuracy of the angle can reach ±0.25° in the calibration experiments. Pilot experiments of measuring the magnetic pitch angle have been successfully carried out in the weak motional Stark effect plasma discharge with toroidal magnetic field of ∼1.3 T and beam energy of ∼25 keV/amu. The pitch angles of magnetic field are obtained for 7 spatial points covering 24 cm along major radius with time resolution of 40 ms; the profiles of safety factor are obtained by combining with the Equilibrium and Reconstruction Fitting Code. The core value of safety factor (q) is less than 1 during the sawtooth oscillation and the position of q = 1 surface is well consistent with the results measured by soft X-ray array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗