Search NASA⌕ Search

SEARCH · Search NASA

Results for “Static air temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CHELAX-BNF: Fast Response Temperature by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 to June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in the form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

Fast Response Temperature by airborne measurements over BNF

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 9 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

NOx mediated formation of ε – UO 3 during thermal decomposition of uranyl nitrate hexahydrate under static air conditions

The thermal decomposition of uranyl nitrate hexahydrate in air at temperatures of 650 – 800 °C is expected to yield α – U 3 O 8 through intermediate UO 3 phases. Here, n this study, Raman spectroscopy complimented by powder X-ray diffraction revealed the unexpected formation of ε – UO 3 as an accompanying phase during thermal decomposition of UNH at 700 °C under static air conditions. Experiments demonstrated that ε – UO 3 does not form during the initial ramp up stage nor during the high temperature heating period; but instead forms during the cooling stage between 250 – 400 °C. Additional experiments revealed that UNH initially decomposes through an amorphous UO 3 intermediate prior to α – U 3 O 8 formation. Attempts to bypass the U 3 O 8 precursor in the formation of ε – UO 3 were unsuccessful, supporting the necessity of U 3 O 8 (α – U 3 O 8 in this study) in the formation of ε – UO 3 . The observed phase evolution is proposed to result from the NOx species generated during UNH thermal decomposition, which create localized oxidizing conditions within the furnace under static air conditions. Furthermore, a predominantly phase pure ε – UO 3 was synthesized under static air conditions through the addition of an extra plateau at 250 °C during the cooling step. These findings demonstrate the importance of gas-phase chemistry and cooling conditions in uranium oxide phase evolution and provide additional insight into ε – UO 3 formation pathways.

Epsilon uranium trioxide↗

Effect of Cr and Ni concentrations on resilience of cast Nb- alloyed heat resistant austenitic steels at extreme high temperatures

Austenitic Cr–Ni alloyed heat resistant steels with Nb additions are used for intensively thermo-mechanically loaded cast components working in extreme high temperature oxidizing environment. Their performance during static oxidation and transient thermo-mechanical loading was investigated to recommend an optimal cost-effective Cr/Ni composition of Nb-alloyed austenitic class steels. Here, the static oxidation and transient thermo-mechanical behavior of three austenitic steels with different Cr/Ni alloying levels were investigated and compared for variety of working conditions. Static oxidation was performed between 900 °C and 1000 °C in air for 400 h. The critical temperature which increases spallation during static oxidation was determined for each of the steel alloying levels. In addition, thermal cycling of a constrained specimen was done with varying upper cycling temperatures between 850 °C and 1000 °C. SEM and TEM analyses were supported by thermodynamic simulation of the phases precipitated in the metal matrix and the structure of formed oxide layers. These studies were used to determine the mechanisms of degradation of thermo-mechanically loaded Cr/Ni austenitic steels at extreme high temperatures. A recommendation for a cost-effective Cr/Ni alloying level for different working conditions was determined.

36 MATERIALS SCIENCE↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Xanthos-Lake Dataset

The Xanthos-Lake v1.0 dataset provides the input data, trained machine-learning models, and simulation outputs needed to characterize lake water balance, snow and ice conditions, and mixing-layer temperature within the Xanthos global hydrological modeling framework. The dataset supports lake representation across a wide range of lake sizes and hydroclimatic conditions by combining xLSIM, a basin-specific machine-learning emulator of lake snow, ice, ice-cover fraction, and mixing-layer temperature, with the Xanthos-Lake water-balance model. The archive contains NetCDF datasets used to train and evaluate xLSIM, trained model weights, processed meteorological and lake-property inputs, and basin- and lake-category-specific simulation outputs. These materials are organized into four primary data groups, described below. Snowice_model_inputs: Contains the NetCDF input data used to train xLSIM. The xLSIM machine-learning framework uses three lake-based datasets. The meteorological forcing dataset provides monthly relative humidity, specific humidity, surface wind speed, maximum and minimum air temperature, downward longwave and shortwave radiation, snowfall, surface air pressure, and total precipitation. Lake surface area is included as an additional static predictor. The target-state dataset provides lake ice thickness, snow depth, snow cover, and lake mixing-layer temperature, while a companion lake-surface dataset provides the lake ice-cover fraction. Before training, ice thickness and snow depth are converted from meters to centimeters, mixing-layer temperature is converted from kelvin to degrees Celsius and constrained to nonnegative values, and ice-cover fraction is converted from a fraction to a percentage. The predictor variables are normalized using statistics calculated across the selected lakes and time steps. Snowice_model_outputs: Contains the NetCDF outputs generated by xLSIM. For each basin, xLSIM produces a file containing observed and predicted lake-state variables for the training, validation, and testing periods. The modeled variables include lake ice thickness, snow depth, snow cover, mixing-layer temperature, and lake ice-cover fraction. For basins without a sufficiently persistent snow-and-ice signal, the emulator predicts only mixing-layer temperature. The outputs also include training and validation loss histories, the selected model configuration, identifiers of the lakes used in training, and SHAP-based feature-importance information at the global, lake, and seasonal-regime levels. The trained machine-learning model weights are provided separately within the dataset archive. Together, these files support model evaluation and subsequent coupling with the Xanthos-Lake water-balance framework. XanthosLAKES: Contains the NetCDF input data used by the Xanthos-Lake framework. Monthly meteorological inputs include relative and specific humidity, downward shortwave and longwave radiation, mean, maximum, and minimum air temperature, wind speed, precipitation, snowfall, and surface air pressure. Static lake-property datasets provide lake identifiers, geographic locations, surface area, volume, mean depth, elevation, drainage area, fetch, outlet-routing information, and associated Xanthos grid-cell attributes. Separate bathymetric datasets provide the coefficients of the area–depth and volume–depth relationships for each aggregated lake unit. GLEV-based records provide observed lake surface area and evaporation data used to initialize lake states, define reference conditions, and calibrate and evaluate the model. Xanthos-Lake Outputs: Contains the basin- and lake-category-specific NetCDF outputs generated by Xanthos-Lake. Monthly variables include lake surface area, storage volume, outlet discharge, evaporation rate, evaporation volume, lake–groundwater exchange, lake inflow, ice thickness, snow depth, snow-cover fraction, ice-cover fraction, and mixing-layer temperature. The files also contain lake-specific calibration and validation statistics, including normalized root-mean-square error, mean absolute error, Nash–Sutcliffe efficiency, Kling–Gupta efficiency, and percent bias. Stored calibrated and derived parameters include the weir discharge coefficient, fractional freeboard, groundwater exchange coefficient, reference water level, corresponding reference surface area and storage volume, weir-width adjustment factor, and the fraction of routed inflow entering the lake. Basin identifiers, lake category, simulation period, calibration and validation periods, and parameter-schema information are retained as NetCDF metadata.

Abeshu, Guta [Pacific Northwest National Laborator↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Impact of titanium content on the thermo-mechanical and oxidation response of TiAlTa

This study aimed to analyze how the addition of titanium (Ti) to TiAlTa alloys affects their mechanical properties (Young’s modulus and hardness) and oxidation behavior. Alloys with three different Ti additions and equi-atomic Al and Ta were fabricated with nominal compositions of 33Ti-33Al-33Ta at%, 50Ti-25Al-25Ta at%, and 70Ti-15Al-15Ta at%. Phase identification of as-processed and compositionally homogenized alloys was conducted by coupling various electron microscopy, diffraction, and chemical analysis techniques. Composition and structures were modeled using CALPHAD-based phase predictions and compared with experimental results. Each of the alloys exhibited a unique set of microstructures with distinctly different ordered precipitates, dependent on cooling rate and chemical composition. Subsequently, nanoindentation tests were performed at temperatures of 25°C, 250°C, 500°C, and 750°C. Oxidation studies were conducted under static air at 750°C for up to 200 h. 33Ti-33Al-33Ta at% and 70Ti-15Al-15Ta at% alloys showed higher hardness and modulus than 50Ti-25Al-25Ta at% at room temperature. The 50Ti-25Al-25Ta at% alloy exhibited higher hardness and modulus values but lower oxidation resistance at 750°C when compared with the other specimens. The X-ray photoelectron spectroscopy experiments were conducted to further analyze the oxides present in the samples. Despite each sample displaying combinations of mixed oxide layers, TiO 2 was the preferred oxide forming in the 50Ti-25Al-25Ta composition, while the other samples preferred to form Al 2 O 3 . In conclusion, the findings from this systematic exploration of phase evolution in the TiAlTa alloy space provide insights for optimized material chemistries, processing, and properties.

36 MATERIALS SCIENCE↗

Tungsten single-atom catalysts for the efficient conversion of isobutene into highly branched liquid hydrocarbons

The catalytic transformation of isobutene into branched liquid hydrocarbons is crucial for the production of reformulated gasoline and fuel additives. Conventional supported catalysts often lack high activity and selectivity toward the desired highly branched dimers and trimers in isobutene oligomerization. Here, by developing a tungsten single-atom catalyst (W SAC ) atomically dispersed on a silica-doped alumina (SDA) support, we report that the W SAC /SDA catalyst enables efficient and selective conversion of isobutene into highly branched C 8 and C 12 liquid olefins while suppressing the formation of heavier hydrocarbons. The atomically dispersed W 1 –O 3 moieties incorporated within the SDA support were synthesized via a high-temperature pyrolysis of a templating zinc metal–organic framework (Zn-MOF) under argon, followed by annealing in static air. The W SAC /SDA catalysts with 1.6–3.7 wt% W loading exhibited single-atom dispersion (∼0.2 nm) and outstanding performance, achieving up to 60% and 95% selectivity to branched C8 olefins at 150 °C and 250 °C, respectively, under ambient pressure. With the demonstrated high activity, selectivity, and stability, the W SAC /SDA catalyst system presents a promising platform for next-generation heterogeneous catalysts for the efficient and selective upgrading of isobutene into high-performance fuel additives.

Branched Olefins↗

Root Dynamics Mitigate Warm and Dry Biases over the Central United States

The central United States frequently exhibits warm and dry biases in simulations of summertime conditions, a persistent feature that remains unresolved. While previous studies linked these biases to misrepresented surface energy exchanges, the role of belowground processes remains poorly understood. Here, we demonstrate that inadequate representation of root water uptake in land surface models contributes to this bias. Using both offline Noah-MP and coupled WRF-Noah-MP simulations with static and dynamic root water uptake schemes, we show that the inclusion of dynamic root processes reduces 2-m air temperature biases and enhances precipitation, primarily by increasing the rain rate of convective systems. Offline and coupled simulations further reveal that the cooling effects and precipitation increases are amplified through positive land-atmosphere feedback, active only in the coupled model. These findings highlight an important role of root in modulating land-atmosphere interactions and underscore the need to refine root-zone processes to improve regional atmospheric simulations.

Yang, Zhao (ORCID:0000000288027130)↗

Time-domain self-broadened and air-broadened nitrogen S-branch Raman linewidths at 80–200 K recorded in an underexpanded jet

We report pure-rotational N 2 –N 2 , N 2 –air, and O 2 –air S-branch linewidths for temperatures of 80–200 K by measuring the time-dependent decay of rotational Raman coherences in an isentropic free-jet expansion from a sonic nozzle. We recorded pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) spectra along the axial centerline of the underexpanded jet, within the barrel shock region upstream of the Mach disk. The dephasing of the pure-rotational Raman coherence was monitored using probe-time-delay scans at different axial positions in the jet, corresponding to varying local temperatures and pressures. The local temperature was obtained by fitting CARS spectra acquired at zero probe time delay, where the impact of collisions was minimal. The measured decay of each available Raman transition was fit to a dephasing constant and corrected for the local pressure, which was obtained from the CARS-measured static temperature and thermodynamic relationships for isentropic expansion from the known stagnation state. Nitrogen self-broadened transitions decayed more rapidly than those broadened in air for all temperatures, corresponding to higher Raman linewidths. In general, the measured S-branch linewidths deviated significantly in absolute and relative magnitudes from those predicted by extrapolating the modified exponential gap model to low temperatures. The temperature dependence of the Raman linewidth for each measured rotational state of nitrogen (J ≤ 10) and oxygen (N ≤ 11) was fit to a temperature-dependent power law over the measurable temperature domain (80–200 K) and extrapolated to both higher rotational states and room temperature. Furthermore, the measured and modeled low-temperature linewidth data provided here will aid low temperature gas-phase pressure measurements with fs/ps CARS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗