Search NASA⌕ Search

SEARCH · Search NASA

Results for “Static magnetic field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Generation of a quasi-static magnetic field by a circularly polarised laser pulse due to tunnelling gas ionisation

We present a theoretical model of the quasi-static magnetic field generation in a laser channel, which is formed behind the front of a short laser pulse that ionises a gas. The generation of a magnetic field is caused by the appearance of the electron pressure anisotropy during tunnelling ionisation of atoms. In the considered case of subrelativistic laser light intensities, the generated magnetic field can reach ∼1 MG with an energy transformation ratio of about 1 %, which paves the way for identifying the proposed mechanism when use is made of a wide class of ultrashort pulse lasers. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils

Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. Here, we demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time time-dependent density functional theory in Quantum Espresso and related codes

A set of subroutines that interact with an existing computer program, Quantum Espresso (QE), that takes a set of electronic orbitals from QE and propagates them forward in time in response to a number of perturbations. These perturbations include the motion of ions and a wide spectrum of applied electromagnetic fields (e.g., static magnetic fields, slowly-varying electric fields, x-rays, etc.). From the time evolution of the electronic orbitals comes time-varying values of physical observables like the electronic charge and current densities and atomic forces. These are further post-processed to yield properties of interest like stopping powers, conductivities, and the dynamic structure factor. The electronic orbitals are described in a plane wave basis and the equations of motion are carried out using a unitary or approximately unitary time propagation algorithm. Related work will include subroutines for interfacing this capability, as well as others that already exist within QE, with a fork of QE that is more extensible and modular.SAND2019-12611 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Baczewski, Andrew↗

Phase-controlled direct laser acceleration enabled by longitudinal variation of the laser-driven quasi-static plasma magnetic field

Direct laser acceleration (DLA) enables energy transfer from an ultra-high-intensity laser to plasma electrons and underpins many laser-driven particle and radiation-source concepts. A laser-driven azimuthal plasma magnetic field is a key player in this process: it confines energetic electrons, induces betatron oscillations, and makes possible a resonant interaction between the betatron motion and the laser field. While this betatron resonance can enhance electron energy gain, the gain itself generally drives frequency detuning and promotes largely reversible energy exchange that limits net acceleration. Here we show, using a test-electron model with prescribed fields, that a slow longitudinal increase of the quasi-static plasma magnetic field qualitatively changes DLA by introducing hysteresis in the ratio of the betatron frequency to the laser frequency experienced by the electron, so that this ratio depends on the prior evolution of the electron even at the same energy. This hysteresis enables phase control of the electron-laser energy exchange and suppresses the usual reversibility of DLA, allowing electrons to retain the acquired energy and sustain energy gain without intermittent losses.

direct laser acceleration↗

Heating system with induction power supply and electromagnetic acoustic transducer with induction power supply

A system for heating a fluid and an electromagnetic acoustic transducer EMAT system is provided. Both systems have a drive circuit. The amount of heat and the amplitude (and acceleration) of the vibrations is respectively controllable by controlling an input to a terminal of a switch. The heating system comprises a porous graphite foam conductor which is exposed to an electromagnetic field generated by an oscillating circuit. When exposed, the foam conductor conducts induced electric current which heats the same and a fluid in contact with the conductor. The EMAT system comprises at least one magnet configured to generate a static magnetic field, an oscillating circuit and a working element. The working element, when exposed to the static magnetic field and the electromagnetic field produced by the oscillating circuit, vibrates against a load. The vibrations dry the load.

Kisner, Roger A.↗

Exact-Two-Component Complete Active Space Method with Variational Treatment of Magnetic Field and Spin–Orbit Coupling: Application to X-ray Magnetic Circular Dichroism Spectroscopy

We introduce an exact-two-component complete active space self-consistent-field (X2C-CASSCF) method formulated under the restricted-magnetic-balance condition. This framework allows for the nonperturbative treatment of static magnetic fields using gauge-including atomic orbitals (GIAOs). The GIAO-X2C-CASSCF methodology effectively captures all microstates within the same 2J + 1-degenerate manifold and their splitting in a static magnetic field, which are not accessible through single-reference-based methods. We also present mathematical recursive expressions for evaluating one-electron relativistic integrals by using GIAOs in the presence of a finite magnetic field. Benchmark studies include oxygen and nitrogen K-edge X-ray magnetic circular dichroism spectroscopy (XMCD) for closed-shell organic compounds, as well as L-edge XMCD spectroscopy for the high-spin open-shell transition metal ion Mn 2+ and the tetrahedral Mn(II)O 4 6– complex.

Chemical calculations↗

Quantitative measurements of reactive oxygen species partitioning in electron transfer flavoenzyme magnetic field sensing

Biological magnetic field sensing that gives rise to physiological responses is of considerable importance in quantum biology. The radical pair mechanism (RPM) is a fundamental quantum process that can explain some of the observed biological magnetic effects. In magnetically sensitive radical pair (RP) reactions, coherent spin dynamics between singlet and triplet pairs are modulated by weak magnetic fields. The resulting singlet and triplet reaction products lead to distinct biological signaling channels and cellular outcomes. A prevalent RP in biology is between flavin semiquinone and superoxide (O 2 •–) in the biological activation of molecular oxygen. This RP can result in a partitioning of reactive oxygen species (ROS) products to form either O 2 •– or hydrogen peroxide (H 2 O 2 ). Here, we examine magnetic sensing of recombinant human electron transfer flavoenzyme (ETF) reoxidation by selectively measuring O 2 •– and H 2 O 2 product distributions. ROS partitioning was observed between two static magnetic fields at 20 nT and 50 μT, with a 13% decrease in H 2 O 2 singlet products and a 10% increase in O 2 •– triplet products relative to 50 µT. RPM product yields were calculated for a realistic flavin/superoxide RP across the range of static magnetic fields, in agreement with experimental results. For a triplet born RP, the RPM also predicts about three times more O 2 •– than H 2 O 2 , with experimental results exhibiting about four time more O 2 •– produced by ETF. The method presented here illustrates the potential of a novel magnetic flavoprotein biological sensor that is directly linked to mitochondria bioenergetics and can be used as a target to study cell physiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Momentum space AC Josephson effect and intervalley coherence in multilayer graphene

Electron transport driven by the phase coherence and interference of quantum many-body wavefunctions is a fascinating phenomenon with potential technological significance. Superconductivity, for example, enables dissipationless transport through macroscopic phase twisting, while charge-density waves show broadband noise and AC-DC interference once their phase is depinned. We identify an analogous phase-coherent dynamics in the intervalley-coherent (IVC) state frequently observed in rhombohedral multilayer graphene. We show that a static magnetic field drives an oscillating intervalley current, which produces an oscillating orbital magnetization and thereby a detectable AC Hall response. This mechanism is similar to the Josephson effect observed in superconductors but now happening in momentum space. In this analogy, the static magnetic field acts as the DC voltage, while the oscillating intervalley current is the AC Josephson current. We provide microscopic calculations of all the phase-number free-energy parameters in rhombohedral trilayer graphene, establishing this effect as an experimental signature of IVC order.

electronic properties and materials↗

Nonexistence of integrable nonlinear magnetic fields with invariants quadratic in momenta

Nonlinear, completely integrable Hamiltonian systems that serve as blueprints for novel particle accelerators at the intensity frontier are promising avenues for research, as Fermilab’s Integrable Optics Test Accelerator (IOTA) example clearly illustrates. Here, we show that only very limited generalizations are possible when no approximations in the underlying Hamiltonian or Maxwell equations are allowed, as was the case for IOTA. Specifically, no such systems exist with invariants quadratic in the momenta, precluding straightforward generalization of the Courant-Snyder theory of linear integrable systems in beam physics. We also conjecture that no such systems exist with invariants of higher degree in the momenta. This leaves solenoidal magnetic fields, including their nonlinear fringe fields, as the only completely integrable static magnetic fields, albeit with invariants that are linear in the momenta. The difficulties come from enforcing Maxwell equations; without constraints, we show that there are many solutions. In particular, we discover a previously unknown large family of integrable Hamiltonians.

97 MATHEMATICS AND COMPUTING↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Parallel pumping of magnons in inhomogeneous spin textures probed through NV spin relaxometry

We combine micromagnetic simulations and nitrogen-vacancy (NV) defect center spin relaxometry measurements to study magnon modes in inhomogeneous spin textures. A thin, micrometer-scale ferromagnetic disk is magnetized in a vortex state in which the magnetization curls around a central core. Micromagnetic simulations show that at zero applied field, the magnetization dynamics of the disk consist of a low frequency gyrotropic mode and higher frequency azimuthal magnon modes, all far detuned from the NV spin transition frequencies. An in-plane static magnetic field breaks the azimuthal symmetry of the vortex state, resulting in the magnon modes transforming in frequency and spatial profile as the field increases. Experimentally, we probe the dynamics of vortex magnetization as a function of applied in-plane static field and ac driving frequency by optically monitoring a nearby NV defect center spin. At certain values of the applied magnetic field, we observe enhanced spin relaxation when driving at twice the frequency of the NV ground state spin transition in optically detected magnetic resonance measurements. We attribute this effect to parallel pumping of a magnon mode in the disk producing magnons at half the excitation frequency. Micromagnetic simulations support this finding, showing spatial and spectral overlap of a confined magnon mode and an NV spin transition, with sufficient interaction strength to explain the observed signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals; static magnetic fields must also be tightly controlled to manage measurement resolution. Several tools are being applied to the problem, including mu-metal shielding, field biasing, and a suite of magnetometers. This report details the development of a magnetic field monitoring system to be built from commercially available parts and installed at seventeen locations, one for each of the modular sections making up the length of the MAGIS-100 apparatus.

Arce, Edwin [Unlisted, US, CA]↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

Laser Plasma Interaction in the MG Magnetic Field (Final Report)

Strong magnetic fields change properties of plasma. Employment of the magnetic fields can improve conditions for inertial confinement fusion. Compression and heating of the magnetized plasma is a base of the MagLIF pulsed power approach to the controlled fusion. Study of expansion and heating of plasma in the external magnetic fields, development of plasma instabilities, parametric and other effects are important for basic physics and applications. The main goal of the research for the grant was experimental investigation of laser produced plasma in the well characterized and controlled MG magnetic fields. We developed a platform for investigation of high intensity laser-plasma interaction (LPI) in the MG fields using a university-scale pulsed power machine. A Zebra machine at UNR generated transverse magnetic fields of 3 MG on the surface of the rod load and longitudinal fields of 1.4 MG in the coil loads. The magnetic fields were characterized with two-color Faraday rotation diagnostics. The pulsed power machine provided almost static magnetic fields for LPI compared to the much faster laser driven magnetic fields. We found that eddy currents in the rising magnetic field generate plasma on the metal targets. Eddy currents did not impact Si and CH dielectric targets. A Leopard laser with intensity in the focus up to 10 19 W/cm 2 produced plasma in the MG magnetic fields. The modified reflected Faraday diagnostics was used to study laser driven B-field at the MTW laser at Laboratory for Laser Energetics, UR. We demonstrated a slow dependence of the magnetic field in the coil on the applied laser intensity. The magnetic field increased by a factor of 2 if laser intensity increased by a factor of 30. This scaling is important for comparison of experiments at different laser facilities. Expansion of the plasma in the 2-3 MG external B-field was studied. Laser-produced plasma in the azimuthal magnetic field took the unique form of a thin disc expanding radially with a velocity of 250 km/s and confined in the vertical direction. A HYDRA MHD program at the University of Rochester was applied for simulations of LPI in the magnetic field B >3 MG. Simulations for the plasma disc parameters and the expansion dynamics were in a good agreement with experiments. Generation of narrow dense plasma jets in the longitudinal magnetic field of 0.6-0.8 MG was studied. Narrow plasma jets reached a length of 3-4 mm with the electron plasma density of (0.2-1.2)x10 20 cm -3 . A jet tip propagated with the velocity of 160-200 km/s. MHD simulations showed a good agreement of the dynamics of the formation of plasma jets with experiments. These jets are relevant to astrophysical jets. Simulations of K-shell spectra of Si plasma was performed for LPI in the B-field. The laser prepulse generated plasma near the laser target. A PrismSPECT model with a MeV electron beam produced by the laser was used. The spectral modelling showed the increased plasma density by a factor by 2-3 in the magnetic field. This was in agreement with the observed dynamics of the plasma plume confined by the axial magnetic field. The two-plasmon decay was studied in the 2.5-3 MG transversal magnetic fields. Strong 2-3.5 nm spectral widening and a 2-4 nm shifts of “red” and “blue” 3/2ω 0 spectral components were observed. The large shift and widening exceed the expected temperature and magnetic shift. PIC simulations are performing to clarify physics of this effect. The experimental research program for the grant is completed. New plasma effects in the MG fields were studied at the university-scale pulsed power generator. Two graduate and two undergraduate UNR and UR students carried experiments at the Zebra generator, supported and developed plasma diagnostics, provided data processing, and performed MHD simulations of LPI in the strong magnetic field. Research results are published in 9 referred papers and presented in 12 conferences. Program manager: Kramer U. Akli; Collaborators: R. C. Mancini and H. Sawada, University of Nevada, Reno (UNR); R. Betti and A. V. Maximov, University of Rochester (UR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

Net energy gain in direct laser acceleration due to enhanced dephasing induced by an applied magnetic field

Even in the situation where an electron interacts with a single plane wave, the well-known dynamical adiabaticity can be broken when an applied magnetic field is present, which will act to increase the dephasing rate of the electron during the interaction. Here we demonstrate this for the case where there is a uniform static magnetic field which is oriented either parallel or perpendicular to the electric field of the incident plane wave, and perpendicular to the direction of its propagation. The described energy gain phenomenon has direct relevance to laser-plasma interactions that involve external magnetic fields generated by laser-driven capacitor coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗