Search NASA⌕ Search

SEARCH · Search NASA

Results for “Static pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-ray free electron laser heating of water and gold at high static pressure

Probing of reactive materials such as H 2 O ices and fluids at the high pressures and temperatures of planetary interiors is limited by unwanted chemical reactions and confinement failure. Faster experiments can mitigate such issues, but the common approach of adiabatic compression limits the conditions achieved. This study demonstrates a fast experimental strategy for the creation and probing of selected extreme states using static compression coupled with ultrafast X-ray laser heating. Indirect X-ray heating of H 2 O through the use of a gold absorber is evidenced by sample melting inferred from textural changes in the H 2 O diffraction lines and inter-dispersion of gold and H 2 O melts. Coupled with numerical analysis of femtosecond energy absorption, thermal equilibration, and heat transfer, all evidence indicates that temperatures in excess of an electron volt have been reached in the H 2 O at high pressure. Even after repeated heating, samples stayed chemically unchanged from the starting material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Exponents of Turbulent Static Pressure Structure Function in the Inertial Subrange

The measured variations in the turbulent static pressure structure function D pp (r) with scale $r$ in the roughness sublayer above a subarctic forest are empirically shown to exhibit exponents that are smaller than $r$ 4/3 predicted for the inertial subrange (ISR). Three hypotheses are offered to explain these deviations. The first is based on conventional intermittency correction to the averaged turbulent kinetic energy dissipation rate, the second is based on shearing introducing deviations from locally isotropic state that must be sensed by both velocity and pressure structure functions, and the third is based on large and inertial scale pressure interactions that persist at values of $r$ within the resolvable ISR. The third hypothesis is shown to yield superior results, which allows a new formulation for D pp (r) to be derived that accommodates such finite interactions.

structure function↗

Methodology for Determining Impulse and Quasi-Static Pressure Loading for Design of 6-ft Inner Diameter Confinement Vessel

A brief study of the TNT-equivalence of PBX-9501 is presented herein utilizing a new basis via application of one-dimensional spherical (1DS) hydrocode models in a 6-ft ID confinement vessel geometry with no internal furniture. Specifically, TNT-equivalence herein is based upon two separate features: (1) matching the peak reflected specific impulse of PBX-9501 to TNT under detonation process, and (2) matching quasi-static peak gas pressure of PBX-9501 to TNT at steady-state.

42 ENGINEERING↗

Materials synthesis at terapascal static pressures

Theoretical modelling predicts very unusual structures and properties of materials at extreme pressure and temperature conditions. Hitherto, their synthesis and investigation above 200 gigapascals have been hindered both by the technical complexity of ultrahigh-pressure experiments and by the absence of relevant in situ methods of materials analysis. Here we report on a methodology developed to enable experiments at static compression in the terapascal regime with laser heating. We apply this method to realize pressures of about 600 and 900 gigapascals in a laser-heated double-stage diamond anvil cell, producing a rhenium–nitrogen alloy and achieving the synthesis of rhenium nitride Re 7 N 3 —which, as our theoretical analysis shows, is only stable under extreme compression. Full chemical and structural characterization of the materials, realized using synchrotron single-crystal X-ray diffraction on microcrystals in situ, demonstrates the capabilities of the methodology to extend high-pressure crystallography to the terapascal regime.

36 MATERIALS SCIENCE↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Model, data, and code for paper "Modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x"

The data package includes data, model, and code that support the analyses and conclusions in the paper titled “modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x”. The primary goal of this paper is to demonstrate that key streamflow properties such as water depth, flow velocity, and dynamic pressure in a natural river at 30-kilometer scale over 5 years can be reliably and efficiently modeled using the computational framework presented in this paper. To support the paper, various data types from remote sensing, field observations, and computational models are used. Specific details are described as follows. Firstly, the river bathymetry data was obtained from a Light Detection and Ranging (LiDAR) survey. This data is then converted to a triangulated surface format, STL, for mesh generation in OpenFOAM. The STL data can be found in Model_Setups/BaseCase_2013To2015/constant/triSurface. The OpenFOAM mesh generated using this STL file can be found in constant/polyMesh. Other model setups, boundary and initial conditions can be found in /system and /0.org under folder BaseCase_2013To2015. A similar data structure can also be found in BaseCase_2018To2019 for the simulations during 2018 and 2019. Secondly, the OpenFOAM simulations need the upstream discharge and water depth information at the upstream boundary to drive the model. These data are generated from a one-dimensional hydraulic model and the data can be found under the folder Model_Setups /1D model Mass1 data. The mass1_65.csv and mass1_191.csv files include the results of the 1D model at the model inlet and outlet, respectively. The Matlab source code Mass1ToOFBC20182019.m is used to convert these data into OpenFOAM boundary condition setups.With the above OpenFOAM model, it can generate data for water surface elevation, flow velocity, and dynamic pressure. In this paper, the water surface elevation was measured at 7 locations during different periods between 2011 and 2019. The exact survey locations (see Fig1_SurveyLocations.txt) can be found in folder Fig_1. The variation of water stage over time at the 7 locations can be found in folder /Observation_WSE. The data type include .txt, .csv, .xlsx, and .mat. The .mat data can be loaded by Matlab.We also measured the flow velocities at 12 cross-sections along the river. At each cross-section, we recorded the x, y locations, depth, three velocity components u,v,w. These data are saved to a Matlab format which can be found under folder /Observation_Velocity and /Fig_1. The relative locations of velocity survey locations to the river bathymetry can be found in Figure 1c.The water stage data at the 7 locations from OpenFOAM, 1D, and 2D hydraulic models are also provided to evaluate the long-term performance of 3D models vs 1D/2D models. The water stage data for the 7 locations from OpenFOAM have been saved to .mat format and can be found in /OpenFOAM_WSE. The water stage data from the 1D model are saved in .csv format and can be found in /Mass1_WSE. The water stage from the 2D model is saved as .mat format and can be found in / Mass2_WSEIn addition, the OpenFOAM model outputs the information of hydrostatic and hydrodynamic pressure. They are saved as .mat format under folder /Fig_11/2013_1. As the files are too large, we only uploaded the data for January 2013. The area of different ratio of dynamic pressure to static pressure for all simulation range, i.e., 2013-2015, are saved to .mat format. They can be found in /Fig_11/PA. Further, the data of wall clock time versus the solution time of the OpenFOAM modeling are also saved to .mat format under folder /Fig_13/LogsMat. In summary, the data package contains seven data types, including .txt, .csv, .xlsx, .dat, .stl, .m, and .mat. The former 4 types can be directly open using a text editor or Microsoft Office. The .mat format needs to be read by Matlab. The Matlab source code .m files need to be run with Matlab. The OpenFOAM setups can be visualized in ParaView. The .stl file can be opened in ParaView or Blender. The data in subfolders Fig_1 to Fig_10 and Fig_12 are copied from the aforementioned data folders to generate specific figures for the paper. A readME.txt file is included in each subfolder to further describe how the data in each folder are generated and used to support the paper.Please use the data package's DOI to cite the data package. Please contact yunxiang.chen@pnnl.gov if you need more data related to the paper.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

The Turbulent Pressure Spectrum Within the Roughness Sublayer of a Subarctic Forest Canopy

The turbulent static pressure spectrum E pp (k x ) as a function of longitudinal wavenumber k x in the roughness sublayer of forested canopies is of interest to a plethora of problems such as pressure transport in the turbulent kinetic energy budget, pressure pumping from snow or forest floor, and coupling between flow within and above canopies. Long term static pressure measurements above a sub-arctic forested canopy for near-neutral conditions during the winter and spring were collected and analyzed for three snow cover conditions: trees and ground covered with snow, trees are snow free but the ground is covered with snow, and snow free cover. In all three cases, it is shown that E pp (k x ) obeys the attached eddy hypothesis at low wavenumbers (1/δ < k x < 1/z) —with E pp (k x ) ∝ u$^4_*$k$^{-1}_x$ and Kolmogorov scaling in the inertial subrange at higher wavenumbers—with E pp (k x ) ∝ ϵ 4/3 k x -7/3 , where u * is the friction velocity at the canopy top, is the mean turbulent kinetic energy dissipation rate, z is the distance from the snow top, and is the boundary layer depth. The implications of these two scaling laws to the normalized root-mean squared pressure C p = o p /u$^2_*$ and its newly proposed logarithmic scaling with normalized wall-normal distance z/δ are discussed for snow covered and snow free vegetation conditions. The work here also shows that k$^{-1}_x$ the in the E pp (k x ) appears more extensive and robust than its longitudinal velocity counterpart.

Aslan, Toprak [Finnish Meteorological Inst., Helsi↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 4 - Raw Data

Sequence 4: Static Pressure Calibration (P) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 30° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. A static pitot probe was installed on a boom 2.3 m upwind of the nacelle at hub height and connected to the reference side of the Mensor digital differential pressure transducer through the pneumatic rotary coupling. This provided the reference pressure for all blade-mounted pressure transducers, as opposed to the NASA atmospheric pressure reference that was used for all other test sequences. This simulates the pressure system connections used in field measurements where the static pressure was unknown.

17 WIND ENERGY↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy

Due to its nonlinear nature, the supply fan at air handling units with the controller tuned at the design condition tends to be aggressive and oscillate under partial load conditions. Here, the objective of this paper is to develop and validate a gain scheduling control strategy to improve its nonlinear control performance. First, a control-oriented model, which does not require numerous physical parameters and extensive test data, is developed to study the nonlinearity of the fan system. Based on the theoretical model and experimental verifications, the issue of an aggressive response with a conventional fixed-gain controller is caused by the fact that the system gain is proportional to the ratio of the duct static pressure to the fan speed. To address the issue, a scheduling function of the measurable duct static pressure and fan speed is proposed to be included in the conventional fixed-gain controller to compensate for the fan system gain variation. The gain scheduling control strategy is found to approximately maintain the identical control performance under all operation conditions. Most importantly, the gain scheduling control strategy can be readily implemented without intensive computation and additional measurements, showing a promising potential in industrial applications.

42 ENGINEERING↗

Performance Characteristics of a Rotating Detonation Combustor Exiting Into a Pressurized Plenum to Simulate Gas Turbine Inlet

Abstract The present study aims to experimentally characterize the performance of a rotating detonation combustion (RDC) system integrated with a pressurized downstream plenum to simulate the high-pressure inlet conditions of power-generating gas turbines. A thorough understanding of the operational behavior including wave mode behavior, static pressure profile along the combustor length, and dynamic features of pressure fluctuations is crucial for successful integration of RDC with the turbine. In this study, two RDC configurations are investigated, RDC with a constant area annulus and RDC with a converging nozzle. In both cases, the RDC flow exited into a plenum chamber kept at pressures varying from 155 kPa to 330 kPa. RDC was operated on methane and oxygen-enriched air to represent reactants used in land-based power generation. Experiments were conducted for the two RDCs configurations operated at three reactant mass flow rates (0.23, 0.32, and 0.46 kg/s). The RDC performance is characterized by time-averaged static pressure measurements, and wave velocity determined by ionization probes. In addition, dynamic pressure measurements were recorded both inside and near the exit of RDC channel to investigate wave interactions between RDC and downstream plenum. Results show that the RDC with the converging nozzle achieved superior performance while minimizing detrimental interactions with the reflected shock and/or acoustic waves from the downstream plenum.

Engineering↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Universal diamond edge Raman scale to 0.5 terapascal and implications for the metallization of hydrogen

The recent progress in generating static pressures up to terapascal values opens opportunities for studying novel materials with unusual properties, such as metallization of hydrogen and high-temperature superconductivity. However, an evaluation of pressure above ~0.3 terapascal is a challenge. We report a universal high-pressure scale up to ~0.5 terapascal, which is based on the shift of the Raman edge of stressed diamond anvils correlated with the equation of state of Au and does not require an additional pressure sensor. According to the new scale, the pressure values are substantially lower by 20% at ~0.5 terapascal compared to the extrapolation of the existing scales. We compare the available data of H 2 at the highest static pressures. We show that the onset of the proposed metallization of molecular hydrogen reported by different groups is consistent when corrected with the new scale and can be compared with various theoretical predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗