Search NASA⌕ Search

SEARCH · Search NASA

Results for “Station occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating system responses to electric vehicle charging infrastructure expansion through data-driven simulation

Understanding the system responses to electric vehicle (EV) charging infrastructure expansion, including vehicle charging needs, station utilization, and energy consumption, is critical for effective planning to meet growing charging demand without unnecessary resource investment. This study evaluates the system responses to EV charging infrastructure expansion, focusing on charging needs, station utilization, and energy consumption. Using trip data from the National Household Travel Survey and origin–destination patterns, we simulated trip chains in downtown Atlanta with 10 % EV penetration. We assessed 32 scenarios involving different charging port power levels and siting strategies. Furthermore, we found that higher-power ports were more sensitive to placement, with concentrated expansion boosting station utilization more than uniform expansion. Adding high-power ports did not always increase peak energy consumption; in some cases, a few 400 kW ports reduced overall consumption compared to 150 kW ports by enabling faster charging and higher vehicle turnover.

Electric vehicle↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Cylinder Occupancy and Measurement Suite

This software automatically records data from the Unattended Cylinder Verification Station, determines the state of the instrument, captures images of uranium hexafluoride shipment cylinders, and determines their weight. The code has been developed primarily for the International Atomic Energy Agency, but this type of instrument could be of interest to any facility operator in the uranium supply chain that handles uranium hexafluoride shipment cylinders (e.g. the 30B and 48Y cylinder). Operators may be interested in having this instrument confirm shipper declared measurement values upon receipt of a cylinder. They may also use it to aid in process monitoring if the quantity of material in the cylinder changes due to a processing activity.

Stewart, Scott L↗

Panel Session 4 and 15: Japan Fukushima Daiichi D and D Update and Technological Challenges at Japan Fukushima Daiichi D and D and Update on Nuclear Overview and Development in Japan - Nuclear Fuel Cycle

Sessions 4 and 15 represent a two-part panel series that discusses progress and challenges associated with cleanup at Fukushima. Severe limitations on availability of original panelists from Japan due to strict restrictions put in place to alleviate the spread of coronavirus necessitated changes to both panels. The result was a significantly modified panel for Session 04 (shown above) and the elimination of all panelists for Session 15. The 4 and 15 Panel Sessions provide an overview of activities related to both the progress and challenges of cleanup and decommissioning of the Fukushima Daiichi Nuclear Power Station (NPS) in Japan. Five panelists discussed perspectives of the cleanup following a Tokyo Electric Power Company (TEPCO) video showing the progress on site since the devastating Great East Earthquake and tsunami that caused the explosions at three of the six reactors on the site. Three of the five panelists discussed on-going work being performed for the effort, while the other two provided expert perspectives of on strategic efforts at the site. The panel was attended by over 80 technologists and policy makers spanning the globe and was opened by Dr. Monica Regalbuto of Idaho National Laboratory and a short video provided by TEPCO. The video described changes at the site that spanned the cleanup efforts from stabilizing water intrusion into the contaminated reactor buildings to construction of new administrative facilities. The video explained the processes underway to retrieve spent fuel rods and challenges in retrieval of the compromised fuel debris. The video highlighted working condition improvements that included establishment of rest housing and a small convenience store on the site, and the rollback of protective equipment around the site due to decreases contamination. Panelists with presentations: Revision of 'the Mid-and-Long-Term Road-map towards the Decommissioning of TEPCO's Fukushima Daiichi Nuclear Power Station' (Paul Dickman); Sharing UK experience at Fukushima Daiichi (Adrian Simper); SRNL Japan (Andrew Fellinger); ABLE's Initiative to Dismantle the Exhaust Stack (Daniel Walter); JAEA R and D in Fukushima (Tokio Fukahori); TEPCO - Overview and Update of the Fukushima Decommissioning Process (Monica Regalbuto); Toshiba's Involvement in the Decommissioning of the Fukushima Daiichi Nuclear Power Plant (Yasuhiro Yuguchi); Remote Dismantling of the Exhaust Stack At Fukushima Dai-ichi NPS (Takashi Okutsu)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Shared Automated Vehicles for First-Mile Last-Mile Service: Micro-Simulation of Rail-Transit Connections in Austin, Texas

Shared fleets of fully automated vehicles (SAVs) coupled with real-time ride-sharing to and from transit stations are of interest to cities and nations in delivering more sustainable transportation systems. By providing first-mile last-mile (FMLM) connections to key transit stations, SAVs can replace walk-to-transit, drive-to-transit, and drive-only trips. Using the SUMO (Simulation of Urban MObility) toolkit, this paper examines mode splits, wait times, and other system features by micro-simulating two fleets of SAVs providing an FMLM ride-sharing service to 10% of central Austin’s trip-makers near five light-rail transit stations. These trips either start or end within two geofenced areas (called automated mobility districts [AMDs]), and travel time and wait time feedbacks affect mode choices. With rail service headways of 15?min, and 15 SAVs serving FMLM connections to and from each AMD, simulations predict that 3.7% of the person-trip-making will shift from driving alone to transit use in a 3?mi?×?6?mi central Austin area. During a 3-h morning peak, 30 SAVs serve about 10 person-trips each (to or from the stations), with 3.4?min average wait time for SAVs, and an average vehicle occupancy of 0.74 persons (per SAV mile-traveled), as a result of empty SAV driving between riders. Sensitivity analysis of transit headways (from 5 to 20?min) and fleet sizes (from 5 to 20 vehicles in each AMD) shows an increase in FMLM mode share with more frequent transit service and larger fleet size, but total travel time served as the biggest determinant in trip-makers’ mode share.

47 OTHER INSTRUMENTATION↗

Bottleneck Detection in Modular Construction Factories Using Computer Vision

The construction industry is increasingly adopting off-site and modular construction methods due to the advantages offered in terms of safety, quality, and productivity for construction projects. Despite the advantages promised by this method of construction, modular construction factories still rely on manually-intensive work, which can lead to highly variable cycle times. As a result, these factories experience bottlenecks in production that can reduce productivity and cause delays to modular integrated construction projects. To remedy this effect, computer vision-based methods have been proposed to monitor the progress of work in modular construction factories. However, these methods fail to account for changes in the appearance of the modular units during production, they are difficult to adapt to other stations and factories, and they require a significant amount of annotation effort. Due to these drawbacks, this paper proposes a computer vision-based progress monitoring method that is easy to adapt to different stations and factories and relies only on two image annotations per station. In doing so, the Scale-invariant feature transform (SIFT) method is used to identify the presence of modular units at workstations, and the Mask R-CNN deep learning-based method is used to identify active workstations. This information was synthesized using a near real-time data-driven bottleneck identification method suited for assembly lines in modular construction factories. This framework was successfully validated using 420 h of surveillance videos of a production line in a modular construction factory in the U.S., providing 96% accuracy in identifying the occupancy of the workstations and an F-1 Score of 89% in identifying the state of each station on the production line. The extracted active and inactive durations were successfully used via a data-driven bottleneck detection method to detect bottleneck stations inside a modular construction factory. The implementation of this method in factories can lead to continuous and comprehensive monitoring of the production line and prevent delays by timely identification of bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-occurrence of native white-tailed deer and invasive wild pigs: Evidence for competition?

Understanding whether invasive and native species compete for shared resources where they co-occur is essential for mitigating the negative impacts of invasive species on native ecosystems. Here, we examined how the presence and density of an invasive species, wild pigs (Sus scrofa), affect native white-tailed deer (Odocoileus virginianus; hereafter, deer) on the Savannah River Site, SC, USA. We examined potential changes in deer areas of use, temporal overlap, and occupancy to evaluate the effects of wild pig occurrence and density on deer space use, diel activity, and co-occurrence with wild pigs across 9 months during 2018 and 2019. Wild pig density had the strongest effect on deer space use in high- and moderate-use areas. Declines in deer space use in response to wild pig density were most pronounced in March and October 2018 and April 2019 for females, while male space use declined in response to wild pig density in October and December 2018. Both species were largely nocturnal with high overlap in diel activity across months. Deer occupancy responses to wild pig density varied across months, with negative responses in May and October 2018 and positive responses in July 2018 and April 2019. Deer and wild pigs co-occurred at 30%–59% of camera stations across months, with broadscale co-occurrence patterns being unaffected by changes in shared cover or wild pig occurrence. Overall, our results suggest that deer make fine-scale behavioral adjustments to avoid wild pigs, providing evidence that competition is likely occurring even where wild pig density is relatively low. Such fine-scale behavioral plasticity in deer appears to mitigate the costs of competition with wild pigs and may be a mechanism enabling long-term co-existence of deer and wild pigs. Our study provides novel insight on the complexities of spatiotemporal relationships between invasive wild pigs and native deer and suggests that the negative effects of interactions between deer and wild pigs may be more pronounced when deer life history needs are particularly demanding. In areas where eradication of invasive wild pigs may be impossible, maintaining low wild pig densities may help mitigate, but may not eliminate, the negative effects of wild pigs on deer.

resource partitioning↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HIVE™ [SWR-19-36]

The HIVE™ platform is a mobility services simulation platform developed to provide insight on the energy, infrastructure, service, and economic outcomes of various mobility as a service (MaaS) options. The HIVE platform takes a set of spatiotemporal travel origin-destination pairs and simulates the operation of a predefined mobility service fleet, incorporating request pooling, and various operational and charging behaviors. Hive specializes at modeling fleets of automated electric vehicles (AEVs) and can be used to site and size direct current fast charge (DCFC) stations and measure grid impacts of large-scale AEV fleets serving real-world MaaS trip demand (similar to taxis, Uber, Lyft, etc.). Potential outcomes from a Hive simulation include level of service, total vehicle miles traveled (VMT), deadheading (zero passenger) miles, simultaneous and total energy loads, average occupancy, and more. Hive is developed to generalize to new regions and can be customized to handle many scenarios and operating conditions.

Rames, Clement↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Secure mmWave Spectrum Sharing with Autonomous Beam Scheduling for 5G and Beyond

Spectrum Sharing (SS) has seen a renewed set of initiatives in 5G with the availability of shared and unlicensed spectrum bands that can be used by multiple cellular service providers and private cellular networks. Beam based transmission, instead of the traditional sector based transmission in conjunction with the spectrum agility of the 5G New Radio (NR) has brought new opportunities to optimized sharing of spectrum. Currently in the U.S., a centralized Spectrum Access Server (SAS) is used to co-ordinate spectrum sharing among networks sharing the same spectrum band. However, SAS becomes a focal point for security attacks and a performance bottleneck. In addition, SAS relies on an Environmental Sensor Network (ESN), separate from the 5G network. Without trusted spectral occupancy information, false reporting of spectrum sensing data can create sub-optimal and unfair spectrum usage. This paper summarizes our recent research findings in using a decentralized scheme for multiple networks to securely share spectrum with autonomous beam scheduling : 1) A new stochastic network framework based on Lyapunov Optimization approach is developed to optimize scheduling at the base stations; 2) Game theoretic (GT) approach is used to formulate the distributed scheduler; 3) Another distributed scheduler with Q-learning is presented that utilizes the Reinforcement Learning (RL) approach; 4) The performance and convergence rate of these distributed solutions to use shared and unlicensed spectrum are compared with existing solutions. Conditions under which the performance of these schedulers approach the theoretical upper bound, which is the performance possible with no interference among the operators sharing the spectrum, are presented; 5) The ability of a base station to use its own user equipment as sensors, for optimal spectrum sharing with base stations in other operator networks, is demonstrated to be an effective approach.

5G↗

Learning electric vehicle driver range anxiety with an initial state of charge-oriented gradient boosting approach

This manuscript focuses on the modeling of electric vehicle (EV) driver’s range anxiety, a fear that a vehicle does not have sufficient range, or state of charge (SOC) of the battery pack, to reach its destination and would strand its occupants. Despite numerous research studies on the modeling of charging behaviors, modeling efforts to understand at what battery percentages do EV drivers charge their vehicles, and what are the associated contributing factors, are rather limited. To this end, an ensemble learning model based on gradient boosting is developed. The model sequentially fits new predictors to new residuals of the previous prediction and, then, minimizes the loss when adding the latest prediction. A total of 18 features are defined and extracted from the multisource data, which cover information on driver, vehicles, stations, traffic conditions, as well as spatial-temporal context information of the charging events. The analyzed dataset includes 4.5-year’s charging event log data from 3,096 users and 468 public charging stations in Kansas City Missouri, and the macroscopic travel demand model maintained by the metropolitan planning organization. Here, the result shows the proposed model achieved a satisfactory result with a R square value of 0.54 and root mean square error of 0.14, both better than multiple linear regression model and random forest model. To reduce range anxiety, it is suggested that the priorities of deploying new charging facilities should be given to the areas with higher daily traffic prediction, with more conservative EV users or that are further from residential areas.

33 ADVANCED PROPULSION SYSTEMS↗