Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistics, MCNP, MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

(U) A General-Purpose Code for Correlated Sampling Using Batch Statistics with MCNP6 for Fixed-Source Problems

Correlated sampling can be used to reduce the uncertainty of a difference of tallies by taking advantage of the negative covariance term in the sandwich formula. Booth first showed how correlated sampling can be applied with batch statistics using MCNP’s tally fluctuation chart (TFC) to reduce the uncertainty of a difference of tallies in fixed-source problems. Booth presented a problem in which a 1273% uncertainty in a difference was reduced to 8% by accounting for correlations. Researchers He and Su recently studied correlated sampling using the TFC in MCNP version 5. They determined that the code did not print enough digits in the TFC tally means for accurate batch statistics in some cases. After modifying the source code, they concluded that “correlated sampling can yield a standard deviation of about one magnitude smaller than that predicted by the direct, un-correlated simulation when the changes in system response are small (say about 1%), which is equivalent to saving in CPU time by a factor of 100. Such saving [sic] becomes less significant as the change in system response becomes larger.” He and Su provided the formulas needed to apply batch statistics to compute the correlated uncertainty of a difference of tallies. In this report, we follow up on their work by providing the formulas needed to apply batch statistics to compute the correlated uncertainty of a ratio of tallies and of a difference of two tallies divided by a third tally. We extend these formulas to differences and ratios of ratios. These formulas are applied to reduce the uncertainty associated with calculating a relative sensitivity. He and Su did not investigate the accuracy of their correlated sampling uncertainty estimates. We use their test problems and evaluate the accuracy of the uncertainty estimates by comparing with results obtained from random sampling, and, in simple cases, with theoretical values of the “exact” uncertainties. We find that the uncertainties obtained from batch statistics are accurate as long as at least 100 batches are used. We present a new computer code, COSUBS (COrrelated Sampling Using Batch Statistics), that reads MCNP6 TFCs and applies correlated sampling using batch statistics for the tally combinations that the user specifies. COSUBS is a very general tool that compares all TFCs for a base case and one or two perturbed cases. It computes uncertainties for ratios if given only a base case. This report is organized as follows. The equations to apply batch statistics to the difference of random tallies are reviewed in Sec. II. Section III presents the equations for applying batch statistics to a ratio of random tallies; this is useful for computing relative sensitivities using a one-sided finite difference and the relative sensitivity using the differential operator method. Section IV presents the equations for applying batch statistics to a difference of two random tallies divided by a third; this is useful for computing a relative sensitivities using a central difference. Section V presents the equations for applying batch statistics to a difference of two ratios with four random tallies. Section VI presents the equations for applying batch statistics to a one-sided finite difference estimate of the relative sensitivity of a ratio (this uses four random tallies). Section VII presents the equations for applying batch statistics to a central difference estimate of the relative sensitivity of a ratio (this uses six random tallies). Section VIII presents the equations for applying batch statistics to a sum of random tallies. Section IX discusses how to apply batch statistics using MCNP6. Section X presents COSUBS, describing its command-line options and logic. Sections XI through XVI present numerical results for various test problems. Section XVII is a summary and conclusions. Appendix A derives the theoretical Monte Carlo tally variance given certain assumptions; these variances are used to verify the batch statistics for some of the problems. Appendix B lists the MCNP6 input for the unperturbed example problem. Appendix C presents modifications made to MCNP6.3 to support this work.

97 MATHEMATICS AND COMPUTING↗

Adjoint-Based Uncertainty Quantification with MCNP

This work serves to quantify the instantaneous uncertainties in neutron transport simulations born from nuclear data and statistical counting uncertainties. Perturbation and adjoint theories are used to derive implicit sensitivity expressions. These expressions are transformed into forms that are convenient for construction with MCNP6, creating the ability to perform adjoint-based uncertainty quantification with MCNP6. These new tools are exercised on the depleted-uranium hybrid LIFE blanket, quantifying its sensitivities and uncertainties to important figures of merit. Overall, these uncertainty estimates are small (< 2%). Having quantified the sensitivities and uncertainties, physical understanding of the system is gained and some confidence in the simulation is acquired.

42 ENGINEERING↗

MCNP6 Status and plans for criticality safety applications - 14368

The first production version of MCNP6 was released in 2013, with an update in 2014. MCNP6 provides all of the standard methodology for criticality calculations available in previous versions and new capabilities for adjoint-based sensitivity profiles and perturbations. This paper reviews the current status of MCNP6, including new features, performance improvements, verification testing, and nuclear data libraries. For criticality safety support, a new statistical package called Whisper was developed and first applied in 2014 for validation and determining USLs. Whisper includes input files and sensitivity profiles for over 1000 ICSBEP benchmarks and will be distributed with MCNP6. For the long term, an initiative called MCNP 2020 is underway to improve performance, strengthen the code foundation, and prepare for future computer systems. (authors)

42 ENGINEERING↗

Release of MCNP6.2 and WHISPER-1.1 - Guidance for NCS users

In 2017, a new version of the MCNP6 Monte Carlo code package was released: MCNP6.2. This is the first version of MCNP to include the WHISPER package to support sensitivity-uncertainty based nuclear criticality safety validation. The coding changes to MCNP6.2 physics are relatively insignificant. Corrections to the S(α,β) thermal scattering numerics are generally negligible relative to problem statistics (or, in rare cases, prevent aborts). Similarly, the changes to adjoint-weighting for computing kinetics parameters may result in small differences, generally negligible compared to problem statistics. The change to the MCNP6.2 geometry treatment to correctly handle coincident surfaces in problems with universe/fill features will produce different round-off in the geometry tracking. This will produce differences in results relative to previous versions, but those differences should be small relative to problem statistics, and are not a concern. An immediate benefit of using MCNP6.2 (rather than MCNP6.1) is that the new version is typically 1.5-2 times faster.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation

These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such as MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

User Manual for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015- 2016, Whisper was updated to version 1.1 and is to be included with the upcoming release of MCNP6.2. This document describes the user input and options for running whisper-1.1, including 2 perl utility scripts that simplify ordinary NCS work, whisper_mcnp.pl and whisper_usl.pl. For many detailed references on the theory, applications, nuclear data & covariances, SQA, verification-validation, adjointbased methods for sensitivity-uncertainty analysis, and more – see the Whisper – NCS Validation section of the MCNP Reference Collection at mcnp.lanl.gov. There are currently over 50 Whisper reference documents available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Creation of a Benchmark Suite for SNL Nuclear Criticality Safety Code Validation (Volume 1 - MCNP)

The Nuclear Criticality Safety Program at Sandia National Laboratories has developed a suite of benchmark problems to be utilized for validation of MCNP6 Version 1.0 with ENDF/B-VII Release 1 cross sections. The benchmark suite covers a broad range of fissile material types, material forms, moderators, reflectors, and neutron energy spectra. It is anticipated that this benchmark suite will cover the vast majority of critical safety applications at SNL. The benchmark suite establishes a Bias and Bias Uncertainty for use in criticality safety analyses. In addition, the Bias and Bias Uncertainty value derived from the benchmark suite using the traditional SNL NCS methodology is demonstrated to be equivalent to the more robust statistical techniques used at many DOE sites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating Region-wise Sensitivities for Nuclear Criticality Safety Validation

Whisper is a criticality safety statistical analysis package that uses the sensitivity profile data developed by MCNP6 for a given application and the covariance files for the nuclear data to determine a baseline Upper-Subcritical-Limit (USL) for a given application [1]. Whisper is designed to give a quantifiable basis for the selection of criticality benchmarks used to determine the appropriate calculational margin.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release Notes for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015-2016, Whisper was updated to version 1.1 [9] and is to be included with the upcoming release of MCNP6.2. This document describes the Whisper-1.1 package that will be included with the MCNP6.2 release during 2017. Specific details are provided on the computer systems supported, the software quality assurance (SQA) procedures, installation, and testing. This document does not address other important topics, such as the importance of sensitivity-uncertainty (SU) methods to NCS validation, the theory underlying SU methodology, tutorials on the usage of MCNP-Whisper, practical approaches to using SU methodology to support and extend traditional validation, etc. There are over 50 documents included with Whisper-1.1 and available in the MCNP Reference Collection on the MCNP website (mcnp.lanl.gov) that address all of those topics and more. In this document, however, a complete bibliography of relevant MCNP-Whisper references is provided.

97 MATHEMATICS AND COMPUTING↗

Neutron and Gamma Correlations using CGM in MCNP 6.2.0

The general-purpose Monte Carlo radiation-transport code MCNP6{sup TM} came from the integration of MCNP5{sup TM} and MCNPX{sup TM}. The most recent release of MCNP, version 6.2.0, is scheduled for release in early 2017, which includes a variety of bug fixes and new features to the code. MCNP traditionally models nuclear reactions using Monte Carlo sampling techniques on measured and modeled cross-sectional data contained within ACE (A Compact Evaluated Nuclear Data File) libraries. In addition to reaction cross-sections, ACE libraries contain information relating to the production of secondary particles, such as secondary neutrons and photons. For example, an incident neutron on a nucleus can produce a nuclear reaction in the form (n, M{sub n}n'), where n is the incident neutron and M{sub n} is the number of secondary neutrons n' produced. Using this notation, different reactions can be described based on their neutron multiplicity, such as neutron capture (M{sub n} = 0), elastic and inelastic scattering (M{sub n} = 1), and reactions with multiple secondary neutrons (M{sub n} > 1). Accounting for secondary γ-rays emitted from the residual nuclei, this reaction can further be generalized as n, Mnn'M to describe a reaction producing M{sub n} neutrons and M -rays. These values M{sub n} and M are referred to as the neutron and multiplicities, respectively. ACE libraries contain the cross-sectional data for each reaction, and their corresponding statistically averaged multiplicities for neutrons and photons, M-bar{sub n} and M-bar{sub γ}. However, there are several limitations to reaction sampling using ACE libraries. First, the data contained within ACE libraries is limited by the accuracy of the model and/or experiment, which out of necessity can greatly simplify the true physics behind a reaction. For example, the value M{sub γ} in a (n, M{sub n}n'M{sub γ}γ) reaction is determined by the statistically averaged multiplicity M-bar{sub γ} instead of a distribution. Consequently, MCNP, unable to produce a continuous distribution, will utilizes a binary sampling around M-bar{sub γ}. While this sampling method provides a statistically average M{sub γ} over a large simulation, it is an inaccurate representation of an individual reaction and its corresponding secondary particles. Secondary neutrons are affected in a similar manner, such that different kinds of secondary neutrons can be sampled from the same interaction (eg., an inelastic neutron with an [n, 2n] neutron). Lastly, the random sampling technique for secondary particles remains completely independent of the sampled reaction, eliminating the ability to correlate secondary particles for a given reaction. To supplement these data libraries, additional codes and models describing certain nuclear reactions are employed. These codes can fill in the information missing from ACE, provide a better model to the true physics distribution, and can provide true correlated secondary particles, which has many useful applications in research and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗